Removal of leads broken during extraction: A comparison of different approaches and tools

被引:0
|
作者
Kutarski, Andrzej [1 ]
Jachec, Wojciech [2 ]
Pietura, Radoslaw [3 ]
Stefanczyk, Pawel [4 ]
Kosior, Jaroslaw [5 ]
Czakowski, Marek [6 ]
Sawonik, Sebastian [1 ]
Tulecki, Lukasz [7 ]
Nowosielecka, Dorota [4 ,7 ]
机构
[1] Med Univ Lublin, Dept Cardiol, Lublin, Poland
[2] Med Univ Silesia, Fac Med Sci Zabrze, Dept Cardiol 2, Katowice, Poland
[3] Med Univ Lublin, Dept Radiog, Lublin, Poland
[4] Pope John Paul II Prov Hosp, Dept Cardiol, Zamosc, Poland
[5] Masovian Specialist Hosp Radom, Dept Cardiol, Radom, Poland
[6] Med Univ Lublin, Med Univ, Dept Cardiac Surg, Lublin, Poland
[7] Pope John Paul II Prov Hosp, Dept Cardiac Surg, Al Jana Pawla II 10, PL-22400 Zamosc, Poland
关键词
femoral approach; incomplete lead extraction; lead fragment removal; techniques of lead fragment removal; transvenous lead extraction; EXPERT CONSENSUS STATEMENT; PACEMAKER LEAD; ELECTRODE FRAGMENT; MANAGEMENT; EMBOLIZATION; PREDICTORS; EXPERIENCE; RETRIEVAL; MIGRATION; OUTCOMES;
D O I
10.1111/jce.16398
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Extraction of a broken lead fragment (BLF) has received scant attention in the literature. Methods: Retrospective analysis was to compare the effectiveness of different approaches and tools used for BLF removal during 127 procedures. Results: A superior approach was the most popular (75.6%), femoral (15.7%) and combined (8.7%) approaches were the least common. Of 127 BLFs 78 (61.4%) were removed in their entirety and BLF length was significantly reduced to less than 4 cm in 21 (16.5%) or lead tip in 12 (9.4%) cases. The best results were achieved when BLFs were longer (>4 cm) (62/93 66.7% of longer BLFs), either in the case of BLFs free-floating in vascular bed including pulmonary circulation (68.4% of them) but not in cases of short BLFs (20.0% of short BLFs). Complete procedural success was achieved in 57.5% of procedures, the lead tip retained in the heart wall in 12 cases (9.4%) and short BLFs were found in 26.0%, whereas BLFs >4 cm were left in place in four cases (3.1%) of procedures only. There was no relationship between approach in lead remnant removal and long-term mortality. Conclusions: (1) Effectiveness of fractured lead removal is satisfactory: entire BLFs were removed in 61.4% (total procedural success-57.5%, was lower because five major complications occurred) and BLF length was significantly reduced in 26.0%. (2) Among the broken leads, leads with a long stay in the patient (16.3 years on average), passive leads (97.6%) and pacemaker leads 92.1% are significantly more common, but not ICD leads (only 7.9% of lead fractures) compared to TLE without lead fractures. (3) Broken lead removal (superior approach) using a CS access sheath as a "subclavian workstation" for continuation of dilatation with conventional tools deserves attention. (4) Lead fracture management should become an integral part of training in transvenous lead extraction.
引用
收藏
页码:1981 / 1996
页数:16
相关论文
共 50 条
  • [31] Comparison of different approaches for the simulation of topography evolution during lithography development
    Schnattinger, T. (thomas.schnattinger@iisb.fraunhofer.de), 2005, IEEE Electron Devices Society; Japan Society of Applied Physics (Institute of Electrical and Electronics Engineers Inc.):
  • [32] Running shoe properties during age: A comparison of two different approaches
    Heidenfelder J.
    Sterzing T.
    Milani T.L.
    Footwear Science, 2011, 3 (SUPPL.1) : S70 - S72
  • [33] Generative Engineering and Design - A Comparison of Different Approaches to Utilize Artificial Intelligence in CAD Software Tools
    Gerhard, Detlef
    Koring, Timo
    Neges, Matthias
    PRODUCT LIFECYCLE MANAGEMENT PLM IN TRANSITION TIMES: THE PLACE OF HUMANS AND TRANSFORMATIVE TECHNOLOGIES, PLM 2022, 2023, 667 : 206 - 215
  • [34] Comparison of topic extraction approaches and their results
    Theresa Velden
    Kevin W. Boyack
    Jochen Gläser
    Rob Koopman
    Andrea Scharnhorst
    Shenghui Wang
    Scientometrics, 2017, 111 : 1169 - 1221
  • [35] Comparison between percutaneous extraction of implantable cardioverter defibrillator leads and pacemaker leads
    Klug, D.
    Marquie, C.
    Brigadeau, F.
    Guedon, L.
    Kouakam, C.
    Lacroix, D.
    Kacet, S.
    EUROPEAN HEART JOURNAL, 2008, 29 : 397 - 397
  • [36] In Vitro Comparison of Several Thrombus Removal Tools
    Pigon, Katarzyna
    Tomecka, Natalia
    Korner, Dominika
    Pekala, Maciej
    Grzegorczyn, Slawomir
    Konka, Adam
    Nowalany-Kozielska, Ewa
    Tomasik, Andrzej
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2023, 10 (02)
  • [37] Comparison of Different Extraction Sites Used During Laparoscopic Radical Nephrectomy
    Bird, Vincent G.
    Au, Jason K.
    Sandman, Yekutiel
    Santos, Rosely De Los
    Ayyathurai, Rajnikanth
    Shields, John M.
    JOURNAL OF UROLOGY, 2009, 181 (04): : 1565 - 1570
  • [38] COMPARISON OF DIFFERENT APPROACHES TO RENORMALIZATION
    MARINARO, M
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A, 1972, A 9 (01): : 62 - +
  • [39] Nonthoracotomy implantable defibrillator lead extraction: Results and comparison with extraction of pacemaker leads
    Saad, EB
    Saliba, WI
    Schweikert, RA
    Al-Khadra, AS
    Abdul-Karim, A
    Niebauer, MJ
    Wilkoff, BL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (10): : 1944 - 1950
  • [40] Novel Technique for Removal of a Broken Intracortical Screw During THA
    Dietz, Matthew J.
    Chase, Samantha
    Burke, Dennis W.
    Kwon, Young-Min
    ORTHOPEDICS, 2013, 36 (11) : 846 - 849