Feasibility of interleaved multislice averaged magnetization inversion-recovery acquisitions of the spinal cord

被引:0
|
作者
Weigel, Matthias [1 ,2 ,3 ,4 ,5 ,6 ]
Celicanin, Zarko [1 ,7 ]
Haas, Tanja [1 ]
Bieri, Oliver [1 ,2 ]
机构
[1] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Petersgraben 4, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[3] Univ Hosp Basel, Fac Med, Dept Biomed Engn, Translat Imaging Neurol ThINK Basel, Basel, Switzerland
[4] Univ Basel, Basel, Switzerland
[5] Univ Hosp Basel, Dept Neurol, Basel, Switzerland
[6] Univ Hosp Basel, Res Ctr Clin Neuroimmunol & Neurosci Basel RC2NB, Basel, Switzerland
[7] Paul Scherrer Inst PSI, Ctr Proton Therapy, Villigen, Switzerland
关键词
AMIRA; averaged magnetization inversion recovery acquisitions; balanced SSFP; interleaved multislice; inversion recovery; spinal cord; GRAY-MATTER ATROPHY; OF-THE-ART; IN-VIVO; ECHO SEQUENCES; SEGMENTATION; MRI;
D O I
10.1002/mrm.30223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo establish an interleaved multislice variant of the averaged magnetization inversion-recovery acquisitions (AMIRA) approach for 2D spinal cord imaging with increased acquisition efficiency compared with the conventional 2D single-slice approach(es), and to determine essential prerequisites for a working interleaved multislice AMIRA approach in practice.MethodsThe general AMIRA concept is based on an inversion recovery-prepared, segmented, and time-limited cine balanced SSFP sequence, generating images of different contrast. For AMIRA imaging of multiple, independent slices in a 2D interleaved fashion, a slice loop within the acquisition loops was programmed. The former non-selective inversions were replaced with slice-selective inversions with user-definable slice thickness.ResultsThe thickness of the slice-selective inversion in 2D interleaved multislice AMIRA should be doubled compared with the manufacturer's standard setting to avoid an increased sensitivity to flow and pulsation effects particularly in the CSF. However, this solution also limits its practical applicability, as slices located at directly adjacent vertebrae cannot be imaged together. Successful interleaved two-slice AMIRA imaging for a "reference" in vivo protocol with 0.50 x 0.50 mm2 in-plane resolution and 8-mm slice thickness is demonstrated, therefore halving its acquisition time per slice from 3 min down to 1.5 min.ConclusionThe investigated 2D interleaved two-slice AMIRA variant facilitates spinal cord imaging that maintains similar contrast and the same resolution as the conventional 2D single-slice AMIRA approach, but does so with a halved acquisition time.
引用
收藏
页码:2588 / 2595
页数:8
相关论文
共 50 条
  • [21] Impact of incidental magnetization transfer effects on inversion-recovery sequences that use a fast spin-echo readout
    Meara, Simon J. P.
    Barker, Gareth J.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (04) : 825 - 829
  • [23] Spatiotemporal trajectories of quantitative magnetization transfer measurements in injured spinal cord using simplified acquisitions
    Wang, Feng
    Wu, Tung-Lin
    Li, Ke
    Chen, Li Min
    Gore, John C.
    NEUROIMAGE-CLINICAL, 2019, 23
  • [24] Noninvasive investigation of exocrine pancreatic function: Feasibility of cine dynamic MRCP with a spatially selective inversion-recovery pulse
    Yasokawa, Kazuya
    Ito, Katsuyoshi
    Tamada, Tsutomu
    Yamamoto, Akira
    Hayashida, Minoru
    Tanimoto, Daigo
    Higaki, Atsushi
    Noda, Yasufumi
    Kido, Ayumu
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (05) : 1266 - 1271
  • [25] Double Inversion Recovery (DIR) sequence of the cervical spinal cord in multiple sclerosis
    Riederer, I.
    Karampinos, D. C.
    Settles, M.
    Preibisch, C.
    Bauer, J. S.
    Kleine, J.
    Muehlau, M.
    Zimmer, C.
    MULTIPLE SCLEROSIS JOURNAL, 2014, 20 : 26 - 27
  • [26] Double inversion recovery to detect cervical spinal cord multiple sclerosis lesions
    Patel, Shivam
    Dimaandal, Ian
    Kuhns, Tyler
    Creed, Marina
    Gershon, Abner
    Wolansky, Ivan
    Imitola, Jaime
    Wolansky, Leo
    JOURNAL OF NEUROIMAGING, 2023, 33 (04) : 521 - 526
  • [27] Enhancing fluid signal in driven-equilibrium short-TI inversion-recovery imaging with short TR times: A feasibility study
    von Deuster, Constantin
    Nanz, Daniel
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (06) : 2571 - 2579
  • [28] Spinal cord microstructure integrating phase-sensitive inversion recovery and diffusional kurtosis imaging
    Panara, V.
    Navarra, R.
    Mattei, P. A.
    Piccirilli, E.
    Cotroneo, A. R.
    Papinutto, N.
    Henry, R. G.
    Uncini, A.
    Caulo, M.
    NEURORADIOLOGY, 2017, 59 (08) : 819 - 827
  • [29] Double Inversion Recovery Sequence of the Cervical Spinal Cord in Multiple Sclerosis and Related Inflammatory Diseases
    Riederer, I.
    Karampinos, D. C.
    Settles, M.
    Preibisch, C.
    Bauer, J. S.
    Kleine, J. F.
    Muehlau, M.
    Zimmer, C.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (01) : 219 - 225
  • [30] Spinal cord microstructure integrating phase-sensitive inversion recovery and diffusional kurtosis imaging
    V. Panara
    R Navarra
    P. A. Mattei
    E. Piccirilli
    A. R. Cotroneo
    N. Papinutto
    R. G. Henry
    A. Uncini
    M. Caulo
    Neuroradiology, 2017, 59 : 819 - 827