摘要
Objective This study seeks to assess the reliability and construct validity of the 1-minute sit-to-stand test as an efficient tool for evaluating the functional capacity of individuals with systemic sclerosis, considering its time and space effectiveness. Methods This cross-sectional study recruited forty-nine individuals with systemic sclerosis from a university hospital in Denmark. The 1-minute sit-to-stand test was conducted twice on the same day, with an interval of approximately 10 to 15 minutes between administrations, followed by a single administration of the 6-minute walk test. Reliability and validity were estimated using Bland-Altman statistics, intraclass correlation coefficient (ICC2,1), paired t-test, and Spearman's rank correlation coefficient (rho). Results The 1-minute sit-to-stand test exhibited excellent test-retest reliability with an ICC2,1 (CI) of 0.97 (0.95-0.99). The minimal metrically detectable change between separate measures on a subject for the difference in the measures to be considered real at the 95% confidence level was 2.9 repetitions and 11%, respectively. A learning effect of one repetition was observed between repeated measures. High construct validity was observed between the 1-minute sit-to-stand and 6-minute walk test (rho = 0.78, p < .001). Conclusions This study demonstrates the 1-minute sit-to-stand test as highly reliable, with an 11% change indicating a true outcome change. It also demonstrates robust construct validity compared to the 6-minute walk test. The 1-minute sit-to-stand test appears feasible for assessing functional capacity in well-functioning individuals with systemic sclerosis, but prior familiarization with the task is recommended, as a small learning effect was observed with one repetition.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Prognostic value of the 1-minute sit-to-stand test on postoperative complications in people with lung cancer elected for lung surgery
    Quadflieg, K.
    Higgins, R.
    Criel, M.
    Daenen, M.
    Ruttens, D.
    Thomeer, M.
    Maiorana, A.
    Burtin, C.
    Cavalheri, V.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [32] Reliability and validity of sit-to-stand test protocols in patients with coronary artery disease
    Wang, Zheng
    Yan, Jianhua
    Meng, Shu
    Li, Jiajia
    Yu, Yi
    Zhang, Tingting
    Tsang, Raymond C. C.
    El-Ansary, Doa
    Han, Jia
    Jones, Alice Y. M.
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [33] Reliability, validity & responsiveness of the five-repetition sit-to-stand test in COPD
    Jones, Sarah E.
    Kon, Samantha S. C.
    Canavan, Jane L.
    Patel, Mehul S.
    Clark, Amy L.
    Nolan, Claire M.
    Polkey, Michael I.
    Man, William D. -C.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2013, 42
  • [34] Modified 30-Second Sit-to-Stand Test: Reliability and Validity in Older Adults Unable to Complete Traditional Sit-to-Stand Testing
    McAllister, Linda S.
    Palombaro, Kerstin M.
    [J]. JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2020, 43 (03) : 153 - 158
  • [35] Is the 1-minute sit-to-stand test a good tool for the evaluation of the impact of pulmonary rehabilitation? Determination of the minimal important difference in COPD
    Vaidya, Trija
    de Bisschop, Claire
    Beaumont, Marc
    Ouksel, Hakima
    Jean, Veronique
    Dessables, Francois
    Chambellan, Arnaud
    [J]. INTERNATIONAL JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 11 : 2609 - 2616
  • [36] The minimal important difference for the 1-minute sit-to-stand test following pulmonary rehabilitation in patients with COPD - a prospective observational trial
    Schneeberger, Tessa
    Gloeckl, Rainer
    Jarosch, Inga
    Drechsel, Franziska
    Koczulla, Andreas Rembert
    Kenn, Klaus
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2018, 52
  • [37] Validity and reliability of the one-minute sit-to-stand test for the measurement of cardio-respiratory responses in children with cystic fibrosis
    Combret, Yann
    Prieur, Guillaume
    Boujibar, Fairuz
    Gravier, Francis-Edouard
    Smondack, Pauline
    Roux, Pascal Le
    Bonnevie, Tristan
    Medrinal, Clement
    Reychler, Gregory
    [J]. PULMONOLOGY, 2022, 28 (02): : 137 - 139
  • [38] Validity and variability of the 5-repetition sit-to-stand test in patients with multiple sclerosis
    Moller, Andreas Buch
    Bibby, Bo Martin
    Skjerbaek, Anders Guldhammer
    Jensen, Ellen
    Sorensen, Henrik
    Stenager, Egon
    Dalgas, Ulrik
    [J]. DISABILITY AND REHABILITATION, 2012, 34 (26) : 2251 - 2258
  • [39] Reliability and validity of the five-repetition sit-to-stand test for children with cerebral palsy
    Wang, Tze-Hsuan
    Liao, Hua-Fang
    Peng, Yi-Chun
    [J]. CLINICAL REHABILITATION, 2012, 26 (07) : 664 - 671
  • [40] Reliability of the sit-to-stand test over dispersed test sessions
    Schaubert, K
    Bohannon, RW
    [J]. ISOKINETICS AND EXERCISE SCIENCE, 2005, 13 (02) : 119 - 122