Performance Enhancement Analysis of Environmentally Friendly Refrigerants

被引:0
|
作者
Hsieh, Chun-Yu [1 ]
Yeh, Rong-Hua [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Marine Engn, Kaohsiung 805301, Taiwan
关键词
refrigerant; coefficient of performance; evaporation temperature; condensation temperature; global warming potential; ozone depletion potential; LOW-GWP REFRIGERANTS; ENERGY; R134A; SELECTION; SINGLE; R513A;
D O I
10.3390/pr12050904
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, -20, -40, and -60 degrees C and condensation temperatures of 30, 40, and 50 degrees C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 degrees C and -20 degrees C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = -40 degrees C and -60 degrees C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = -60 degrees C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = -40 degrees C and -60 degrees C. However, the growth rate of R717 ranks last for Teva = -60 degrees C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.
引用
收藏
页数:19
相关论文
共 50 条
  • [21] Operation performance of an ultralow-temperature cascade refrigeration freezer with environmentally friendly refrigerants R290-R170
    Tan, Haihui
    Xu, Lingfei
    Yang, Linlin
    Bai, Minkai
    Liu, Zhan
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (11) : 29790 - 29806
  • [22] Development of Correlations Based on CFD Study for Microchannel Condensation Flow of Environmentally Friendly Hydrocarbon Refrigerants
    Basaran, Anil
    Benim, Ali Cemal
    [J]. ENERGIES, 2024, 17 (07)
  • [23] Thermodynamic Assessment of Using Water as a Refrigerant in Cascade Refrigeration Systems With Other Environmentally Friendly Refrigerants
    Alkhulaifi, Yousif M.
    Mokheimer, Esmail M. A.
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2022, 144 (02):
  • [24] Fort William town centre enhancement: Environmentally friendly engineering?
    Brown, GM
    Hutchinson, JC
    Innes, NW
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-MUNICIPAL ENGINEER, 1996, 115 (01) : 1 - 9
  • [25] Preparation and performance analysis of enteromorpha-based environmentally friendly dust suppressant
    Zhao, Zhendong
    Zhao, Yanyun
    Hu, Xiangming
    Cheng, Weimin
    Hou, Jiaoyun
    Song, Chunyu
    [J]. POWDER TECHNOLOGY, 2021, 393 : 323 - 332
  • [26] High-Temperature Two-Stage Subcritical Heat Pump Running on Environmentally Friendly Refrigerants
    Obstawski, Pawel
    Tomczuk, Krzysztof
    [J]. ADVANCES IN SCIENCE AND TECHNOLOGY-RESEARCH JOURNAL, 2024, 18 (03) : 369 - 381
  • [27] CLIMATE-FRIENDLY REFRIGERANTS
    Gibb, Steven
    [J]. CHEMICAL & ENGINEERING NEWS, 2015, 93 (10) : 6 - 6
  • [28] Theoretical performance studies on environment friendly refrigerants used in refrigeration units
    Nagarjuna Kumma
    Gokul Sai Seethala
    Yatna Bhagat
    Sai Sarath
    Satya Sai Harish Kruthiventi
    [J]. Environmental Science and Pollution Research, 2023, 30 : 63065 - 63083
  • [29] PERFORMANCE ANALYSIS OF SOLAR COMBINED EJECTOR-VAPOR COMPRESSION CYCLE USING ENVIRONMENTAL FRIENDLY REFRIGERANTS
    Kasaeian, A. B.
    Daviran, S.
    [J]. IIUM ENGINEERING JOURNAL, 2013, 14 (01): : 93 - 103
  • [30] Theoretical performance studies on environment friendly refrigerants used in refrigeration units
    Kumma, Nagarjuna
    Seethala, Gokul Sai
    Bhagat, Yatna
    Sarath, Sai
    Kruthiventi, Satya Sai Harish
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2023, 30 (22) : 63065 - 63083