A study of the reliability and construct validity of the 1-minute sit-to-stand test for individuals with systemic sclerosis

被引:0
|
作者
Laursen, Jakob [1 ]
Christensen, Amalie [1 ]
Egsgaard, Simon [1 ]
Sondergaard, Klaus [2 ]
Mechlenburg, Inger [3 ,4 ]
Brincks, John [1 ]
机构
[1] VIA Univ Coll, Res Ctr Prevent & Hlth Promot, Hedeager 2, DK-8200 Aarhus, Denmark
[2] Aarhus Univ Hosp, Dept Rheumatol, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Orthopaed Surg, Aarhus, Denmark
[4] Aarhus Univ, Dept Clin Med, Aarhus, Denmark
关键词
Systemic sclerosis; physical functional performance; reliability; construct validity;
D O I
10.1080/09593985.2024.2373392
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective This study seeks to assess the reliability and construct validity of the 1-minute sit-to-stand test as an efficient tool for evaluating the functional capacity of individuals with systemic sclerosis, considering its time and space effectiveness. Methods This cross-sectional study recruited forty-nine individuals with systemic sclerosis from a university hospital in Denmark. The 1-minute sit-to-stand test was conducted twice on the same day, with an interval of approximately 10 to 15 minutes between administrations, followed by a single administration of the 6-minute walk test. Reliability and validity were estimated using Bland-Altman statistics, intraclass correlation coefficient (ICC2,1), paired t-test, and Spearman's rank correlation coefficient (rho). Results The 1-minute sit-to-stand test exhibited excellent test-retest reliability with an ICC2,1 (CI) of 0.97 (0.95-0.99). The minimal metrically detectable change between separate measures on a subject for the difference in the measures to be considered real at the 95% confidence level was 2.9 repetitions and 11%, respectively. A learning effect of one repetition was observed between repeated measures. High construct validity was observed between the 1-minute sit-to-stand and 6-minute walk test (rho = 0.78, p < .001). Conclusions This study demonstrates the 1-minute sit-to-stand test as highly reliable, with an 11% change indicating a true outcome change. It also demonstrates robust construct validity compared to the 6-minute walk test. The 1-minute sit-to-stand test appears feasible for assessing functional capacity in well-functioning individuals with systemic sclerosis, but prior familiarization with the task is recommended, as a small learning effect was observed with one repetition.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] The effects of standardised versus individualised seat height on 1-minute sit-to-stand test performance in healthy individuals: a randomised crossover trial
    Kuhn, Manuel
    Vollenweider, Sibylle
    Clarenbach, Christian F. F.
    Kohlbrenner, Dario
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2023, 123 (07) : 1543 - 1551
  • [22] The effects of standardised versus individualised seat height on 1-minute sit-to-stand test performance in healthy individuals: a randomised crossover trial
    Manuel Kuhn
    Sibylle Vollenweider
    Christian F. Clarenbach
    Dario Kohlbrenner
    [J]. European Journal of Applied Physiology, 2023, 123 : 1543 - 1551
  • [23] Relationship between 1-minute and 5-repetition sit-to-stand tests in COPD
    Machado, Ana
    Oliveira, Ana
    Melro, Helder
    Miranda, Sara
    Andrade, Lilia
    Marques, Alda Sofia Pires de Dias
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2017, 50
  • [24] In adults with advanced lung disease, the 1-minute sit-to-stand test underestimates exertional desaturation compared with the 6-minute walk test: an observational study
    Watson, Kathryn
    Winship, Peta
    Cavalheri, Vinicius
    Vicary, Caitlin
    Stray, Stephanie
    Bear, Natasha
    Hill, Kylie
    [J]. JOURNAL OF PHYSIOTHERAPY, 2023, 69 (02) : 108 - 113
  • [25] The 1-Minute Sit-to-Stand Test in Adults With Cystic Fibrosis: Correlations With Cardiopulmonary Exercise Test, 6-Minute Walk Test, and Quadriceps Strength
    Gruet, Mathieu
    Peyre-Tartaruga, Leonardo Alexandre
    Mely, Laurent
    Vallier, Jean-Marc
    [J]. RESPIRATORY CARE, 2016, 61 (12) : 1620 - 1628
  • [26] Detection of impaired gas exchange using the 1-minute sit-to-stand test in patients with interstitial lung disease
    Oishi, Keiji
    Asami-Noyama, Maki
    Yamamoto, Tasuku
    Matsumori, Kosuke
    Yonezawa, Kosei
    Watanabe, Michiya
    Hisamoto, Yukari
    Fukatsu, Ayumi
    Matsuda, Kazuki
    Hamada, Kazuki
    Suetake, Ryo
    Ohata, Syuichiro
    Murata, Yoriyuki
    Yamaji, Yoshikazu
    Sakamoto, Kenji
    Ito, Kosuke
    Osoreda, Hisayuki
    Edakuni, Nobutaka
    Kakugawa, Tomoyuki
    Hirano, Tsunahiko
    Matsunaga, Kazuto
    [J]. RESPIRATORY INVESTIGATION, 2023, 61 (02) : 186 - 189
  • [27] Sit-to-stand biomechanics of individuals with multiple sclerosis
    Bowser, Bradley
    O'Rourke, Sean
    Brown, Cathleen N.
    White, Lesley
    Simpson, Kathy J.
    [J]. CLINICAL BIOMECHANICS, 2015, 30 (08) : 788 - 794
  • [28] The validity of the 5 and 10 sit-to-stand test
    Carling, A.
    Nilsagard, Y.
    [J]. MULTIPLE SCLEROSIS JOURNAL, 2015, 21 (04) : 532 - 532
  • [29] The 1-minute sit-to-stand test to detect exercise-induced oxygen desaturation in patients with interstitial lung disease
    Briand, Justine
    Behal, Helene
    Chenivesse, Cecile
    Wemeau-Stervinou, Lidwine
    Wallaert, Benoit
    [J]. THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE, 2018, 12
  • [30] Is the 1-Minute Sit-to-Stand Test a Good Tool to Evaluate Exertional Oxygen Desaturation in Chronic Obstructive Pulmonary Disease?
    Fernandes, Ana L.
    Neves, Ines
    Luis, Graciete
    Camilo, Zita
    Cabrita, Bruno
    Dias, Sara
    Ferreira, Jorge
    Simao, Paula
    [J]. DIAGNOSTICS, 2021, 11 (02)