Guide vane angle and reactor coolant pump performance during idling

被引:1
|
作者
Ye, Daoxing [1 ,2 ]
Zhai, Fengli [1 ]
Luo, Yimin [1 ]
Wu, Jinchen [1 ]
Chen, Junlin [1 ]
Lai, Xide [1 ]
Tian, Wen [1 ]
机构
[1] Xihua Univ, Sch Energy & Power Engn, Chengdu 610039, Sichuan, Peoples R China
[2] Xihua Univ, Key Lab Fluid & Power Machinery, Minist Educ, Chengdu 610039, Sichuan, Peoples R China
关键词
Reactor coolant pump; Idling characteristics; External characteristics; Radial force; Blade load;
D O I
10.1016/j.anucene.2024.110720
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to study the influence of different guide vane angle variation on performance characteristics of reactor coolant pump (RCP) during idling process, the external characteristics of RCP model with five different guide vane angles at idling process state were analyzed. Radial force characteristics and blade load characteristics of RCP were analyzed. The results show that the head and torque changes of pump with different guide vane angles in different idle period are consistent. The head of DY1model (Guide vane angle increases sharply first and then decreases gently, which convexity is large) is the highest and torque is small. The head drop rate of DY5 model (Guide vane decreases first and then increases, and the concavity is large) is the highest and torque is the largest. With the idling, the radial force of impeller and guide vane decreases gradually. The radial force of DY5 model impeller is small and the fluctuation range is weak. The radial force of DY4 model (Guide vane shows concavity change with gentle increase) impeller before idling is the largest. In the nonlinear transition of idle period, the total radial force of DY4 model is 235 N when idling for 32 s, which is nearly 30 times lower than that before idling, and the radial force decreases the most. In different idling periods, the radial force amplitude of guide vane of DY5 model is the largest, and the radial force decrease amplitude of guide vane of DY4 model is the largest in the whole idling period. The impeller blade load of DY4 and DY5 model pumps with concavity guide vane angle change law is significantly higher than that of other model pumps after the relative position of streamline is 0.6. When the relative position of the guide vane along the streamline direction is less than 0.5, the load fluctuation of the guide vane of each model pump is large. When the relative position is greater than 0.5, the blade load fluctuation is relatively small.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Shutdown idling performance of the nuclear main coolant pump under station blackout accident: An optimization study
    Lu, Yonggang
    Zhao, Weiqiang
    Batllo, Alexandre Presas
    Zhu, Rongsheng
    Wang, Zhengwei
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2023, 237 (01) : 79 - 97
  • [32] Aerodynamic Performance of a Coolant Flow Off-Take Downstream of an Outlet Guide Vane
    A'Barrow, C.
    Carrotte, J. F.
    Walker, A. D.
    Rolt, A. M.
    JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2013, 135 (01):
  • [33] Influence of prewhirl angle on a centrifugal pump with inlet guide vane running at turbine mode
    Liu, Ming
    Tan, Lei
    Cao, ShuLiang
    29TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS, 2019, 240
  • [34] Analysis on the effect of variable guide vane numbers on the performance of pump as turbine
    Shi, FengXia
    Yang, JunHu
    Wang, XiaoHui
    ADVANCES IN MECHANICAL ENGINEERING, 2018, 10 (06):
  • [35] INTERACTIONAL EFFECTS OF INLET GUIDE VANE AND BLADE ANGLE ON HYDRAULIC PERFORMANCE CHARACTERISTICS OF A SUBMERSIBLE AXIAL-FLOW PUMP
    Kim, Youn-Sung
    Shim, Hyeon-Seok
    Kim, Kwang-Yong
    PROCEEDINGS OF THE ASME FLUIDS ENGINEERING DIVISION SUMMER MEETING, 2018, VOL 3, 2018,
  • [36] Effect of boric acid concentration on reactor coolant pump performance in PWRs
    Zhang, Ye
    Wang, Xiao-Fang
    Jie, Hong-En
    Hedongli Gongcheng/Nuclear Power Engineering, 2011, 32 (04): : 95 - 98
  • [37] Dynamic flow behavior and performance of a reactor coolant pump with distorted inflow
    Li, Yi-bin
    Fan, Zhao-jing
    Guo, Dong-sheng
    Li, Xiao-bin
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2020, 14 (01) : 683 - 699
  • [38] Numerical Analysis of reactor coolant pump performance under reverse conditions
    Ran, Hongjuan
    Qian, Xinru
    Shi, Tianjiao
    Wang, Dezhong
    30TH IAHR SYMPOSIUM ON HYDRAULIC MACHINERY AND SYSTEMS (IAHR 2020), 2021, 774
  • [39] ADVANCEMENT OF REACTOR COOLANT PUMP (RCP) PERFORMANCE VERIFICATION TEST IN KAERI
    Cho, Yun-Je
    Kim, Yeon-Sik
    Cho, Seok
    Kim, Seok
    Bae, Byoung-Unh
    Chung, Heung-June
    Youn, Young-Jung
    Park, Jong-Kuk
    Choi, Hae-Seob
    Jeon, Woo-Jin
    Kim, Bok-Deuk
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2B, 2014,
  • [40] The Cavitation Research in Reactor Coolant Pump
    Wang Wei
    Lu Peng-Bo
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,