UTILIZING STENT WALL SHEAR STRESS TO ASSESS STENT AND FLOW DIVERTER PERFORMANCE FOR TREATING INTRACRANIAL ANEURYSMS

被引:0
|
作者
Suess, Taylor N. [1 ]
Gent, Stephen P. [1 ]
机构
[1] South Dakota State Univ, Dept Mech Engn, Brookings, SD 57007 USA
关键词
flow diverter; stent; computational fluid dynamics; CFD; wall shear stress; HEMODYNAMICS; RUPTURE; OCCLUSION; MODEL;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Analysis of flow diverting intracranial aneurysm repair devices has traditionally focused on reducing intrasaccular blood flow velocity and aneurysm wall shear stress (WSS) as the primary metrics for improved perceived device performance. However, the interpretation of this data has been debated, particularly with regards to the specific biological benefits of high or low aneurysm WSS. Therefore, this research proposes an additional parameter of WSS at the stent struts that could provide valuable insight regarding the device's potential to promote occlusion at the aneurysm neck by indicating potential locations of increased platelet activation and microparticle shedding. Fluid flow effects were evaluated for two flow diverters (Pipeline (TM) and FRED (TM)) and three stents (Enterprise, Atlas (TM), and LVIS (TM)) using computational fluid dynamics (CFD) models developed from two patient-derived CTA datasets with aneurysms in the middle cerebral artery (MCA) and basilar artery (BA), respectively. The device WSS data provides an additional metric for evaluating the ability of the device to constrain the blood flow within the main vessel, as well as determining the point at which the blood flow is released into the aneurysm, indicating the potential locations of the initiation of aneurysm occlusion. It is hypothesized that high device WSS close to the aneurysm neck creates a higher likelihood of aneurysm occlusion due to platelet activation and microparticle shedding, while high device WSS proximal on the device would indicate higher likelihood of undesirable daughter vessel occlusion. Conversely, low-to-moderate device WSS throughout the device length could be interpreted as less flow diversion and more consistent blood flow allowed into the aneurysm, resulting in lesser device performance.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Stent Underexpansion Is Associated With High Wall Shear Stress: A Biomechanical Analysis of the Shear Stent Study
    Kumar, Sonali
    Molony, David
    Crawford, Kaylyn
    Dunn, Ryan
    Thompson, Elizabeth
    Eshtehardi, Parham
    Hung, Olivia
    Khawaja, Sameer
    Shah, Imran
    Simbana, Jessica Navas
    Kumar, Arnav
    Ko, Yi-An
    Lefieux, Adrien
    Lee, Joo Myung
    Machado, Kalina
    Sharma, Ashish
    Gupta, Sonu
    Chen, Shao-Liang
    Otake, Hiromasa
    Akasaka, Takashi
    Shin, Eun-Seok
    Koo, Bon-Kwon
    Stankovic, Goran
    Nam, Chang-Wook
    Escaned, Javier
    Erglis, Andrejs
    King, Spencer, III
    Alessandro, Veneziani
    Giddens, Don
    Samady, Habib
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2020, 76 (17) : B172 - B172
  • [32] Letter by Pierot Regarding Article "Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms"
    Pierot, Laurent
    STROKE, 2011, 42 (03) : E38 - E39
  • [33] Response to Letter Regarding Article "Flow-Diverter Stent for the Endovascular Treatment of Intracranial Aneurysms: A Prospective Study in 29 Patients With 34 Aneurysms"
    Lubicz, Boris
    STROKE, 2011, 42 (03) : E40 - E40
  • [34] Wall shear stress in intracranial aneurysms and adjacent arteries
    Fuyu Wang
    Bainan Xu
    Zhenghui Sun
    Chen Wu
    Xiaojun Zhang
    NeuralRegenerationResearch, 2013, 8 (11) : 1007 - 1015
  • [35] Wall shear stress in intracranial aneurysms and adjacent arteries
    Wang, Fuyu
    Xu, Bainan
    Sun, Zhenghui
    Wu, Chen
    Zhang, Xiaojun
    NEURAL REGENERATION RESEARCH, 2013, 8 (11) : 1007 - 1015
  • [36] Morphological Effect on Wall Shear Stress in Intracranial Aneurysms
    Qiu, Tian-Lun
    Jin, Guo-Liang
    Bao, Wu-Qiao
    Lu, Hai-Tao
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2018, 79 (02) : 108 - 115
  • [37] Endovascular Treatment of Wide Necked Ruptured Saccular Aneurysms with Flow-Diverter Stent
    Duman, Enes
    Coven, Ilker
    Yildirim, Erkan
    Yilmaz, Cem
    Pinar, H. Ulas
    TURKISH NEUROSURGERY, 2017, 27 (03) : 362 - 367
  • [38] Silk Flow-Diverter Stent for the Treatment of Intracranial Aneurysms: A Series of 58 Patients with Emphasis on Long-Term Results
    Lubicz, B.
    Van der Elst, O.
    Collignon, L.
    Mine, B.
    Alghamdi, F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (03) : 542 - 546
  • [39] New Variable Porosity Flow Diverter (VPOD) Stent Design for Treatment of Cerebrovascular Aneurysms
    Suri, H.
    Ionita, C. N.
    Baier, R. E.
    Rudin, S.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1105 - 1108
  • [40] Flow-Diverter Silk Stent for the Treatment of Intracranial Aneurysms: 1-year Follow-Up in a Multicenter Study
    Berge, J.
    Biondi, A.
    Machi, P.
    Brunel, H.
    Pierot, L.
    Gabrillargues, J.
    Kadziolka, K.
    Barreau, X.
    Dousset, V.
    Bonafe, A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (06) : 1150 - 1155