Multisource cone beam computed tomography using a carbon nanotube x-ray source array

被引:0
|
作者
Xu, Shuang [1 ]
Hu, Yuanming [2 ]
Li, Boyuan [2 ]
Inscoe, Christina R. [2 ]
Tyndall, Donald A. [3 ]
Lee, Yueh Z. [4 ]
Lu, Jianping [2 ]
Zhou, Otto [2 ]
机构
[1] Univ N Carolina, Adams Sch Dent, Dept Appl Phys Sci, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Adams Sch Dent, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Adams Sch Dent, Div Diagnost Sci, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Sch Med, Dept Radiol, Chapel Hill, NC 27599 USA
关键词
Multisource CT; CBCT; CNT X-ray; HU uniformity; HU accuracy; cone beam artifacts; SCATTER CORRECTION; CT;
D O I
10.1117/12.3005571
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The purpose of this study is to develop and evaluate a functional multisource cone beam computed tomography (ms-CBCT) scanner to mitigate some of the main limitations of the current CBCT. The benchtop ms-CBCT utilizes a carbon nanotube (CNT) field emission source array to generate multiple narrowly collimated and rapidly scanning x-ray beams, each illuminating a section of the object and collectively covering the region of interest. A contrast phantom and a Defrise phantom were imaged by the ms-CBCT, the ms-CBCT operating in the convetional CBCT configuration, and a clinical CBCT. The results show the ms-CBCT reduces the spatial nonuniformity and root-mean-square error (RMSE) of the CT HU values by respectively 75% and 60%, essentially eliminates the cone beam artifacts, increases the effective axial coverage, and improves the CNR by 30% similar to 50% compared to the conventional CBCT at a comparable imaging dose. The results show that the ms-CBCT can potentially provides the performance of an MDCT while maintaining the essential attributes of a CBCT including volumetric imaging, low dose, affordability, and compact design.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Fluorescence X-ray Computed Tomography Using CdTe Detector Array
    Yoon, Changyeon
    Lee, Wonho
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [32] Calibration of a Coil Array Geometry Using an X-Ray Computed Tomography
    Oyama, Daisuke
    Adachi, Yoshiaki
    Higuchi, Masanori
    Uehara, Gen
    IEEE TRANSACTIONS ON MAGNETICS, 2022, 58 (02)
  • [33] Multibeam X-Ray Source Array Based on Carbon Nanotube Field Emission
    Zhou, O.
    Lu, J.
    Calderon-Colon, X.
    Qian, X.
    Yang, G.
    Cao, G.
    Gidcumb, E.
    Tucker, A.
    Shan, J.
    Spronk, D.
    Sprenger, F.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [34] Metal Artifact Reduction in Cone-Beam X-Ray Computed Tomography Using Statistical Iterative Reconstruction
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    ECTI-CON 2008: PROCEEDINGS OF THE 2008 5TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY, VOLS 1 AND 2, 2008, : 493 - +
  • [35] Quasimonochromatic x-ray computed tomography by the balanced filter method using a conventional x-ray source
    Saito, M
    MEDICAL PHYSICS, 2004, 31 (12) : 3436 - 3443
  • [36] Development of high-speed micro computed tomography system based on carbon nanotube emitter x-ray source
    Kim, Wooseob
    Jung, Jaeik
    Rajpoot, Shalini
    Chung, Weon-Kuu
    Ahn, Jeungsun
    Lee, Byeong-No
    Ryu, Jehwang
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [37] A cone-beam X-ray computed tomography data collection designed for machine learning
    Sarkissian, Henri Der
    Lucka, Felix
    van Eijnatten, Maureen
    Colacicco, Giulia
    Coban, Sophia Bethany
    Batenburg, Kees Joost
    SCIENTIFIC DATA, 2019, 6 (1)
  • [38] Overview of X-ray Scatter in Cone-beam Computed Tomography and Its Correction Methods
    Niu, Tianye
    Zhu, Lei
    CURRENT MEDICAL IMAGING REVIEWS, 2010, 6 (02) : 82 - 89
  • [39] ALGORITHM OF RECONSTRUCTION OF THREE-DIMENSIONAL IMAGES IN X-RAY COMPUTED TOMOGRAPHY WITH A CONE BEAM
    Simonov, E.
    Prokhorov, A., V
    BULLETIN OF THE SOUTH URAL STATE UNIVERSITY SERIES-MATHEMATICAL MODELLING PROGRAMMING & COMPUTER SOFTWARE, 2021, 14 (01): : 104 - 117
  • [40] X-ray Cone-Beam Breast Computed Tomography: Phantoms Studies on Microcalcifications Visibility
    Lauria, Adele
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Russo, Paolo
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 3965 - 3969