Stent Implantation Influence Wall Shear Stress Evolution

被引:0
|
作者
Bernad, S. I. [1 ]
Totorean, A. F. [2 ]
Bosioc, A. I. [2 ]
Petre, I. [3 ]
Bernad, E. S. [3 ]
机构
[1] Romanian Acad, Timisoara Branch, Mihai Viteazul Str 24, RO-300223 Timisoara, Romania
[2] Univ Politehn Timisoara, Dept Hydraul Machinery, Mihai Viteazul Str 1, RO-300222 Timisoara, Romania
[3] Univ Med & Pharm Victor Babes Timisoara, P Ta Eftimie Murgu 2, Timisoara, Romania
关键词
coronary stent; secondary flow; wall shear stress; recirculation;
D O I
10.1063/1.4951783
中图分类号
O29 [应用数学];
学科分类号
070104 ;
摘要
Local hemodynamic factors are known affect the natural history of the restenosis critically after coronary stenting of atherosclerosis. Stent-induced flows disturbance magnitude dependent directly on the strut design. The impact of flow alterations around struts vary as the strut geometrical parameters change. Our results provide data regarding the hemodynamic parameters for the blood flow in both stenosed and stented coronary artery under physiological conditions, namely wall shear stress and pressure drop.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Influence of stent flexibility on artery wall stress and wall shear stress in bifurcation lesions
    Saito, Noboru
    Mori, Yuhei
    Komatsu, Tomoya
    Medical Devices: Evidence and Research, 2020, 13 : 365 - 375
  • [2] Influence of Stent Flexibility on Artery Wall Stress and Wall Shear Stress in Bifurcation Lesions
    Saito, Noboru
    Mori, Yuhei
    Komatsu, Tomoya
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2020, 13 : 365 - 375
  • [3] Coronary artery stent implantation alters wall shear stress during maximal vasodilation
    LaDisa, JF
    Olson, LE
    Guler, I
    Gross, ER
    Hettrick, DA
    Kersten, JR
    Warltier, DC
    Pagel, PS
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1228 - 1229
  • [4] Wall shear stress in the development of in-stent restenosis revisited. A critical review of clinical data on shear stress after intracoronary stent implantation
    Jenei, Csaba
    Balogh, Emilia
    Szabo, Gabor Tamas
    Dezsi, Csaba Andras
    Koszegi, Zsolt
    CARDIOLOGY JOURNAL, 2016, 23 (04) : 365 - 373
  • [5] Impact of stent implantation on endothelial shear stress
    Economou, F.
    Katranas, S.
    Giannoglou, G.
    Gemitzis, K.
    Styliadis, I.
    Efthimiadis, G.
    Karvounis, H.
    Ziakas, A.
    HERZ, 2017, 42 (05) : 505 - 508
  • [6] Stent implantation alters coronary artery hemodynamics and wall shear stress during maximal vasodilation
    LaDisa, JF
    Hettrick, DA
    Olson, LE
    Guler, I
    Gross, ER
    Kress, TT
    Kersten, JR
    Warltier, DC
    Pagel, PS
    JOURNAL OF APPLIED PHYSIOLOGY, 2002, 93 (06) : 1939 - 1946
  • [7] Augmentation of wall shear stress inhibits neo intimal hyperplasia and inflammation after stent implantation
    Krams, R
    Van Damme, LCA
    Blommerde, CP
    Wentzel, JJ
    Stager, C
    Knaapen, MWM
    Serruys, PW
    EUROPEAN HEART JOURNAL, 2003, 24 : 427 - 427
  • [8] Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study
    Kumar, Sonali
    Molony, David
    Khawaja, Sameer
    Crawford, Kaylyn
    Thompson, Elizabeth W.
    Hung, Olivia
    Shah, Imran
    Navas-Simbana, Jessica
    Ho, Arlen
    Kumar, Arnav
    Ko, Yi-An
    Hosseini, Hossein
    Lefieux, Adrien
    Lee, Joo Myung
    Hahn, Joo-Yong
    Chen, Shao-Liang
    Otake, Hiromasa
    Akasaka, Takashi
    Shin, Eun-Seok
    Koo, Bon-Kwon
    Stankovic, Goran
    Milasinovic, Dejan
    Nam, Chang-Wook
    Won, Ki-Bum
    Escaned, Javier
    Erglis, Andrejs
    Murasato, Yoshinobu
    Veneziani, Alessandro
    Samady, Habib
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2023, 39 (07): : 1375 - 1382
  • [9] Stent underexpansion is associated with high wall shear stress: a biomechanical analysis of the shear stent study
    Sonali Kumar
    David Molony
    Sameer Khawaja
    Kaylyn Crawford
    Elizabeth W. Thompson
    Olivia Hung
    Imran Shah
    Jessica Navas-Simbana
    Arlen Ho
    Arnav Kumar
    Yi-An Ko
    Hossein Hosseini
    Adrien Lefieux
    Joo Myung Lee
    Joo-Yong Hahn
    Shao-Liang Chen
    Hiromasa Otake
    Takashi Akasaka
    Eun-Seok Shin
    Bon-Kwon Koo
    Goran Stankovic
    Dejan Milasinovic
    Chang-Wook Nam
    Ki-Bum Won
    Javier Escaned
    Andrejs Erglis
    Yoshinobu Murasato
    Alessandro Veneziani
    Habib Samady
    The International Journal of Cardiovascular Imaging, 2023, 39 : 1375 - 1382
  • [10] Stent Underexpansion Is Associated With High Wall Shear Stress: A Biomechanical Analysis of the Shear Stent Study
    Kumar, Sonali
    Molony, David
    Crawford, Kaylyn
    Dunn, Ryan
    Thompson, Elizabeth
    Eshtehardi, Parham
    Hung, Olivia
    Khawaja, Sameer
    Shah, Imran
    Simbana, Jessica Navas
    Kumar, Arnav
    Ko, Yi-An
    Lefieux, Adrien
    Lee, Joo Myung
    Machado, Kalina
    Sharma, Ashish
    Gupta, Sonu
    Chen, Shao-Liang
    Otake, Hiromasa
    Akasaka, Takashi
    Shin, Eun-Seok
    Koo, Bon-Kwon
    Stankovic, Goran
    Nam, Chang-Wook
    Escaned, Javier
    Erglis, Andrejs
    King, Spencer, III
    Alessandro, Veneziani
    Giddens, Don
    Samady, Habib
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B172 - B172