Multisource cone beam computed tomography using a carbon nanotube x-ray source array

被引:0
|
作者
Xu, Shuang [1 ]
Hu, Yuanming [2 ]
Li, Boyuan [2 ]
Inscoe, Christina R. [2 ]
Tyndall, Donald A. [3 ]
Lee, Yueh Z. [4 ]
Lu, Jianping [2 ]
Zhou, Otto [2 ]
机构
[1] Univ N Carolina, Adams Sch Dent, Dept Appl Phys Sci, Chapel Hill, NC 27599 USA
[2] Univ N Carolina, Adams Sch Dent, Dept Phys & Astron, Chapel Hill, NC 27599 USA
[3] Univ N Carolina, Adams Sch Dent, Div Diagnost Sci, Chapel Hill, NC 27599 USA
[4] Univ N Carolina, Sch Med, Dept Radiol, Chapel Hill, NC 27599 USA
关键词
Multisource CT; CBCT; CNT X-ray; HU uniformity; HU accuracy; cone beam artifacts; SCATTER CORRECTION; CT;
D O I
10.1117/12.3005571
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The purpose of this study is to develop and evaluate a functional multisource cone beam computed tomography (ms-CBCT) scanner to mitigate some of the main limitations of the current CBCT. The benchtop ms-CBCT utilizes a carbon nanotube (CNT) field emission source array to generate multiple narrowly collimated and rapidly scanning x-ray beams, each illuminating a section of the object and collectively covering the region of interest. A contrast phantom and a Defrise phantom were imaged by the ms-CBCT, the ms-CBCT operating in the convetional CBCT configuration, and a clinical CBCT. The results show the ms-CBCT reduces the spatial nonuniformity and root-mean-square error (RMSE) of the CT HU values by respectively 75% and 60%, essentially eliminates the cone beam artifacts, increases the effective axial coverage, and improves the CNR by 30% similar to 50% compared to the conventional CBCT at a comparable imaging dose. The results show that the ms-CBCT can potentially provides the performance of an MDCT while maintaining the essential attributes of a CBCT including volumetric imaging, low dose, affordability, and compact design.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] A carbon nanotube x-ray source array designed for a new multisource cone beam computed tomography scanner
    Li, Boyuan
    Inscoe, Christina R.
    Xu, Shuang
    Capo, Timothy
    Tyndall, Donald A.
    Lee, Yueh Z.
    Lu, Jianping
    Zhou, Otto
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (07):
  • [2] Evaluation of carbon nanotube x-ray source array for stationary head computed tomography
    Spronk, Derrek
    Luo, Yueting
    Inscoe, Christina R.
    Lee, Yueh Z.
    Lu, Jianping
    Zhou, Otto
    MEDICAL PHYSICS, 2021, 48 (03) : 1089 - 1099
  • [3] Volumetric computed tomography with carbon nanotube X-ray source array for improved image quality and accuracy
    Shuang Xu
    Yuanming Hu
    Boyuan Li
    Christina R. Inscoe
    Donald A. Tyndall
    Yueh Z. Lee
    Jianping Lu
    Otto Zhou
    Communications Engineering, 2 (1):
  • [4] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [5] Development of Carbon Nanotube X-ray System for Computed Tomography
    Ryu, Je Hwang
    Lee, Seung Ho
    Kim, Wan Sun
    Eom, Young Ju
    Kim, Jae Gon
    Lee, Soo Yeol
    Park, Kyu Chang
    Park, Hun Kuk
    2012 25TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2012, : 402 - +
  • [6] Optimal specimen placement in cone beam X-ray computed tomography
    Heinzl, C.
    Kastner, J.
    Amirkhamov, A.
    Groeller, E.
    Gusenbauer, C.
    NDT & E INTERNATIONAL, 2012, 50 : 42 - 49
  • [7] Cone beam x-ray luminescence computed tomography: A feasibility study
    Chen, Dongmei
    Zhu, Shouping
    Yi, Huangjian
    Zhang, Xianghan
    Chen, Duofang
    Liang, Jimin
    Tian, Jie
    MEDICAL PHYSICS, 2013, 40 (03)
  • [8] Optimization of Ballasted Carbon Nanotube Array for X-ray Source
    Sun, Yonghai
    Yeow, John T. W.
    Jaffray, David A.
    2013 13TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2013, : 389 - 392
  • [9] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [10] Cone-beam x-ray luminescence computed tomography based on x-ray absorption dosage
    Liu, Tianshuai
    Rong, Junyan
    Gao, Peng
    Zhang, Wenli
    Liu, Wenlei
    Zhang, Yuanke
    Lu, Hongbing
    JOURNAL OF BIOMEDICAL OPTICS, 2018, 23 (02)