Comparison of the biomechanical properties of grafts in three anterior cruciate ligament reconstruction techniques based on three-dimensional finite element analysis

被引:1
|
作者
Lou, Jiawnag [1 ,2 ,3 ]
Ma, Qi [2 ,3 ]
Zhao, Xijiu [2 ]
Wu, Sha [2 ,3 ]
Gao, Hong [3 ]
Zhang, Wei [2 ,3 ]
Zhao, Baojing [2 ]
Cai, Xu [2 ,3 ]
机构
[1] Hebei North Univ, 11 South Diamond Rd, Zhangjiakou City 075000, Peoples R China
[2] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Joint Dis Ctr, Sch Clin Med, 168 Litang Rd, Beijing 102218, Peoples R China
[3] Beijing MEDERA Med Grp, Beijing 102200, Peoples R China
来源
关键词
TUNNEL;
D O I
10.1186/s13018-024-04777-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective To evaluate the biomechanical characteristics of grafts from three different anterior cruciate ligament (ACL) reconstructive surgeries and to determine which method is better at restoring knee joint stability.Methods A 31-year-old female volunteer was enrolled in the study. According to the magnetic resonance imaging of her left knee, a three-dimensional model consisting of the distal femur, proximal tibia and fibula, ACL, posterior cruciate ligament, medial collateral ligament and lateral collateral ligament was established. Then, the ACL was removed from the original model to simulate the knee joint after ACL rupture. Based on the knee joint model without the ACL, single-bundle ACL reconstruction, double-bundle ACL reconstruction, and flat-tunnel ACL reconstruction were performed. The cross-sectional diameters of the grafts were equally set as 6 mm in the three groups. The bone tissues had a Young's modulus of 17 GPa and a Poisson's ratio of 0.36. The ligaments and grafts had a Young's modulus of 390 MPa and a Poisson's ratio of 0.4. Six probes were placed in an ACL or a graft to obtain the values of the equivalent stress, maximum principal stress, and maximum shear stress. After pulling the proximal tibia with a forward force of 134 N, the distance that the tibia moved and the stress distribution in the ACL or the graft, reflected by 30 mechanical values, were measured.Results The anterior tibial translation values were similar among the three groups, with the double-bundle ACL reconstruction group performing the best, followed closely by the patellar tendon ACL reconstruction group. In terms of stress distribution, 13 out of 30 mechanical values indicated that the grafts reconstructed by flat bone tunnels had better performance than the grafts in the other groups, while 12 out of 30 showed comparable outcomes, and 5 out of 30 had worse outcomes.Conclusion Compared with traditional single-bundle and double-bundle ACL reconstructions, flat-tunnel ACL reconstruction has advantages in terms of stress dispersion. Additionally, flat-tunnel ACL reconstruction falls between traditional double-bundle and single-bundle ACL reconstructions in terms of restoring knee joint stability and is superior to single-bundle ACL reconstruction.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A Three Dimensional Finite Element of Anterior Cruciate Ligament Model
    Alafiah, A. H.
    Normahira, M.
    Anas, M. N.
    ADVANCED MATERIALS ENGINEERING AND TECHNOLOGY, 2012, 626 : 896 - 901
  • [2] A three-dimensional finite element model of the human anterior cruciate ligament: a computational analysis with experimental validation
    Song, YH
    Debski, RE
    Musahl, V
    Thomas, M
    Woo, SLY
    JOURNAL OF BIOMECHANICS, 2004, 37 (03) : 383 - 390
  • [3] A three-dimensional finite element stress analysis for tunnel placement and buttons in anterior cruciate ligament reconstructions
    Au, AG
    Raso, VJ
    Liggins, AB
    Otto, DD
    Amirfazli, A
    JOURNAL OF BIOMECHANICS, 2005, 38 (04) : 827 - 832
  • [4] Biomechanical analysis of anterior cruciate ligament injury mechanisms: three-dimensional motion reconstruction from video sequences
    Krosshaug, T.
    Slauterbeck, J. R.
    Engebretsen, L.
    Bahr, R.
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2007, 17 (05) : 508 - 519
  • [5] Three-dimensional finite element model of the anterior cruciate ligament: Influence of the initial stress field
    Limbert, G
    Taylor, M
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING - 3, 2001, : 355 - 360
  • [6] A Study on Construction Three-Dimensional Nonlinear Finite Element Model and Stress Distribution Analysis of Anterior Cruciate Ligament
    Xie, Feng
    Yang, Liu
    Guo, Lin
    Wang, Zhi-jun
    Dai, Gang
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (12):
  • [7] Robot-assisted anterior cruciate ligament reconstruction based on three-dimensional images
    Yang, Gang
    Liu, Dingge
    Zhou, Guangjin
    Wang, Qining
    Zhang, Xin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2024, 19 (01)
  • [8] Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament
    Yong In
    Dai-Soon Kwak
    Chan-Woong Moon
    Seung-Ho Han
    Nam-Yong Choi
    Knee Surgery, Sports Traumatology, Arthroscopy, 2012, 20 : 1470 - 1478
  • [9] Biomechanical comparison of three techniques for fixation of tibial avulsion fractures of the anterior cruciate ligament
    In, Yong
    Kwak, Dai-Soon
    Moon, Chan-Woong
    Han, Seung-Ho
    Choi, Nam-Yong
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2012, 20 (08) : 1470 - 1478
  • [10] Biomechanical Comparison of Quadriceps and Patellar Tendon Grafts in Anterior Cruciate Ligament Reconstruction
    Shani, Raj H.
    Umpierez, Erica
    Nasert, Michael
    Hiza, Elise A.
    Xerogeanes, John
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (01): : 71 - 75