Effects of Fe addition on the mechanical and corrosive properties of biomedical Co-Cr-W-Ni alloys for balloon-expandable stents

被引:0
|
作者
Ueki, Kosuke [1 ]
Hida, Akira [1 ]
Nakai, Masaaki [1 ]
机构
[1] Kindai Univ, Dept Mech Engn, 3-4-1 Kowakae, Higashiosaka 5778502, Japan
基金
日本学术振兴会;
关键词
Co-Cr-W-Ni alloy; Fe addition; Stacking fault energy; Strain-induced martensitic transformation; Precipitates; Mechanical properties; Corrosive properties; STACKING-FAULT-ENERGY; STRENGTHENING MECHANISMS; MP35N ALLOY; MICROSTRUCTURE; TEMPERATURE; BEHAVIOR; MN; STEELS; TRANSFORMATION; IMPROVEMENT;
D O I
10.1016/j.jmbbm.2024.106714
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Co-20Cr-15W-10Ni (mass%, CCWN) alloy is extensively used as a platform material for balloon-expandable stents. In this study, the mechanical properties of CCWN alloy are improved following the addition of Fe, and the effects of Fe addition on the mechanical and corrosive properties of the alloy are investigated. As-cast specimens were fabricated by adding pure Fe to a commercially available CCWN alloy (base alloy) such that the resulting alloys contained 4, 6, and 8 mass% Fe. The as-cast specimens were subjected to homogenization heat treatment at 1523 K for 7.2 ks and then hot-forged at 1473 K (as-forged specimens). The as-forged specimens were cold-rolled at a reduction rate of 30% and heat-treated at 1473 K for 300 s (recrystallized specimens). The matrix of the recrystallized base- and Fe-containing alloys consisted of a single gamma (face-centered cubic)-phase. The Fe-added alloys revealed precipitates composed of the eta-phase (M6X-M12X-type phase, M: metallic element, X: C and/or N). The average grain size of the recrystallized base and Fe-added alloy specimens was approximately 34 mu m and the amount of added Fe had no significant effect on the static recrystallization behavior of the resulting alloys. Alloys containing 6 mass% or more Fe showed improvements in strength and ductility compared with the base alloy. When the Fe-added alloys were compared, their strength decreased whereas their ductility increased when the added Fe increased. Because Fe acts as a gamma-phase-stabilizing element for Co, Fe addition increases the stacking fault energy of the base alloy, resulting in the formation of the epsilon (hexagonal close-packed)-phase owing to the suppression of strain-induced martensitic transformation (SIMT), and improvements in ductility. No deterioration in corrosion resistance was observed following the addition of up to 8 mass% Fe to the base alloy. Based on these results, the addition of Fe to CCWN alloy may be considered an effective method to improve its mechanical properties, especially ductility, without impairing its corrosion resistance. The results of this study will be useful for the future development of Ni-free Co-Cr alloys for next-generation, small-diameter stents.
引用
收藏
页数:8
相关论文
共 50 条
  • [22] Effect of Fe addition on microstructures and mechanical properties of Ni- and C-free Co-Cr-Mo alloys
    Lee, Sang-Hak
    Nomura, Naoyuki
    Chiba, Akihiko
    MATERIALS TRANSACTIONS, 2007, 48 (08) : 2207 - 2211
  • [23] Effect of boron microalloying on the microstructure, mechanical, and corrosion properties of as-cast biomedical Co-Cr-W-Ni-based alloys
    Maulana, Muhammad Ilham
    Syahid, Adi Noer
    Elvira, Bunga Rani
    Erryani, Aprilia
    Thaha, Yudi Nugraha
    Rokhmanto, Fendy
    Mori, Manami
    Yamanaka, Kenta
    Korda, Akhmad Ardian
    Kartika, Ika
    Setyawan, Albertus Deny Heri
    JOURNAL OF MATERIALS RESEARCH, 2024, 39 (16) : 2272 - 2285
  • [24] Biomedical Co-Cr-Ni and Co-Cr-Mo alloys properties comparison
    Matkovic, P
    Matkovic, T
    Malina, J
    STROJARSTVO, 2003, 45 (1-3): : 5 - 10
  • [25] Specific Features of Microstructure Formation in Co–Cr–Ni–W–Ta Alloys and Their Mechanical Properties
    I. S. Mazalov
    D. I. Suhov
    S. V. Nerush
    E. A. Sulyanova
    Crystallography Reports, 2019, 64 : 575 - 580
  • [26] Development of new Co-Cr-W-based biomedical alloys: Effects of microalloying and thermomechanical processing on microstructures and mechanical properties
    Yamanaka, Kenta
    Mori, Manami
    Kuramoto, Koji
    Chiba, Akihiko
    MATERIALS & DESIGN, 2014, 55 : 987 - 998
  • [27] Influence of carbon addition on mechanical properties and microstructures of Ni-free Co-Cr-W alloys subjected to thermomechanical processing
    Yamanaka, Kenta
    Mori, Manami
    Chiba, Akihiko
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2014, 37 : 274 - 285
  • [28] Influence of Fe on Microstructure and Mechanical Properties in Pdoped Ni–Cr–Fe Alloys
    Xin-Tong Lian
    Wen-Ru Sun
    Xin Xin
    Fang Liu
    Dan-Dan Zheng
    ActaMetallurgicaSinica(EnglishLetters), 2019, 32 (06) : 771 - 779
  • [29] Microstructure, texture and mechanical properties of hot rolled and annealed Ni-Fe-W and Ni-Fe-W-Co matrix alloys
    Rao, A. Sambasiva
    Manda, Premkumar
    Mohan, M. K.
    Nandy, T. K.
    Singh, A. K.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2018, 742 : 937 - 951
  • [30] Effect of minor Cr additions on microstructure and mechanical properties of 93W-Ni-Fe alloys
    State Key Laboratory of Powder Metallurgy, Central South University, Changsha 410083, China
    Zhongguo Youse Jinshu Xuebao, 2008, 9 (1645-1650):