Feasibility of interleaved multislice averaged magnetization inversion-recovery acquisitions of the spinal cord

被引:0
|
作者
Weigel, Matthias [1 ,2 ,3 ,4 ,5 ,6 ]
Celicanin, Zarko [1 ,7 ]
Haas, Tanja [1 ]
Bieri, Oliver [1 ,2 ]
机构
[1] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Petersgraben 4, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[3] Univ Hosp Basel, Fac Med, Dept Biomed Engn, Translat Imaging Neurol ThINK Basel, Basel, Switzerland
[4] Univ Basel, Basel, Switzerland
[5] Univ Hosp Basel, Dept Neurol, Basel, Switzerland
[6] Univ Hosp Basel, Res Ctr Clin Neuroimmunol & Neurosci Basel RC2NB, Basel, Switzerland
[7] Paul Scherrer Inst PSI, Ctr Proton Therapy, Villigen, Switzerland
关键词
AMIRA; averaged magnetization inversion recovery acquisitions; balanced SSFP; interleaved multislice; inversion recovery; spinal cord; GRAY-MATTER ATROPHY; OF-THE-ART; IN-VIVO; ECHO SEQUENCES; SEGMENTATION; MRI;
D O I
10.1002/mrm.30223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo establish an interleaved multislice variant of the averaged magnetization inversion-recovery acquisitions (AMIRA) approach for 2D spinal cord imaging with increased acquisition efficiency compared with the conventional 2D single-slice approach(es), and to determine essential prerequisites for a working interleaved multislice AMIRA approach in practice.MethodsThe general AMIRA concept is based on an inversion recovery-prepared, segmented, and time-limited cine balanced SSFP sequence, generating images of different contrast. For AMIRA imaging of multiple, independent slices in a 2D interleaved fashion, a slice loop within the acquisition loops was programmed. The former non-selective inversions were replaced with slice-selective inversions with user-definable slice thickness.ResultsThe thickness of the slice-selective inversion in 2D interleaved multislice AMIRA should be doubled compared with the manufacturer's standard setting to avoid an increased sensitivity to flow and pulsation effects particularly in the CSF. However, this solution also limits its practical applicability, as slices located at directly adjacent vertebrae cannot be imaged together. Successful interleaved two-slice AMIRA imaging for a "reference" in vivo protocol with 0.50 x 0.50 mm2 in-plane resolution and 8-mm slice thickness is demonstrated, therefore halving its acquisition time per slice from 3 min down to 1.5 min.ConclusionThe investigated 2D interleaved two-slice AMIRA variant facilitates spinal cord imaging that maintains similar contrast and the same resolution as the conventional 2D single-slice AMIRA approach, but does so with a halved acquisition time.
引用
收藏
页码:2588 / 2595
页数:8
相关论文
共 50 条
  • [41] Lesion detection by Double Inversion Recovery (DIR) Brain MRI Sequence in the Upper Spinal Cord in Multiple Sclerosis Patients
    Patel, S.
    Imitola, J.
    Wolansky, L.
    MULTIPLE SCLEROSIS JOURNAL, 2022, 28 (1_SUPPL) : 128 - 128
  • [42] Effective blood signal suppression using double inversion-recovery and slice reordering for multislice fast spin-echo MRI and its application in simultaneous proton density and T2 weighted imaging
    Kuribayashi, H
    Tessier, JJ
    Checkley, DR
    Wang, YX
    Hultin, L
    Waterton, JC
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 881 - 888
  • [43] Spinal Cord Infarction Due to Fibrocartilaginous Embolization: The Role of Diffusion Weighted Imaging and Short-Tau Inversion Recovery Sequences
    Manara, Renzo
    Calderone, Milena
    Severino, Maria Savina
    Citton, Valentina
    Toldo, Irene
    Laverda, Anna Maria
    Sartori, Stefano
    JOURNAL OF CHILD NEUROLOGY, 2010, 25 (08) : 1024 - 1028
  • [44] Longitudinal assessment of recovery after spinal cord injury with behavioral measures and diffusion, quantitative magnetization transfer and functional magnetic resonance imaging
    Wu, Tung-Lin
    Byun, Nellie E.
    Wang, Feng
    Mishra, Arabinda
    Janve, Vaibhav A.
    Chen, Li Min
    Gore, John C.
    NMR IN BIOMEDICINE, 2020, 33 (04)
  • [45] Evaluation of a ketogenic diet for improvement of neurological recovery in individuals with acute spinal cord injury: a pilot, randomized safety and feasibility trial
    Yarar-Fisher C.
    Kulkarni A.
    Li J.
    Farley P.
    Renfro C.
    Aslam H.
    Bosarge P.
    Wilson L.
    Barnes S.
    Spinal Cord Series and Cases, 4 (1)
  • [46] SHORT TAU-INVERSION RECOVERY FAST SPIN-ECHO (FAST STIR) IMAGING OF THE SPINAL-CORD IN MULTIPLE-SCLEROSIS
    THORPE, JW
    MACMANUS, DG
    KENDALL, BE
    TOFTS, PS
    BARKER, GJ
    MCDONALD, WI
    MILLER, DH
    MAGNETIC RESONANCE IMAGING, 1994, 12 (07) : 983 - 989
  • [47] Computer-aided volumetric evaluation method for gray matter in the brain and the spinal cord by T1-weighted inversion recovery MRI
    Tsukamoto, N
    Kumagai, H
    Saitoh, K
    Monma, M
    Ando, Y
    Kitamura, M
    Kawaguchi, O
    CARS 2001: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2001, 1230 : 1109 - 1109
  • [48] Initial feasibility evaluation of the RISES system: An innovative and activity-based closed-loop framework for spinal cord injury rehabilitation and recovery
    Madarshahian, Shirin
    Guerrero, Tatiana
    Aung, Phyo Thuta
    Gustafson, Kristin
    Harrop, James S.
    Johnson, Dana R.
    Khantan, Mehdi
    Lee, Yunsoo
    Matias, Caio
    McCurdy, Michael
    Grampurohit, Namrata
    Mulcahey, Maryjane
    Napoli, Alessandro
    Vaccaro, Alexander
    Serruya, Mijail
    JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2024, 11
  • [49] Feasibility of 3.0 T diffusion-weighted nuclear magnetic resonance imaging in the evaluation of functional recovery of rats with complete spinal cord injury
    Duo Zhang
    Xiao-hui Li
    Xu Zhai
    Xi-jing He
    Neural Regeneration Research, 2015, 10 (03) : 412 - 418
  • [50] Feasibility of Diffusion Tensor Imaging for Assessing Functional Recovery in Rats with Olfactory Ensheathing Cell Transplantation After Contusive Spinal Cord Injury (SCI)
    Gu, Mengchao
    Gao, Zhengchao
    Li, Xiaohui
    Zhao, Feng
    Guo, Lei
    Liu, Jiantao
    He, Xijing
    MEDICAL SCIENCE MONITOR, 2017, 23 : 2961 - 2971