Dual-beam X-ray nano-holotomography

被引:0
|
作者
Flenner, Silja [1 ]
Kubec, Adam [2 ]
David, Christian [2 ]
Greving, Imke [1 ]
Hagemann, Johannes [3 ,4 ]
机构
[1] Helmholtz Zentrum Hereon, Max Planck Stra ss 1, Max Planck Str 1, D-21502 Geesthacht, Germany
[2] Paul Scherrer Inst, Forschungs Str 111, CH-5232 Villigen, Switzerland
[3] Deutsch Elektronen Synchrotron DESY, Ctr X ray & Nano Sci CXNS, Notkestr 85, D-22607 Hamburg, Germany
[4] Deutsch Elektronen Synchrotron DESY, Helmholtz Imaging Platform, Notkestr 85, D-22607 Hamburg, Germany
关键词
multibeams; holography; nanotomography; dual beam configuration; holotomography; REAL-TIME;
D O I
10.1107/S1600577524003801
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nanotomography with hard X-rays is a widely used technique for high-resolution imaging, providing insights into the structure and composition of various materials. In recent years, tomographic approaches based on simultaneous illuminations of the same sample region from different angles by multiple beams have been developed at micrometre image resolution. Transferring these techniques to the nanoscale is challenging due to the loss in photon flux by focusing the X-ray beam. We present an approach for multi-beam nanotomography using a dual-beam Fresnel zone plate (dFZP) in a near-field holography setup. The dFZP generates two nano-focused beams that overlap in the sample plane, enabling the simultaneous acquisition of two projections from slightly different angles. This first proof-of-principle implementation of the dual-beam setup allows for the efficient removal of ring artifacts and noise using machinelearning approaches. The results open new possibilities for full-field multi-beam nanotomography and pave the way for future advancements in fast holotomography and artifact-reduction techniques.
引用
收藏
页码:916 / 922
页数:7
相关论文
共 50 条
  • [41] How linearly polarized is the X-ray beam from the X-ray generator?
    Tanaka, S
    Tsunemi, H
    Hayashida, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (9A): : 5770 - 5773
  • [42] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [43] X-ray beam induced current method at the laboratory x-ray source
    Fahrtdinov, R. R.
    Feklisova, O. V.
    Grigoriev, M. V.
    Irzhak, D. V.
    Roshchupkin, D. V.
    Yakimov, E. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (09):
  • [44] New techniques for the measurement of x-ray beam or x-ray optics quality
    Zeitoun, P
    Balcou, P
    Bucourt, S
    Benredjem, D
    Delmotte, F
    Dovillaire, G
    Douillet, D
    Dunn, J
    Faivre, G
    Fajardo, M
    Goldberg, KA
    Idir, M
    Hubert, S
    Hunter, JR
    Jacquemot, S
    Kazamias, S
    le Pape, S
    Levecq, X
    Lewis, CLS
    Marmoret, R
    Mercère, P
    Morlens, AS
    Naulleau, PP
    Rémond, C
    Rocca, JJ
    Sebban, S
    Smith, RF
    Ravet, MF
    Troussel, P
    Valentin, C
    Vanbostal, L
    SOFT X-RAY LASERS AND APPLICATIONS V, 2003, 5197 : 194 - 204
  • [45] SIMPLE DUAL-BEAM PROTEIN METERS
    LARKINS, PL
    MELDRUM, JR
    ANALYTICAL BIOCHEMISTRY, 1975, 63 (01) : 255 - 262
  • [46] DUAL-BEAM HOLOGRAPHIC DEFLECTION MEASUREMENT
    GILBERT, JA
    HERRICK, JW
    EXPERIMENTAL MECHANICS, 1981, 21 (09) : 349 - 354
  • [47] Nano-optical elements fabricated by e-beam and x-ray lithography
    Di Fabrizio, E
    Cojoc, D
    Cabrini, S
    Businaro, L
    Altissimo, M
    Vaccari, L
    Romanato, F
    Malureanu, R
    Kaulich, B
    Wilhein, T
    Susini, J
    NANO-AND MICRO-OPTICS FOR INFORMATION SYSTEMS, 2003, 5225 : 113 - 125
  • [48] Dual-beam phase referencing with VERA
    Honma, M
    Bushimata, T
    Fujii, T
    Hirota, T
    Horiai, K
    Ishitsuka, H
    Iwadate, K
    Jike, T
    Kameya, O
    Kamohara, R
    Kan-ya, Y
    Kawaguchi, N
    Kobayashi, H
    Kuji, S
    Kurayama, T
    Manabe, S
    Miyaji, T
    Nakagawa, A
    Nakashima, K
    Omodaka, T
    Oyama, T
    Rioja, M
    Sakai, S
    Sakakibara, S
    Sato, K
    Sasao, T
    Shibata, KW
    Shimizu, R
    Suda, H
    Tamura, Y
    Future Directions in High Resolution Astronomy: The 10th Anniversary of the VLBA, 2005, 340 : 569 - 571
  • [49] Design of Beam-Steerable Dual-Beam Reflectarray
    Wu, Ping-Hsueh
    Chen, Shih-Yuan
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2017, : 2081 - 2082
  • [50] A MCNP simulation for a new dual-energy dual-beam X-ray inspection method using multi-angle compton scattering to determine the effective atomic number of explosives
    Yim, Che Wook
    Hong, Ser Gi
    RADIATION PHYSICS AND CHEMISTRY, 2022, 195