Optimization of Ballasted Carbon Nanotube Array for X-ray Source

被引:0
|
作者
Sun, Yonghai [1 ]
Yeow, John T. W. [1 ]
Jaffray, David A. [2 ]
机构
[1] Univ Waterloo, Dept Syst Design Engn, Waterloo, ON N2L 3G1, Canada
[2] Princess Margaret Hosp, Radiat Dept, Toronto, ON M5G 2M9, Canada
关键词
FIELD-EMISSION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Ballast resistor under layer can improve reliability and stability of field emission cathode. Utilization of ballast resistor in Spindt cathode has been studied thoroughly. However, due to the significant difference between the Spindt cathode and CNT (carbon nanotube) emitter, studies of ballasted CNT emitter array are rare. Ballasted CNT emitter array has been demonstrated in our early studies. In this article, we use the finite element method to analyses the effect of the geometry parameters of the emission array. Optimized parameters, for example: intertube pitch, connection pad diameter, resistor layer thickness, and height of the CNT, are calculated. These optimized parameters are suitable for ballasted CNT emitter arrays for flat panel X-ray sources.
引用
收藏
页码:389 / 392
页数:4
相关论文
共 50 条
  • [1] Ballasted Carbon Nanotube Array based X-ray Tube
    Sun, Yonghai
    Yeow, John T. W.
    Jaffray, David A.
    2012 12TH IEEE CONFERENCE ON NANOTECHNOLOGY (IEEE-NANO), 2012,
  • [2] Multibeam X-Ray Source Array Based on Carbon Nanotube Field Emission
    Zhou, O.
    Lu, J.
    Calderon-Colon, X.
    Qian, X.
    Yang, G.
    Cao, G.
    Gidcumb, E.
    Tucker, A.
    Shan, J.
    Spronk, D.
    Sprenger, F.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [3] Stationary intraoral digital tomosynthesis using a carbon nanotube X-ray source array
    Shan, J.
    Tucker, A. W.
    Gaalaas, L. R.
    Wu, G.
    Platin, E.
    Mol, A.
    Lu, J.
    Zhou, O.
    DENTOMAXILLOFACIAL RADIOLOGY, 2015, 44 (09)
  • [4] A carbon nanotube field emission multipixel x-ray array source for microradiotherapy application
    Wang, Sigen
    Calderon, Xiomara
    Peng, Rui
    Schreiber, Eric C.
    Zhou, Otto
    Chang, Sha
    APPLIED PHYSICS LETTERS, 2011, 98 (21)
  • [5] Evaluation of carbon nanotube x-ray source array for stationary head computed tomography
    Spronk, Derrek
    Luo, Yueting
    Inscoe, Christina R.
    Lee, Yueh Z.
    Lu, Jianping
    Zhou, Otto
    MEDICAL PHYSICS, 2021, 48 (03) : 1089 - 1099
  • [6] Multisource cone beam computed tomography using a carbon nanotube x-ray source array
    Xu, Shuang
    Hu, Yuanming
    Li, Boyuan
    Inscoe, Christina R.
    Tyndall, Donald A.
    Lee, Yueh Z.
    Lu, Jianping
    Zhou, Otto
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [7] Stationary chest tomosynthesis using a carbon nanotube x-ray source array: a feasibility study
    Shan, Jing
    Tucker, Andrew W.
    Lee, Yueh Z.
    Heath, Michael D.
    Wang, Xiaohui
    Foos, David H.
    Lu, Jianping
    Zhou, Otto
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (01): : 81 - 100
  • [8] Development of carbon nanotube field emitters for x-ray source
    Calderon-Colon, Xiomara
    Zhou, Otto
    PROCEEDING OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2007, 2007, : 549 - 550
  • [9] Orthogonal Tomosynthesis for Whole Body Skeletal Imaging Enabled by Carbon Nanotube X-ray Source Array
    Thapa, Diwash
    Billingsley, Alex
    Luo, Yueting
    Inscoe, Christina R.
    Zhou, Otto
    Lu, Jianping
    Lee, Yueh Z.
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [10] Volumetric computed tomography with carbon nanotube X-ray source array for improved image quality and accuracy
    Shuang Xu
    Yuanming Hu
    Boyuan Li
    Christina R. Inscoe
    Donald A. Tyndall
    Yueh Z. Lee
    Jianping Lu
    Otto Zhou
    Communications Engineering, 2 (1):