UTILIZING STENT WALL SHEAR STRESS TO ASSESS STENT AND FLOW DIVERTER PERFORMANCE FOR TREATING INTRACRANIAL ANEURYSMS

被引:0
|
作者
Suess, Taylor N. [1 ]
Gent, Stephen P. [1 ]
机构
[1] South Dakota State Univ, Dept Mech Engn, Brookings, SD 57007 USA
关键词
flow diverter; stent; computational fluid dynamics; CFD; wall shear stress; HEMODYNAMICS; RUPTURE; OCCLUSION; MODEL;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Analysis of flow diverting intracranial aneurysm repair devices has traditionally focused on reducing intrasaccular blood flow velocity and aneurysm wall shear stress (WSS) as the primary metrics for improved perceived device performance. However, the interpretation of this data has been debated, particularly with regards to the specific biological benefits of high or low aneurysm WSS. Therefore, this research proposes an additional parameter of WSS at the stent struts that could provide valuable insight regarding the device's potential to promote occlusion at the aneurysm neck by indicating potential locations of increased platelet activation and microparticle shedding. Fluid flow effects were evaluated for two flow diverters (Pipeline (TM) and FRED (TM)) and three stents (Enterprise, Atlas (TM), and LVIS (TM)) using computational fluid dynamics (CFD) models developed from two patient-derived CTA datasets with aneurysms in the middle cerebral artery (MCA) and basilar artery (BA), respectively. The device WSS data provides an additional metric for evaluating the ability of the device to constrain the blood flow within the main vessel, as well as determining the point at which the blood flow is released into the aneurysm, indicating the potential locations of the initiation of aneurysm occlusion. It is hypothesized that high device WSS close to the aneurysm neck creates a higher likelihood of aneurysm occlusion due to platelet activation and microparticle shedding, while high device WSS proximal on the device would indicate higher likelihood of undesirable daughter vessel occlusion. Conversely, low-to-moderate device WSS throughout the device length could be interpreted as less flow diversion and more consistent blood flow allowed into the aneurysm, resulting in lesser device performance.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Stent Implantation Influence Wall Shear Stress Evolution
    Bernad, S. I.
    Totorean, A. F.
    Bosioc, A. I.
    Petre, I.
    Bernad, E. S.
    PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON NUMERICAL ANALYSIS AND APPLIED MATHEMATICS 2015 (ICNAAM-2015), 2016, 1738
  • [42] Endovascular treatment of wide-necked paraophthalmic aneurysms with flow diverter stent implantation
    Guzeldag, Hamit
    Onan, Bilen
    Piskin, Ferhat Can
    Sozutok, Sinan
    CUKUROVA MEDICAL JOURNAL, 2021, 46 (04): : 1666 - 1674
  • [43] HIGH WALL SHEAR STRESS AND POSITIVE WALL SHEAR STRESS GRADIENT TRIGGER THE INITIATION OF INTRACRANIAL ANEURYSMS
    Metaxa, Eleni
    Tremmel, Markus
    Xiang, Jianping
    Kolega, John
    Mandelbaum, Max
    Siddiqui, Adnan
    Mocco, J.
    Meng, Hui
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE - 2009, PT A AND B, 2009, : 523 - 524
  • [44] Silk flow-diverter stent for the treatment of complex intracranial aneurysms: A one-year follow-up multicenter study
    Foa Torres, G.
    Roca, F.
    Noguera, A.
    Godes, J.
    Petrocelli, S.
    Aznar, I.
    Ales, S.
    Muszynski, P.
    Maehara, R.
    Vicente, M.
    Pumar, J. M.
    INTERVENTIONAL NEURORADIOLOGY, 2018, 24 (04) : 357 - 362
  • [45] Flow diverter versus stent-assisted coiling treatment for managing dissecting intracranial aneurysms: A systematic review and meta-analysis
    Brenner, Leonardo O.
    Prestes, Milena Zadra
    Soares, Cid
    Romeiro, Pedro
    Gomez, Victor A.
    Rabelo, Nicollas Nunes
    Welling, Leonardo C.
    Koester, Stefan W.
    Pinheiro, Agostinho C.
    Batista, Savio
    Bertani, Raphael
    Figueiredo, Eberval Gadelha
    Cavalcanti, Daniel Dutra
    INTERVENTIONAL NEURORADIOLOGY, 2024,
  • [46] A rare but morbid neurosurgical target: petrous aneurysms and their endovascular management in the stent/flow diverter era
    Gross, Bradley A.
    Moon, Karam
    Ducruet, Andrew F.
    Albuquerque, Felipe C.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (04) : 381 - +
  • [47] Influence of stent flexibility on artery wall stress and wall shear stress in bifurcation lesions
    Saito, Noboru
    Mori, Yuhei
    Komatsu, Tomoya
    Medical Devices: Evidence and Research, 2020, 13 : 365 - 375
  • [48] Influence of Stent Flexibility on Artery Wall Stress and Wall Shear Stress in Bifurcation Lesions
    Saito, Noboru
    Mori, Yuhei
    Komatsu, Tomoya
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2020, 13 : 365 - 375
  • [49] Does Arterial Flow Rate Affect the Assessment of Flow-Diverter Stent Performance?
    Morales, H. G.
    Bonnefous, O.
    Geers, A. J.
    Brina, O.
    Pereira, V. M.
    Spelle, L.
    Moret, J.
    Larrabide, I.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (12) : 2293 - 2298
  • [50] Flow Diverter Performance for the Treatment of Intracranial Aneurysms: An International Multicenter Comparative Study
    Vivanco-Suarez, Juan
    Basilio Flores, Juan E.
    Rodriguez-Calienes, Aaron
    Carlos Miranda, Juan
    Foa, Gustavo
    Altschul, David
    Aguilar-Melgar, Joel A.
    Dajles, Andres
    Galecio-Castillo, Milagros
    Zevallos, Cynthia B.
    Farooqui, Mudassir
    Puri, Ajit S.
    Pacheco-Fernandez Baca, Henry
    Ortega-Gutierrez, Santiago
    STROKE-VASCULAR AND INTERVENTIONAL NEUROLOGY, 2023, 3 (02):