Guide vane angle and reactor coolant pump performance during idling

被引:1
|
作者
Ye, Daoxing [1 ,2 ]
Zhai, Fengli [1 ]
Luo, Yimin [1 ]
Wu, Jinchen [1 ]
Chen, Junlin [1 ]
Lai, Xide [1 ]
Tian, Wen [1 ]
机构
[1] Xihua Univ, Sch Energy & Power Engn, Chengdu 610039, Sichuan, Peoples R China
[2] Xihua Univ, Key Lab Fluid & Power Machinery, Minist Educ, Chengdu 610039, Sichuan, Peoples R China
关键词
Reactor coolant pump; Idling characteristics; External characteristics; Radial force; Blade load;
D O I
10.1016/j.anucene.2024.110720
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to study the influence of different guide vane angle variation on performance characteristics of reactor coolant pump (RCP) during idling process, the external characteristics of RCP model with five different guide vane angles at idling process state were analyzed. Radial force characteristics and blade load characteristics of RCP were analyzed. The results show that the head and torque changes of pump with different guide vane angles in different idle period are consistent. The head of DY1model (Guide vane angle increases sharply first and then decreases gently, which convexity is large) is the highest and torque is small. The head drop rate of DY5 model (Guide vane decreases first and then increases, and the concavity is large) is the highest and torque is the largest. With the idling, the radial force of impeller and guide vane decreases gradually. The radial force of DY5 model impeller is small and the fluctuation range is weak. The radial force of DY4 model (Guide vane shows concavity change with gentle increase) impeller before idling is the largest. In the nonlinear transition of idle period, the total radial force of DY4 model is 235 N when idling for 32 s, which is nearly 30 times lower than that before idling, and the radial force decreases the most. In different idling periods, the radial force amplitude of guide vane of DY5 model is the largest, and the radial force decrease amplitude of guide vane of DY4 model is the largest in the whole idling period. The impeller blade load of DY4 and DY5 model pumps with concavity guide vane angle change law is significantly higher than that of other model pumps after the relative position of streamline is 0.6. When the relative position of the guide vane along the streamline direction is less than 0.5, the load fluctuation of the guide vane of each model pump is large. When the relative position is greater than 0.5, the blade load fluctuation is relatively small.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Complete and homologous pump characteristics for a reactor coolant pump
    Park, Jin Seok
    Kim, Jong Wook
    Lee, Jae Seon
    NUCLEAR ENGINEERING AND DESIGN, 2020, 357
  • [42] FLOW TRANSIENT IN PRIMARY COOLANT SYSTEM DURING REACTOR COOLANT PUMP START-UP PERIOD
    Gao, Hong
    Gao, Feng
    Zhao, Xianchao
    Chen, Jie
    Cao, Xuewu
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2013, VOL 1C: SYMPOSIA, 2014,
  • [43] Influence of outlet edge position of guide vane on performance of well submersible pump
    Cheng X.
    Lü B.
    Zhang X.
    Wei Y.
    Zhang S.
    Wang P.
    2018, Chinese Society of Agricultural Engineering (34): : 68 - 75
  • [44] ROTARY VANE PUMP FOR DIFFERENTIAL CIRCULAR REACTOR
    MACAK, J
    LICKA, S
    CHEMICKE LISTY, 1971, 65 (11): : 1213 - &
  • [45] Influence mechanism of the non-uniform inflow on performance of reactor coolant pump
    Song, Yu
    Huang, Song
    Xu, Rui
    Zhang, Zhengchuan
    Yin, Junlian
    Wang, Dezhong
    ANNALS OF NUCLEAR ENERGY, 2023, 180
  • [46] Coupling model and performance analysis of hydrodynamic mechanical seal for reactor coolant pump
    Wang, Xiao-Yan
    Meng, Xiang-Kai
    Liu, Xin
    Sheng, Song-En
    Peng, Xu-Dong
    Meng, X.-K. (mengxk@zjut.edu.cn), 2013, Science Press (33): : 169 - 176
  • [47] Impact Of Diffuser Width On The Performance Of AP1000 Reactor Coolant Pump
    Yuan, Danqing
    Yan, Hua
    Wang, Peipei
    ELECTRICAL POWER & ENERGY SYSTEMS, PTS 1 AND 2, 2012, 516-517 : 921 - 925
  • [48] TRENDS AND EXPERIENCES IN REACTOR COOLANT PUMP MOTORS
    HOLTER, WG
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1980, 99 (04): : 1316 - 1316
  • [49] Optimization Design of the Weight of Reactor Coolant Pump
    Lv Xiang-bo
    Yan Chang-qi
    Li Gui-jing
    Wang Jian-jun
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [50] Study on Pressure Fluctuation and Radial Force during Startup of Reactor Coolant Pump
    Su S.
    Wang P.
    Xu Z.
    Ruan X.
    Kong W.
    Wang, Pengfei (wangpf@zucc.edu.cn), 1600, Atomic Energy Press (38): : 110 - 114