Dual-beam X-ray nano-holotomography

被引:0
|
作者
Flenner, Silja [1 ]
Kubec, Adam [2 ]
David, Christian [2 ]
Greving, Imke [1 ]
Hagemann, Johannes [3 ,4 ]
机构
[1] Helmholtz Zentrum Hereon, Max Planck Stra ss 1, Max Planck Str 1, D-21502 Geesthacht, Germany
[2] Paul Scherrer Inst, Forschungs Str 111, CH-5232 Villigen, Switzerland
[3] Deutsch Elektronen Synchrotron DESY, Ctr X ray & Nano Sci CXNS, Notkestr 85, D-22607 Hamburg, Germany
[4] Deutsch Elektronen Synchrotron DESY, Helmholtz Imaging Platform, Notkestr 85, D-22607 Hamburg, Germany
关键词
multibeams; holography; nanotomography; dual beam configuration; holotomography; REAL-TIME;
D O I
10.1107/S1600577524003801
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Nanotomography with hard X-rays is a widely used technique for high-resolution imaging, providing insights into the structure and composition of various materials. In recent years, tomographic approaches based on simultaneous illuminations of the same sample region from different angles by multiple beams have been developed at micrometre image resolution. Transferring these techniques to the nanoscale is challenging due to the loss in photon flux by focusing the X-ray beam. We present an approach for multi-beam nanotomography using a dual-beam Fresnel zone plate (dFZP) in a near-field holography setup. The dFZP generates two nano-focused beams that overlap in the sample plane, enabling the simultaneous acquisition of two projections from slightly different angles. This first proof-of-principle implementation of the dual-beam setup allows for the efficient removal of ring artifacts and noise using machinelearning approaches. The results open new possibilities for full-field multi-beam nanotomography and pave the way for future advancements in fast holotomography and artifact-reduction techniques.
引用
收藏
页码:916 / 922
页数:7
相关论文
共 50 条
  • [21] Dual X-ray absorptiometry
    Altman, Albert
    Aaron, Ronald
    AMERICAN JOURNAL OF PHYSICS, 2012, 80 (07) : 621 - 626
  • [22] THE USE OF X-RAY FILMS IN BEAM DIRECTION FOR X-RAY THERAPY
    COPCUTT, WA
    BRITISH JOURNAL OF RADIOLOGY, 1949, 22 (256): : 210 - 214
  • [23] Comparison of Dual X-ray Laser and Dual Energy X-ray Absorptiometry Techniques of Osteodensitometry
    Yumru, A. E.
    Bozkurt, M.
    Aksoy, H. E.
    Coskun, E. Inci
    Ayanoglu, Y. T.
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2009, 37 (02) : 541 - 546
  • [24] DUAL X-RAY ABSORPTIOMETRY - A COMPARISON BETWEEN FAN-BEAM AND PENCIL BEAM SCANS
    BLAKE, GM
    PARKER, JC
    BUXTON, FMA
    FOGELMAN, I
    BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (790): : 902 - 906
  • [25] Laboratory X-ray microscopy with a nano-focus X-ray source
    Nachtrab, Frank
    Ebensperger, Thomas
    Schummer, Bernhard
    Sukowski, Frank
    Hanke, Randolf
    JOURNAL OF INSTRUMENTATION, 2011, 6
  • [26] Fabrication of Nano-grating by Focused Ion Beam/Scanning Electron Microscopy Dual-beam System
    Yao, Baoyin
    Luo, Hu
    Feng, Lishuang
    Zhou, Zhen
    Wang, Rongming
    Chi, Yuanyuan
    MEMS/NEMS NANO TECHNOLOGY, 2011, 483 : 66 - +
  • [27] Body composition measurements with fan beam dual energy x-ray absorptiometry
    Koo, W
    Hammami, M
    PEDIATRIC RESEARCH, 2002, 51 (04) : 314A - 315A
  • [28] Dual X-ray AbsorptiometryClinical Evaluation of a New Cone-Beam System
    G. M. Blake
    K. M. Knapp
    I. Fogelman
    Calcified Tissue International, 2005, 76 : 113 - 120
  • [29] A 3D nanoscale optical memory based on dual-beam writing and dual-beam reading
    Sun, Hongbo
    CHINESE SCIENCE BULLETIN-CHINESE, 2024, 69 (10): : 1248 - 1250
  • [30] Fan beam dual X-ray absorptiometry: an important advance in bone densitometry
    Steiger, P
    BRITISH JOURNAL OF RADIOLOGY, 1998, 71 (849): : 993 - 994