The 1-minute sit-to-stand test to detect exercise-induced oxygen desaturation in patients with interstitial lung disease

被引:62
|
作者
Briand, Justine [1 ,2 ]
Behal, Helene [2 ,3 ]
Chenivesse, Cecile [1 ]
Wemeau-Stervinou, Lidwine [1 ]
Wallaert, Benoit [1 ]
机构
[1] CHU Lille, Serv Pneumol & Immuno Allergol, Ctr Competence Malad Pulmonaires Rares, F-59000 Lille, France
[2] Univ Lille, F-59000 Lille, France
[3] CHU Lille, EA 2694, Sante Publ Epidemiol & Qualite Soins, Unite Biostat, F-59000 Lille, France
关键词
1-min sit-to-stand test; 6-min walk test; exercise; functional tests; interstitial lung disease; IDIOPATHIC PULMONARY-FIBROSIS; 6-MINUTE WALK TEST; FUNCTIONAL TESTS; GAS-EXCHANGE; PREDICTOR; MORTALITY; DISTANCE; DYSPNEA;
D O I
10.1177/1753466618793028
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background: Although the 6-min walk test (6MWT) is the gold standard for assessing exercise-induced impairment of gas exchange, it cannot easily be performed in a clinical office environment. The aim of this study was to compare the 1-min sit-to-stand test (1STST) with the 6MWT for the ability to assess exercise-induced oxygen desaturation in patients with interstitial lung diseases (ILDs). Methods: A total of 107 patients were enrolled and classified into three groups: sarcoidosis, fibrotic idiopathic interstitial pneumonia (f-IIP), and other forms of ILD. The 6MWT and 1STST were performed on the same day, and pulmonary function tests, pulse oxygen saturation (SpO(2)), and dyspnea and fatigue (modified Borg scale) were assessed. SpO(2) desaturation was evaluated by intraclass correlation coefficient (ICC), Bland-Altman analysis, and kappa () coefficient in the whole population and the patient subgroups. Results: The SpO(2) nadir during the 1STST and 6MWT showed good consistency [mean standard deviation: 92.5% +/- 5% and 90% +/- 7%, respectively; ICC 0.77, 95% confidence interval (CI) 0.71-0.83] and correlated strongly (r = 0.9, p < 0.0001). The frequency of patients with oxygen desaturation 4% was also consistent for the two exercise tests ( = 0.68, 95% CI 0.54-0.82). The number of repetitions in the 1STST correlated with the 6MWT distance (r = 0.5, p < 0.0001), but the dyspnea scores were higher during the 1STST than the 6MWT (p < 0.0001). These findings did not differ for the three patient subgroups. Conclusion: The 1STST can measure exercise-induced desaturation in ILD patients and could be used as an alternative test to the 6MWT in office practice.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] The 1-minute sit-to-stand test to detect desaturation during 6-minute walk test in interstitial lung disease
    Oishi, Keiji
    Matsunaga, Kazuto
    Asami-Noyama, Maki
    Yamamoto, Tasuku
    Hisamoto, Yukari
    Fujii, Tetsuya
    Harada, Misa
    Suizu, Junki
    Murakawa, Keita
    Chikumoto, Ayumi
    Matsuda, Kazuki
    Kanesada, Haruka
    Kikuchi, Yujiro
    Hamada, Kazuki
    Uehara, Sho
    Suetake, Ryo
    Ohata, Syuichiro
    Murata, Yoriyuki
    Yamaji, Yoshikazu
    Sakamoto, Kenji
    Ito, Kosuke
    Osoreda, Hisayuki
    Edakuni, Nobutaka
    Kakugawa, Tomoyuki
    Hirano, Tsunahiko
    Yano, Masafumi
    [J]. NPJ PRIMARY CARE RESPIRATORY MEDICINE, 2022, 32 (01)
  • [2] The 1-minute sit-to-stand test to detect desaturation during 6-minute walk test in interstitial lung disease
    Keiji Oishi
    Kazuto Matsunaga
    Maki Asami-Noyama
    Tasuku Yamamoto
    Yukari Hisamoto
    Tetsuya Fujii
    Misa Harada
    Junki Suizu
    Keita Murakawa
    Ayumi Chikumoto
    Kazuki Matsuda
    Haruka Kanesada
    Yujiro Kikuchi
    Kazuki Hamada
    Sho Uehara
    Ryo Suetake
    Syuichiro Ohata
    Yoriyuki Murata
    Yoshikazu Yamaji
    Kenji Sakamoto
    Kosuke Ito
    Hisayuki Osoreda
    Nobutaka Edakuni
    Tomoyuki Kakugawa
    Tsunahiko Hirano
    Masafumi Yano
    [J]. npj Primary Care Respiratory Medicine, 32
  • [3] The utility of 1-minute sit-to-stand test to detect exercise-induced oxygen desaturation in outpatient assessment of post COVID-19 patients.
