Performance Enhancement Analysis of Environmentally Friendly Refrigerants

被引:0
|
作者
Hsieh, Chun-Yu [1 ]
Yeh, Rong-Hua [1 ]
机构
[1] Natl Kaohsiung Univ Sci & Technol, Dept Marine Engn, Kaohsiung 805301, Taiwan
关键词
refrigerant; coefficient of performance; evaporation temperature; condensation temperature; global warming potential; ozone depletion potential; LOW-GWP REFRIGERANTS; ENERGY; R134A; SELECTION; SINGLE; R513A;
D O I
10.3390/pr12050904
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Due to the impact of global warming and climate change, more and more people are starting to have a clearer understanding and vigilance about greenhouse gases. To prevent further deterioration of the global environment, this study examines the coefficients of performance of 21 currently available refrigerants with very low global-warming potential and zero ozone-depleting potential under evaporation temperatures of 10, -20, -40, and -60 degrees C and condensation temperatures of 30, 40, and 50 degrees C, respectively. It is found that the use of pure refrigerant in a two-stage refrigeration system to replace the single-stage refrigeration system, in addition to mixing it into an appropriate mixture, can effectively improve the performance coefficient of the refrigeration system. For single-stage vapor compression refrigeration systems, R1234ze(Z), R601, and R1233zd(E) have the best refrigeration performances among the environmentally friendly refrigerants studied, while R441A performs the worst for Teva = 10 degrees C and -20 degrees C. Moreover, RE170 has the highest COP of the refrigeration system for Teva = -40 degrees C and -60 degrees C. However, R1234yf performs worse in COP when the evaporation temperature is lower, and it ranks last for Teva = -60 degrees C. When a double-stage vapor compression refrigeration system is employed instead, the percentage increase in the COP of the system using R1234yf becomes the largest for Teva = -40 degrees C and -60 degrees C. However, the growth rate of R717 ranks last for Teva = -60 degrees C. For an R717/R1234yf mixture at an optimum mass fraction of 0.25, the COP of the refrigeration system can be increased up to 25.8% despite an increase of 15.2% in operating pressure compared to R1234yf. The discharge temperature may rise; however, there will be no overheating problem for the compressor.
引用
收藏
页数:19
相关论文
共 50 条
  • [31] Analysis of a vapour ejector refrigeration system with environment friendly refrigerants
    Selvaraju, A
    Mani, A
    [J]. INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2004, 43 (09) : 915 - 921
  • [32] Biodegradation performance of environmentally-friendly insulating oil
    Yang, Jun
    He, Yan
    Cai, Shengwei
    Chen, Cheng
    Wen, Gang
    Wang, Feipeng
    Fan, Fan
    Wan, Chunxiang
    Wu, Liya
    Liu, Ruitong
    [J]. INTERNATIONAL CONFERENCE ON ENERGY ENGINEERING AND ENVIRONMENTAL PROTECTION (EEEP2017), 2018, 121
  • [33] Environmentally friendly
    不详
    [J]. COMMUNICATIONS NEWS, 1997, 34 (11): : 38 - 39
  • [34] Investigation on hydrodynamic performance of an environmentally friendly pile breakwater
    Mojtahedi, Alireza
    Beiragh, Mehrdad Shokatian
    Farajpour, Ismail
    Mohammadian, Majid
    [J]. OCEAN ENGINEERING, 2020, 217
  • [35] Tribological Performance of Environmentally Friendly Ionic Liquid Lubricants
    Reeves, Carlton J.
    Garvey, Sarah
    Menezes, Pradeep L.
    Dietz, Mark
    Jen, Tien-Chien
    Lovell, Michael R.
    [J]. PROCEEDINGS OF THE ASME/STLE INTERNATIONAL JOINT TRIBOLOGY CONFERENCE, IJTC 2012, 2013, : 355 - 357
  • [36] ENVIRONMENTALLY BENIGN REFRIGERANTS PERFORM WELL
    不详
    [J]. EPRI JOURNAL, 1995, 20 (01): : 4 - 4
  • [37] Numerical evaluation of a solar-assisted jet-ejector refrigeration system: Screening of environmentally friendly refrigerants
    Galindo, Jose
    Dolz, Vicente
    Miguel Garcia-Cuevas, Luis
    Ponce-Mora, Alberto
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2020, 210
  • [38] Utilization of ultra-low temperature heat by a novel cascade refrigeration system with environmentally-friendly refrigerants
    He, Yijian
    Jiang, Yunyun
    Fan, Yuchen
    Chen, Guangming
    Tang, Liming
    [J]. RENEWABLE ENERGY, 2020, 157 : 204 - 213
  • [39] Energy performance of a compression refrigeration cycle using environment-friendly refrigerants
    Karthick, L.
    Mallampati, Mahesh
    Murugan, V. Senthil
    Leon, Stephen Leon Joseph
    Ahamed, M. Ijas
    Loganathan, Ganesh Babu
    [J]. MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 1519 - 1525
  • [40] Environmentally friendly high performance timber-concrete panel
    Martins, Carlos
    Dias, Alfredo M. P. G.
    Costa, R.
    Santos, Pedro
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 102 : 1060 - 1069