The biomechanical effect of lumbopelvic distance reduction on reconstruction after total sacrectomy: a comparative finite element analysis of four techniques

被引:0
|
作者
Turbucz, Mate [1 ,2 ]
Pokorni, Agoston Jakab [1 ,2 ]
Hajnal, Benjamin [1 ,2 ]
Koch, Kristof [1 ,3 ]
Szoverfi, Zsolt [3 ]
Varga, Peter Pal [3 ]
Lazary, Aron [3 ,4 ]
Eltes, Peter Endre [2 ,3 ,4 ]
机构
[1] Semmelweis Univ, Sch PhD Stud, Ulloi Str 26, Budapest, Hungary
[2] Natl Ctr Spinal Disorders, In Sil Biomech Lab, Kiralyhago Str 1-3, Budapest, Hungary
[3] Natl Ctr Spinal Disorders, Kiralyhago Str 1-3, H-1126 Budapest, Hungary
[4] Semmelweis Univ, Dept Spine Surg, Dept Orthopaed, Ulloi Str 78-b, H-1082 Budapest, Hungary
来源
SPINE JOURNAL | 2024年 / 24卷 / 10期
基金
匈牙利科学研究基金会;
关键词
Biomechanics; Finite element analysis; Lumbopelvic distance reduction; Lumbopelvic fixation; Lumbopelvic reconstruction; Lumbopelvic stabilization; Total sacrectomy; LUMBAR MOTION SEGMENT; SACRAL TUMORS; MECHANICAL-PROPERTIES; ROD INSTRUMENTATION; CALIBRATION METHOD; 4-ROD TECHNIQUE; PELVIC RING; MODEL; SPINE; BONE;
D O I
10.1016/j.spinee.2024.04.024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND CONTEXT: Following total sacrectomy, lumbopelvic reconstruction is essential to restore continuity between the lumbar spine and pelvis. However, to achieve long-term clinical stability, bony fusion between the lumbar spine and the pelvic ring is crucial. Reduction of the lumbopelvic distance can promote successful bony fusion. Although many lumbopelvic reconstruction techniques (LPRTs) have been previously analyzed, the biomechanical effect of lumbopelvic distance reduction (LPDR) has not been investigated yet. PURPOSE: To evaluate and compare the biomechanical characteristics of four different LPRTs while considering the effect of LPDR. STUDY DESIGN/SETTING: A comparative finite element (FE) study. METHODS: The FE models following total sacrectomy were developed to analyze four different LPRTs, with and without LPDR. The closed-loop reconstruction (CLR), the sacral-rod reconstruction (SRR), the four-rod reconstruction (FRR), and the improved compound reconstruction (ICR) techniques were analyzed in flexion, extension, lateral bending, and axial rotation. Lumbopelvic stability was assessed through the shift-down displacement and the relative sagittal rotation of L5, while implant safety was evaluated based on the stress state at the bone-implant interface and within the rods. RESULTS: Regardless of LPDR, both the shift-down displacement and relative sagittal rotation of L5 consistently ranked the LPRTs as ICR25% in CLR, by 61% in SRR, by 15% in FRR, and by 46% in ICR, as well as reduced the relative sagittal rotation values by 21% in CLR, by 73% in SRR, by 11% in FRR, and by 53% in ICR. Considering the stress at the bone- implant interface, without LPDR, the ICR yielded the smallest stress values for flexion, lateral bending, and axial rotation with 131.4 MPa, 68.2 MPa, and 70.3 MPa, respectively, and the second smallest in extension with 36.1 MPa. Due to LPDR, these stress values were reduced by 31% in flexion, by 17% in extension, by 29% in lateral bending, and by 29% in axial rotation. Within the rods, without LPDR, the ICR yielded the smallest stress values for flexion, extension, lateral bending, and axial rotation with 346.5 MPa, 108.0 MPa, 186.2 MPa, and 199.7 MPa, respectively. With LPDR, these stress values were reduced by 16% in flexion, by 9% in extension, by 11% in lateral CONCLUSIONS: LPDR significantly improved both lumbopelvic stability and implant safety in all reconstruction techniques after total sacrectomy. LPDR reduced the shift-down displacement of L5, the relative sagittal rotation of L5, and the stress values at the bone-implant interface. Furthermore, in the ICR and SRR techniques, LPDR decreased the peak stress values within the rods. All four investigated LPRTs demonstrated suitability for lumbopelvic reconstruction, with the ICR following total sacrectomy; therefore, it has the potential to impact the design of custom-made 3D-printed or traditional LPRTs. However, to confirm the findings of the current FE study, longterm clinical trials are recommended.