    Ibrahim, M. A.
    Kamarudin, M. N.
    Chai, C. S.
    Rani, M. F. Abdul
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2022, 60
  • [4] The 1-minute sit-to-stand test to help detect exertional desaturation during the 6-minute walk test in interstitial lung disease patients with normal resting blood oxygen levels
    Oishi, Keiji
    Matsunaga, Kazuto
    Asami-Noyama, Maki
    Yamamoto, Tasuku
    Hisamoto, Yukari
    Fujii, Tetsuya
    Harada, Misa
    Suizu, Junki
    Chikumoto, Ayumi
    Kikuchi, Yujiro
    Hamada, Kazuki
    Uehara, Sho
    Ohhata, Suichiro
    Murata, Yoriyuki
    Yamaji, Yoshikazu
    Sakamoto, Kenji
    Edakuni, Nobutaka
    Kakugawa, Tomoyuki
    Hirano, Tsunahiko
    Yano, Masafumi
    [J]. RESPIROLOGY, 2021, 26 : 4 - 4
  • [5] The 1-minute sit-to-stand test to evaluate quadriceps muscle strength in patients with interstitial lung disease
    Wallaert, B.
    Briand, J.
    Behal, H.
    Perez, T.
    Wemeau, L.
    Chenivesse, C.
    [J]. RESPIRATORY MEDICINE AND RESEARCH, 2020, 78
  • [6] The 1-min sit-to-stand test as a screening tool to assess exercise-induced oxygen desaturation in normoxemic people with interstitial lung disease
    Visser, Simone
    Lawler, Chloe
    Fermoyle, Caitlin C.
    Spencer, Lissa M.
    McAnulty, Amanda J.
    Alison, Jennifer A.
    Webster, Susanne
    Troy, Lauren
    Jo, Helen
    Hayen, Andrew
    Corte, Tamera J.
    [J]. RESPIRATORY MEDICINE, 2024, 232
  • [7] Detection of impaired gas exchange using the 1-minute sit-to-stand test in patients with interstitial lung disease
    Oishi, Keiji
    Asami-Noyama, Maki
    Yamamoto, Tasuku
    Matsumori, Kosuke
    Yonezawa, Kosei
    Watanabe, Michiya
    Hisamoto, Yukari
    Fukatsu, Ayumi
    Matsuda, Kazuki
    Hamada, Kazuki
    Suetake, Ryo
    Ohata, Syuichiro
    Murata, Yoriyuki
    Yamaji, Yoshikazu
    Sakamoto, Kenji
    Ito, Kosuke
    Osoreda, Hisayuki
    Edakuni, Nobutaka
    Kakugawa, Tomoyuki
    Hirano, Tsunahiko
    Matsunaga, Kazuto
    [J]. RESPIRATORY INVESTIGATION, 2023, 61 (02) : 186 - 189
  • [8] Is the 1-Minute Sit-to-Stand Test a Good Tool to Evaluate Exertional Oxygen Desaturation in Chronic Obstructive Pulmonary Disease?
    Fernandes, Ana L.
    Neves, Ines
    Luis, Graciete
    Camilo, Zita
    Cabrita, Bruno
    Dias, Sara
    Ferreira, Jorge
    Simao, Paula
    [J]. DIAGNOSTICS, 2021, 11 (02)
  • [9] A multicentre validation of the 1-minute sit-to-stand test in COPD patients
    Crook, Sarah
    Schultz, Konrad
    Lehbert, Nicola
    Busching, Gilbert
    Jelusic, Danijel
    Keusch, Stephan
    Wittmann, Michael
    Schuler, Michael
    Radtke, Thomas
    Turk, Alexander
    Frey, Martin
    Puhan, Milo
    Frei, Anja
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [10] A Simple Sit-to-Stand Test to Detect Exercise-Induced Oxygen Desaturation in Patients Being Discharged from Hospital with COVID-19
    Houchen-Wolloff, L.
    Daynes, E.
    Gerlis, C.
    Chaplin, E.
    Gardiner, N.
    Singh, S. J.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)