Removal of leads broken during extraction: A comparison of different approaches and tools

被引:0
|
作者
Kutarski, Andrzej [1 ]
Jachec, Wojciech [2 ]
Pietura, Radoslaw [3 ]
Stefanczyk, Pawel [4 ]
Kosior, Jaroslaw [5 ]
Czakowski, Marek [6 ]
Sawonik, Sebastian [1 ]
Tulecki, Lukasz [7 ]
Nowosielecka, Dorota [4 ,7 ]
机构
[1] Med Univ Lublin, Dept Cardiol, Lublin, Poland
[2] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, Katowice, Poland
[3] Med Univ Lublin, Dept Radiog, Lublin, Poland
[4] Pope John Paul II Prov Hosp, Dept Cardiol, Zamosc, Poland
[5] Masovian Specialist Hosp Radom, Dept Cardiol, Radom, Poland
[6] Med Univ Lublin, Med Univ, Dept Cardiac Surg, Lublin, Poland
[7] Pope John Paul II Prov Hosp, Dept Cardiac Surg, Al Jana Pawla II 10, PL-22400 Zamosc, Poland
关键词
femoral approach; incomplete lead extraction; lead fragment removal; techniques of lead fragment removal; transvenous lead extraction; EXPERT CONSENSUS STATEMENT; PACEMAKER LEAD; ELECTRODE FRAGMENT; MANAGEMENT; EMBOLIZATION; PREDICTORS; EXPERIENCE; RETRIEVAL; MIGRATION; OUTCOMES;
D O I
10.1111/jce.16398
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Extraction of a broken lead fragment (BLF) has received scant attention in the literature. Methods: Retrospective analysis was to compare the effectiveness of different approaches and tools used for BLF removal during 127 procedures. Results: A superior approach was the most popular (75.6%), femoral (15.7%) and combined (8.7%) approaches were the least common. Of 127 BLFs 78 (61.4%) were removed in their entirety and BLF length was significantly reduced to less than 4 cm in 21 (16.5%) or lead tip in 12 (9.4%) cases. The best results were achieved when BLFs were longer (>4 cm) (62/93 66.7% of longer BLFs), either in the case of BLFs free-floating in vascular bed including pulmonary circulation (68.4% of them) but not in cases of short BLFs (20.0% of short BLFs). Complete procedural success was achieved in 57.5% of procedures, the lead tip retained in the heart wall in 12 cases (9.4%) and short BLFs were found in 26.0%, whereas BLFs >4 cm were left in place in four cases (3.1%) of procedures only. There was no relationship between approach in lead remnant removal and long-term mortality. Conclusions: (1) Effectiveness of fractured lead removal is satisfactory: entire BLFs were removed in 61.4% (total procedural success-57.5%, was lower because five major complications occurred) and BLF length was significantly reduced in 26.0%. (2) Among the broken leads, leads with a long stay in the patient (16.3 years on average), passive leads (97.6%) and pacemaker leads 92.1% are significantly more common, but not ICD leads (only 7.9% of lead fractures) compared to TLE without lead fractures. (3) Broken lead removal (superior approach) using a CS access sheath as a "subclavian workstation" for continuation of dilatation with conventional tools deserves attention. (4) Lead fracture management should become an integral part of training in transvenous lead extraction.
引用
收藏
页码:1981 / 1996
页数:16
相关论文
共 50 条
  • [41] Transvenous Extraction and Removal of Pacing Leads Placed after Cardiac Transplantation
    Norton, Caleb
    Holmes, Benjamin
    Al Aboud, Asad
    Kim, Eun-Jeong
    Gonzales, Holly
    Ellis, Christopher
    John, Roy
    Crossley, George H., III
    Montgomery, Jay
    CASE REPORTS IN CARDIOLOGY, 2019, 2019
  • [42] Defense sector reform in the Western Balkans - different approaches and different tools
    Busterud, Ingrid Olstad
    EUROPEAN SECURITY, 2015, 24 (02) : 335 - 352
  • [43] Extraction of pacemaker and implantable cardioverter defibrillator leads: Patient and lead characteristics in relation to the requirement of extraction tools
    Bracke, F
    Meijer, A
    Van Gelder, B
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (07): : 1037 - 1040
  • [44] Tools for working with guidelines in different interface design approaches
    Reiterer, H
    TOOLS FOR WORKING WITH GUIDELINES, 2001, : 225 - 236
  • [45] The Effect of Lacrosse Helmet Design on Face Mask Removal with Different Removal Tools
    Bradney, Debbie
    Bowman, Thomas
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 131 - 131
  • [46] Comparison of Different Approaches to Patent Search
    Simsek, Bugra
    Demirel, Onur
    Tamkoc, Ali Kemal
    Kilinckaya, Behic
    Somuncu, Ozcan
    Sahin, Pinar Duygulu
    32ND IEEE SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU 2024, 2024,
  • [47] A Comparison of Different Approaches in BTK Revascularization
    Dinoto, Ettore
    Mirabella, Domenico
    Pecoraro, Felice
    JOURNAL OF VASCULAR SURGERY, 2024, 79 (04) : 39S - 39S
  • [48] COMPARISON OF DIFFERENT APPROACHES TO SEGREGATION ANALYSIS
    WILLIAMS, WR
    BADZIOCH, MD
    ANDERSON, DE
    AMERICAN JOURNAL OF HUMAN GENETICS, 1983, 35 (06) : A210 - A210
  • [49] Polarimetric Calibration - a comparison of different approaches
    Schimpf, Hartmut
    Fuchs, Hans-Hellmuth
    2008 PROCEEDINGS INTERNATIONAL RADAR SYMPOSIUM, 2008, : 152 - 155
  • [50] Comparison of different treatment approaches for gangliogliomas
    Rades, D.
    Zwick, L.
    Leppert, J.
    Bonsanto, M. M.
    Tronnier, V.
    Dunst, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2009, 185 : 15 - 15