Feasibility of interleaved multislice averaged magnetization inversion-recovery acquisitions of the spinal cord

被引:0
|
作者
Weigel, Matthias [1 ,2 ,3 ,4 ,5 ,6 ]
Celicanin, Zarko [1 ,7 ]
Haas, Tanja [1 ]
Bieri, Oliver [1 ,2 ]
机构
[1] Univ Hosp Basel, Dept Radiol, Div Radiol Phys, Petersgraben 4, CH-4031 Basel, Switzerland
[2] Univ Basel, Dept Biomed Engn, Allschwil, Switzerland
[3] Univ Hosp Basel, Fac Med, Dept Biomed Engn, Translat Imaging Neurol ThINK Basel, Basel, Switzerland
[4] Univ Basel, Basel, Switzerland
[5] Univ Hosp Basel, Dept Neurol, Basel, Switzerland
[6] Univ Hosp Basel, Res Ctr Clin Neuroimmunol & Neurosci Basel RC2NB, Basel, Switzerland
[7] Paul Scherrer Inst PSI, Ctr Proton Therapy, Villigen, Switzerland
关键词
AMIRA; averaged magnetization inversion recovery acquisitions; balanced SSFP; interleaved multislice; inversion recovery; spinal cord; GRAY-MATTER ATROPHY; OF-THE-ART; IN-VIVO; ECHO SEQUENCES; SEGMENTATION; MRI;
D O I
10.1002/mrm.30223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo establish an interleaved multislice variant of the averaged magnetization inversion-recovery acquisitions (AMIRA) approach for 2D spinal cord imaging with increased acquisition efficiency compared with the conventional 2D single-slice approach(es), and to determine essential prerequisites for a working interleaved multislice AMIRA approach in practice.MethodsThe general AMIRA concept is based on an inversion recovery-prepared, segmented, and time-limited cine balanced SSFP sequence, generating images of different contrast. For AMIRA imaging of multiple, independent slices in a 2D interleaved fashion, a slice loop within the acquisition loops was programmed. The former non-selective inversions were replaced with slice-selective inversions with user-definable slice thickness.ResultsThe thickness of the slice-selective inversion in 2D interleaved multislice AMIRA should be doubled compared with the manufacturer's standard setting to avoid an increased sensitivity to flow and pulsation effects particularly in the CSF. However, this solution also limits its practical applicability, as slices located at directly adjacent vertebrae cannot be imaged together. Successful interleaved two-slice AMIRA imaging for a "reference" in vivo protocol with 0.50 x 0.50 mm2 in-plane resolution and 8-mm slice thickness is demonstrated, therefore halving its acquisition time per slice from 3 min down to 1.5 min.ConclusionThe investigated 2D interleaved two-slice AMIRA variant facilitates spinal cord imaging that maintains similar contrast and the same resolution as the conventional 2D single-slice AMIRA approach, but does so with a halved acquisition time.
引用
收藏
页码:2588 / 2595
页数:8
相关论文
共 50 条
  • [31] Magnetization Transfer Ratio and Morphometrics of the Spinal Cord Associates with Surgical Recovery in Patients with Degenerative Cervical Myelopathy
    Paliwal, Monica
    Weber, Kenneth A., II
    Hopkins, Benjamin S.
    Cantrell, Donald R.
    Hoggarth, Mark A.
    Elliott, James M.
    Dahdaleh, Nader S.
    Mackey, Sean
    Parrish, Todd D.
    Dhaher, Yasin
    Smith, Zachary A.
    WORLD NEUROSURGERY, 2020, 144 : E939 - E947
  • [32] Feasibility of spinal cord imaging at 7 T using rosette trajectory with magnetization transfer preparation and compressed sensing
    Mahmud, Sultan Z.
    Denney, Thomas S.
    Bashir, Adil
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [33] Feasibility of spinal cord imaging at 7 T using rosette trajectory with magnetization transfer preparation and compressed sensing
    Sultan Z. Mahmud
    Thomas S. Denney
    Adil Bashir
    Scientific Reports, 13
  • [34] Phase Sensitive Inversion Recovery (PSIR) spinal cord imaging as a potential biomarker for Motor Neuron Disease
    Olney, Nicholas
    Bischof, Antje
    Rosen, Howard
    Caverzasi, Eduardo
    Stern, William
    Lomen-Hoerth, Catherine
    Miller, Bruce
    Henry, Roland
    Papinutto, Nico
    NEUROLOGY, 2018, 90
  • [35] Relationships between spinal cord blood flow measured with flow-sensitive alternating inversion recovery (FAIR) and neurobehavioral outcomes in rat spinal cord injury
    Lee, Seongtaek
    Wilkins, Natasha
    Schmit, Brian D.
    Kurpad, Shekar N.
    Budde, Matthew D.
    MAGNETIC RESONANCE IMAGING, 2021, 78 : 42 - 51
  • [36] Human gray matter: Feasibility of single-slab 3D double inversion-recovery high-spatial-resolution MR imaging
    Pouwels, Petra J. W.
    Kuijer, Joost P. A.
    Mugler, John P., III
    Guttmann, Charles R. G.
    Barkhof, Frederik
    RADIOLOGY, 2006, 241 (03) : 873 - 879
  • [37] Feasibility study of highly accelerated phase-sensitive inversion recovery myocardial viability imaging using simultaneous multislice and parallel imaging techniques
    Zhang, Zhehao
    Sun, Wenbo
    Lan, Lan
    Zheng, Yuan
    Xu, Jian
    Du, Yiping
    Xu, Haibo
    Chen, Qun
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 50 (06) : 1964 - 1972
  • [38] Measurement of spinal cord atrophy using phase sensitive inversion recovery (PSIR) imaging in motor neuron disease
    Olney, Nicholas T.
    Bischof, Antje
    Rosen, Howard
    Caverzasi, Eduardo
    Stern, William A.
    Lomen-Hoerth, Catherine
    Miller, Bruce L.
    Henry, Roland G.
    Papinutto, Nico
    PLOS ONE, 2018, 13 (11):
  • [39] Inversion recovery versus T2-weighted sagittal MR imaging in cervical spinal cord injury
    Killeen K.L.
    Shanmuganathan K.
    Lefkowitz D.
    Mirvis S.E.
    Owens E.
    Emergency Radiology, 2001, 8 (1) : 15 - 19
  • [40] MAGNETIC-RESONANCE-IMAGING OF SPINAL-CORD IN MULTIPLE-SCLEROSIS BY FLUID-ATTENUATED INVERSION RECOVERY
    THOMAS, DJ
    PENNOCK, JM
    HAJNAL, JV
    YOUNG, IR
    BYDDER, GM
    STEINER, RE
    LANCET, 1993, 341 (8845): : 593 - 594