引用
收藏
页码:1981 / 1992
页数:12
相关论文
共 50 条
  • [21] Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis
    Yuzhu Wang
    Mincong Wang
    Chengguo Li
    Yoshihiro Nakamura
    Liwei Deng
    Go Yamako
    Etsuo Chosa
    Chenglong Pan
    BMC Musculoskeletal Disorders, 23
  • [22] Stress shielding effect after total hip arthroplasty varies between combinations of stem design and stiffness—a comparing biomechanical finite element analysis
    Rene Burchard
    Jan A. Graw
    Christian Soost
    Jan Schmitt
    International Orthopaedics, 2023, 47 : 1981 - 1987
  • [23] Biomechanical evaluation of different reconstructive techniques of proximal tibia in revision total knee arthroplasty: An in-vitro and finite element analysis
    Completo, A.
    Duarte, R.
    Fonseca, F.
    Simoes, J. A.
    Ramos, A.
    Relvas, C.
    CLINICAL BIOMECHANICS, 2013, 28 (03) : 291 - 298
  • [24] Biomechanical effect of intertrochanteric curved varus osteotomy on stress reduction in femoral head osteonecrosis: a finite element analysis
    Wang, Yuzhu
    Yamako, Go
    Okada, Takato
    Arakawa, Hideki
    Nakamura, Yoshihiro
    Chosa, Etsuo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [25] Biomechanical effect of intertrochanteric curved varus osteotomy on stress reduction in femoral head osteonecrosis: a finite element analysis
    Yuzhu Wang
    Go Yamako
    Takato Okada
    Hideki Arakawa
    Yoshihiro Nakamura
    Etsuo Chosa
    Journal of Orthopaedic Surgery and Research, 16
  • [26] Biomechanical evaluation of four different posterior instrumentation techniques for single-level transforaminal lumbar interbody fusion: a finite element analysis
    Guo, Hui-Zhi
    Tang, Yong-Chao
    Guo, Dan-Qing
    Liang, De
    Zhang, Shun-Cong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2020, 12 (10): : 6160 - 6169
  • [27] A comparative analysis of dimensionality reduction surrogate modeling techniques for full human body finite element impact simulations
    Frazer, Lance
    Kote, Vivek
    Hostetler, Zachary
    Davis, Matthew
    Nicolella, Daniel P.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2024, 27 (10) : 1250 - 1263
  • [28] The effect of prosthesis design on vibration of the reconstructed ossicular chain: A comparative finite element analysis of four prostheses
    Kelly, DJ
    Prendergast, PJ
    Blayney, AW
    OTOLOGY & NEUROTOLOGY, 2003, 24 (01) : 11 - 19
  • [29] Stress shielding effect after total hip arthroplasty varies between combinations of stem design and stiffness-a comparing biomechanical finite element analysis
    Burchard, Rene
    Graw, Jan A. A.
    Soost, Christian
    Schmitt, Jan
    INTERNATIONAL ORTHOPAEDICS, 2023, 47 (08) : 1981 - 1987
  • [30] Comparison of the biomechanical properties of grafts in three anterior cruciate ligament reconstruction techniques based on three-dimensional finite element analysis
    Lou, Jiawnag
    Ma, Qi
    Zhao, Xijiu
    Wu, Sha
    Gao, Hong
    Zhang, Wei
    Zhao, Baojing
    Cai, Xu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01):