Effects of Fe addition on the mechanical and corrosive properties of biomedical Co-Cr-W-Ni alloys for balloon-expandable stents

被引:0
|
作者
Ueki, Kosuke [1 ]
Hida, Akira [1 ]
Nakai, Masaaki [1 ]
机构
[1] Kindai Univ, Dept Mech Engn, 3-4-1 Kowakae, Higashiosaka 5778502, Japan
基金
日本学术振兴会;
关键词
Co-Cr-W-Ni alloy; Fe addition; Stacking fault energy; Strain-induced martensitic transformation; Precipitates; Mechanical properties; Corrosive properties; STACKING-FAULT-ENERGY; STRENGTHENING MECHANISMS; MP35N ALLOY; MICROSTRUCTURE; TEMPERATURE; BEHAVIOR; MN; STEELS; TRANSFORMATION; IMPROVEMENT;
D O I
10.1016/j.jmbbm.2024.106714
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Co-20Cr-15W-10Ni (mass%, CCWN) alloy is extensively used as a platform material for balloon-expandable stents. In this study, the mechanical properties of CCWN alloy are improved following the addition of Fe, and the effects of Fe addition on the mechanical and corrosive properties of the alloy are investigated. As-cast specimens were fabricated by adding pure Fe to a commercially available CCWN alloy (base alloy) such that the resulting alloys contained 4, 6, and 8 mass% Fe. The as-cast specimens were subjected to homogenization heat treatment at 1523 K for 7.2 ks and then hot-forged at 1473 K (as-forged specimens). The as-forged specimens were cold-rolled at a reduction rate of 30% and heat-treated at 1473 K for 300 s (recrystallized specimens). The matrix of the recrystallized base- and Fe-containing alloys consisted of a single gamma (face-centered cubic)-phase. The Fe-added alloys revealed precipitates composed of the eta-phase (M6X-M12X-type phase, M: metallic element, X: C and/or N). The average grain size of the recrystallized base and Fe-added alloy specimens was approximately 34 mu m and the amount of added Fe had no significant effect on the static recrystallization behavior of the resulting alloys. Alloys containing 6 mass% or more Fe showed improvements in strength and ductility compared with the base alloy. When the Fe-added alloys were compared, their strength decreased whereas their ductility increased when the added Fe increased. Because Fe acts as a gamma-phase-stabilizing element for Co, Fe addition increases the stacking fault energy of the base alloy, resulting in the formation of the epsilon (hexagonal close-packed)-phase owing to the suppression of strain-induced martensitic transformation (SIMT), and improvements in ductility. No deterioration in corrosion resistance was observed following the addition of up to 8 mass% Fe to the base alloy. Based on these results, the addition of Fe to CCWN alloy may be considered an effective method to improve its mechanical properties, especially ductility, without impairing its corrosion resistance. The results of this study will be useful for the future development of Ni-free Co-Cr alloys for next-generation, small-diameter stents.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Significant improvement in mechanical properties of biomedical Co-Cr-Mo alloys with combination of N addition and Cr-enrichment
    Lee, Sang-Hak
    Nomura, Naoyuki
    Chiba, Akihiko
    MATERIALS TRANSACTIONS, 2008, 49 (02) : 260 - 264
  • [32] Strain-induced martensitic transformation in biomedical Co–Cr–W–Ni alloys
    Zi-Yi Zhu
    Li Meng
    Leng Chen
    Rare Metals, 2020, 39 : 241 - 249
  • [33] Effect of Nitrogen Addition on Isothermal Phase Transformation and Mechanical Properties in Biomedical Co-Cr-Mo Alloys
    Kurosu, Shingo
    Matsumoto, Hiroaki
    Chiba, Akihiko
    TMS 2010 139TH ANNUAL MEETING & EXHIBITION - SUPPLEMENTAL PROCEEDINGS, VOL 3: GENERAL PAPER SELECTIONS, 2010, : 707 - 714
  • [34] STRUCTURAL-PROPERTIES OF TUNGSTEN-BASED SINTERED ALLOYS - W-NI-FE, W-NI-CO AND W-NI-CR
    MARGARIA, T
    ALLIBERT, C
    DRIOLE, J
    JOURNAL OF THE LESS-COMMON METALS, 1977, 53 (01): : 85 - 95
  • [35] Specific Features of Microstructure Formation in Co-Cr-Ni-W-Ta Alloys and Their Mechanical Properties
    Mazalov, I. S.
    Suhov, D. I.
    Nerush, S. V.
    Sulyanova, E. A.
    CRYSTALLOGRAPHY REPORTS, 2019, 64 (04) : 575 - 580
  • [36] Effects of in situ composite ceramics on the mechanical properties and microstructure of Fe-Cr-Ni alloys
    Chen, Chang
    Shi, Sitao
    Fang, Litong
    Song, Qiang
    Jiu, Shaowu
    Chen, Yanxin
    Yang, Jianfeng
    MATERIALS LETTERS, 2024, 363
  • [37] Effects of Nb on hot tensile deformation behavior of cast Haynes 25 Co-Cr-W-Ni alloy
    Zafarghandi, Mandi Samii
    Abbasi, Seyed Mandi
    Momeni, Amir
    JOURNAL OF ALLOYS AND COMPOUNDS, 2019, 774 : 18 - 29
  • [38] Effects of Cr/Ni ratio on physical properties of Cr-Mn-Fe-Co-Ni high-entropy alloys
    Wagner, Christian
    Ferrari, Alberto
    Schreuer, Jurgen
    Couzinie, Jean-Philippe
    Ikeda, Yuji
    Koermann, Fritz
    Eggeler, Gunther
    George, Easo P.
    Laplanche, Guillaume
    ACTA MATERIALIA, 2022, 227
  • [39] Effects of cold drawing and annealing on mechanical properties and microstructure of Co-Cr-Mo-Ni-Fe alloys for surgical implants
    Okazaki, Yoshimitsu
    MATERIALS TRANSACTIONS, 2008, 49 (07) : 1656 - 1660
  • [40] Microstructural, Mechanical, And Corrosion Behaviour of Ni-Fe-Cr-Al and Ni-Fe-Cr-Al-Co Alloys
    Kar, Shubhada
    Meena, L. K.
    Srivastava, V. C.
    Mandal, G. K.
    TRANSACTIONS OF THE INDIAN INSTITUTE OF METALS, 2024, 77 (05) : 1299 - 1311