Guide vane angle and reactor coolant pump performance during idling

被引:1
|
作者
Ye, Daoxing [1 ,2 ]
Zhai, Fengli [1 ]
Luo, Yimin [1 ]
Wu, Jinchen [1 ]
Chen, Junlin [1 ]
Lai, Xide [1 ]
Tian, Wen [1 ]
机构
[1] Xihua Univ, Sch Energy & Power Engn, Chengdu 610039, Sichuan, Peoples R China
[2] Xihua Univ, Key Lab Fluid & Power Machinery, Minist Educ, Chengdu 610039, Sichuan, Peoples R China
关键词
Reactor coolant pump; Idling characteristics; External characteristics; Radial force; Blade load;
D O I
10.1016/j.anucene.2024.110720
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to study the influence of different guide vane angle variation on performance characteristics of reactor coolant pump (RCP) during idling process, the external characteristics of RCP model with five different guide vane angles at idling process state were analyzed. Radial force characteristics and blade load characteristics of RCP were analyzed. The results show that the head and torque changes of pump with different guide vane angles in different idle period are consistent. The head of DY1model (Guide vane angle increases sharply first and then decreases gently, which convexity is large) is the highest and torque is small. The head drop rate of DY5 model (Guide vane decreases first and then increases, and the concavity is large) is the highest and torque is the largest. With the idling, the radial force of impeller and guide vane decreases gradually. The radial force of DY5 model impeller is small and the fluctuation range is weak. The radial force of DY4 model (Guide vane shows concavity change with gentle increase) impeller before idling is the largest. In the nonlinear transition of idle period, the total radial force of DY4 model is 235 N when idling for 32 s, which is nearly 30 times lower than that before idling, and the radial force decreases the most. In different idling periods, the radial force amplitude of guide vane of DY5 model is the largest, and the radial force decrease amplitude of guide vane of DY4 model is the largest in the whole idling period. The impeller blade load of DY4 and DY5 model pumps with concavity guide vane angle change law is significantly higher than that of other model pumps after the relative position of streamline is 0.6. When the relative position of the guide vane along the streamline direction is less than 0.5, the load fluctuation of the guide vane of each model pump is large. When the relative position is greater than 0.5, the blade load fluctuation is relatively small.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Investigation of hydraulic performance in an axial-flow blood pump with different guide vane outlet angle
    Sang, Xiaohu
    Zhou, Xiaojun
    ADVANCES IN MECHANICAL ENGINEERING, 2017, 9 (08): : 1 - 11
  • [22] Influence of the blade angle of guide vane outlet on the performance of lifting electric pump in deep sea mining
    Liu Shaojun
    Yang Hengling
    Hu Xiaozhou
    Zhao He
    2019 INTERNATIONAL CONFERENCE ON INTELLIGENT TRANSPORTATION, BIG DATA & SMART CITY (ICITBS), 2019, : 517 - 523
  • [23] Influence of Circumferential Placement Position of Guide Vanes on Performance and Dynamic Characteristics of Nuclear Reactor Coolant Pump
    Cheng, Xiaorui
    Lv, Boru
    Ji, Chenying
    Jia, Ningning
    Dorah, N.
    MATHEMATICAL PROBLEMS IN ENGINEERING, 2020, 2020
  • [24] Impact of guide vane opening angle on the flow stability in a pump-turbine in pump mode
    Zhu, Di
    Xiao, Ruofu
    Tao, Ran
    Liu, Weichao
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART C-JOURNAL OF MECHANICAL ENGINEERING SCIENCE, 2017, 231 (13) : 2484 - 2492
  • [25] Hydraulic Performance Analysis and Optimization for the Impeller of Reactor Coolant Pump
    Jiang H.
    Zhou J.
    Liu L.
    Hedongli Gongcheng/Nuclear Power Engineering, 2019, 40 (05): : 41 - 45
  • [26] Influence of inflow directions and setting angle of inlet guide vane on hydraulic performance of an axial-flow pump
    Duc-Anh Nguyen
    Sang-Bum Ma
    Sung Kim
    Jin-Hyuk Kim
    Scientific Reports, 13
  • [27] Influence of inflow directions and setting angle of inlet guide vane on hydraulic performance of an axial-flow pump
    Nguyen, Duc-Anh
    Ma, Sang-Bum
    Kim, Sung
    Kim, Jin-Hyuk
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [28] Model for Calculating Idling of Nuclear Power Coolant Pump Considering Coolant Kinetic Energy in Pipeline
    Jiao Z.
    Cai L.
    Zhang L.
    Hu L.
    Liu X.
    Hedongli Gongcheng/Nuclear Power Engineering, 2022, 43 (01): : 48 - 51
  • [29] Influence of guide vane setting in pump mode on performance characteristics of a pump-turbine]
    Li, Deyou
    Wang, Hongjie
    Nielsen, Torbjorn K.
    Gong, Ruzhi
    Wei, Xianzhu
    Qin, Daqing
    28TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS (IAHR2016), PTS 1-12, 2016, 49
  • [30] Influence of guide vane setting in pump mode on performance characteristics of a pump-turbine
    Li D.
    Wang H.
    Nielsen T.K.
    Gong R.
    Wei X.
    Qin D.
    International Journal of Fluid Machinery and Systems, 2017, 10 (02) : 154 - 163