Multisource cone beam computed tomography using a carbon nanotube x-ray source array

被引:0
|
作者
Xu, Shuang [1 ]
Hu, Yuanming [2 ]
Li, Boyuan [2 ]
Inscoe, Christina R. [2 ]
Tyndall, Donald A. [3 ]
Lee, Yueh Z. [4 ]
Lu, Jianping [2 ]
Zhou, Otto [2 ]
机构
[1] Univ N Carolina, Adams Sch Dent, Dept Appl Phys Sci, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Adams Sch Dent, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Adams Sch Dent, Div Diagnost Sci, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Sch Med, Dept Radiol, Chapel Hill, NC 27599 USA
来源
MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1 | 2024年 / 12925卷
关键词
Multisource CT; CBCT; CNT X-ray; HU uniformity; HU accuracy; cone beam artifacts; SCATTER CORRECTION; CT;
D O I
10.1117/12.3005571
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The purpose of this study is to develop and evaluate a functional multisource cone beam computed tomography (ms-CBCT) scanner to mitigate some of the main limitations of the current CBCT. The benchtop ms-CBCT utilizes a carbon nanotube (CNT) field emission source array to generate multiple narrowly collimated and rapidly scanning x-ray beams, each illuminating a section of the object and collectively covering the region of interest. A contrast phantom and a Defrise phantom were imaged by the ms-CBCT, the ms-CBCT operating in the convetional CBCT configuration, and a clinical CBCT. The results show the ms-CBCT reduces the spatial nonuniformity and root-mean-square error (RMSE) of the CT HU values by respectively 75% and 60%, essentially eliminates the cone beam artifacts, increases the effective axial coverage, and improves the CNR by 30% similar to 50% compared to the conventional CBCT at a comparable imaging dose. The results show that the ms-CBCT can potentially provides the performance of an MDCT while maintaining the essential attributes of a CBCT including volumetric imaging, low dose, affordability, and compact design.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Drastic Performance Improvement of a Polychromatic Cone-Beam X-Ray Fluorescence Computed Tomography (XFCT) System Using a Kilowatt-Range X-Ray Source
    Manohar, N.
    Reynoso, F.
    Cho, S.
    MEDICAL PHYSICS, 2015, 42 (06) : 3716 - 3716
  • [22] Multisource X-Ray System for Artifact Reduction in Cone Beam CT
    Becker, A.
    Hernandez, A.
    Schwoebel, P.
    Boone, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3177 - 3178
  • [23] Stationary chest tomosynthesis using a carbon nanotube x-ray source array: a feasibility study
    Shan, Jing
    Tucker, Andrew W.
    Lee, Yueh Z.
    Heath, Michael D.
    Wang, Xiaohui
    Foos, David H.
    Lu, Jianping
    Zhou, Otto
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 81 - 100
  • [24] Characterization of Scattered X-Ray Photons in Dental Cone-Beam Computed Tomography
    Yang, Ching-Ching
    PLOS ONE, 2016, 11 (03):
  • [25] Efficiency of Piecewise Polyline Planar X-Ray Detectors for Cone Beam Computed Tomography
    Miroshnichenko, S.
    Ukho, N.
    2015 IEEE 35TH INTERNATIONAL CONFERENCE ON ELECTRONICS AND NANOTECHNOLOGY (ELNANO), 2015, : 381 - 383
  • [26] Characterization of spectral x-ray imaging for dental cone-beam computed tomography
    Nasirudin, Radin Adi Aizudin Bin Radin
    Penchev, Petar
    Mei, Kai
    Rummeny, Ernst J.
    Fiebich, Martin
    Noel, Peter B.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [27] Characterization of spectral X-ray imaging for dental cone-beam computed tomography
    Nasirudin, Radin Adi Aizudin Bin Radin
    Penchev, Petar
    Mei, Kai
    Rummeny, Ernst J.
    Fiebich, Martin
    Noël, Peter B.
    Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 2013, 8668
  • [28] Cone beam X-ray luminescence computed tomography reconstruction with a priori anatomical information
    Lo, Pei-An
    Lin, Meng-Lung
    Jin, Shih-Chun
    Chen, Jyh-Cheng
    Lin, Syue-Liang
    Chang, C. Allen
    Chiang, Huihua Kenny
    REFLECTION, SCATTERING, AND DIFFRACTION FROM SURFACES IV, 2014, 9205
  • [29] Dynamic cone beam X-ray luminescence computed tomography with principal component analysis
    Gao, Peng
    Rong, Junyan
    Liu, Tianshuai
    Zhang, Wenli
    Pu, Huangsheng
    Zhang, Yuanke
    Lu, Hongbing
    MEDICAL IMAGING 2018: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2018, 10578
  • [30] Parallel computing methods for X-ray cone beam tomography with large array sizes
    Reimann, DA
    Flynn, MJ
    Chaudhary, V
    Sethi, IK
    1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, : 1710 - 1713