MU variability in CBCT-guided online adaptive radiation therapy

被引:0
|
作者
Tanny, Sean [1 ,3 ]
Dona Lemus, Olga M. [1 ]
Wancura, Joshua [1 ]
Sperling, Nicholas [2 ]
Webster, Matthew [1 ]
Jung, Hyunuk [1 ]
Zhou, Yuwei [1 ]
Li, Fiona [1 ]
Yoon, Jihyung [1 ]
Podgorsak, Alexander [1 ]
Zheng, Dandan [1 ]
机构
[1] Univ Rochester, Med Ctr, Dept Radiat Oncol, New York, NY USA
[2] Univ Toledo, Med Ctr, Dept Radiat Oncol, Toledo, OH USA
[3] Univ Rochester, Med Ctr, Wilmot Canc Inst, 601 Elmwood Ave, Rochester, NY 14642 USA
来源
关键词
adaptive radiotherapy; CBCT-based adaptive RT; ethos-based adaptive; MU variability; patient specific QA; plan QA; APERTURE COMPLEXITY;
D O I
10.1002/acm2.14440
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeCBCT-guided online-adaptive radiotherapy (oART) systems have been made possible by using artificial intelligence and automation to substantially reduce treatment planning time during on-couch adaptive sessions. Evaluating plans generated during an adaptive session presents significant challenges to the clinical team as the planning process gets compressed into a shorter window than offline planning. We identified MU variations up to 30% difference between the adaptive plan and the reference plan in several oART sessions that caused the clinical team to question the accuracy of the oART dose calculation. We investigated the cause of MU variation and the overall accuracy of the dose delivered when MU variations appear unnecessarily large.MethodsDosimetric and adaptive plan data from 604 adaptive sessions of 19 patients undergoing CBCT-guided oART were collected. The analysis included total MU per fraction, planning target volume (PTV) and organs at risk (OAR) volumes, changes in PTV-OAR overlap, and DVH curves. Sessions with MU greater than two standard deviations from the mean were reoptimized offline, verified by an independent calculation system, and measured using a detector array.ResultsMU variations relative to the reference plan were normally distributed with a mean of -1.0% and a standard deviation of 11.0%. No significant correlation was found between MU variation and anatomic changes. Offline reoptimization did not reliably reproduce either reference or on-couch total MUs, suggesting that stochastic effects within the oART optimizer are likely causing the variations. Independent dose calculation and detector array measurements resulted in acceptable agreement with the planned dose.ConclusionsMU variations observed between oART plans were not caused by any errors within the oART workflow. Providers should refrain from using MU variability as a way to express their confidence in the treatment planning accuracy. Clinical decisions during on-couch adaptive sessions should rely on validated secondary dose calculations to ensure optimal plan selection.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Synthetic CT-aided Online CBCT Multi-Organ Segmentation for CBCT-guided Adaptive Radiotherapy of Pancreatic Cancer
    Janopaul-Naylor, J.
    Lei, Y.
    Liu, Y.
    Wang, T.
    Curran, W. J., Jr.
    Liu, T.
    Patel, P. R.
    Yang, X.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 108 (03): : S7 - S8
  • [32] Clinical implementation of RTT-only CBCT-guided online adaptive focal radiotherapy for bladder cancer
    Goudschaal, K.
    Azzarouali, S.
    Visser, J.
    Admiraal, M.
    Wiersma, J.
    van Wieringen, N.
    de la Fuente, A.
    Piet, M.
    Daniels, L.
    den Boer, D.
    Hulshof, M.
    Bel, A.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2025, 50
  • [33] CBCT-guided online adaptive radiotherapy in breast cancer patients - a prospective trial NL2021.0624
    van Vlaenderen, Angelique R. W.
    Nelissen, Koen J.
    Middelburg-van Rijn, Judith G.
    Rijksen, Barbara L. T.
    Visser, Jorrit
    Admiraal, Marjan
    Goudschaal, Karin N.
    Bucko, Ewa
    Glebbeek, Cassey E.
    Bijker, Nina
    Slotman, Ben
    Verbakel, Wilko F. A. R.
    van den Bongard, Desiree H. J. G.
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S469 - S473
  • [34] Feasibility evaluation of RTT-only CBCT-guided daily online adaptive radiotherapy for prostate tumor
    Caricato, Paolo
    Sapignoli, Sonia
    Sepulcri, Matteo
    Cipriano, Sara
    Surey, Ashlyng Esthefany Rivas
    Bettinelli, Andrea
    Guida, Federica
    Rossato, Marco Andrea
    Krengli, Marco
    Paiusco, Marta
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S5850 - S5851
  • [35] Developing training for RTT-led CBCT-guided daily online adaptive radiotherapy for urological cancer
    Graham, S.
    Daly, K.
    Ward, A.
    Martinou, M.
    Withers, D.
    Kidane, G.
    Almond, E.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S601 - S602
  • [36] A Computational Framework for Patient-Specific Dose Agreement Verification in CBCT-Guided Radiation Therapy
    Xia, R.
    Zhang, R.
    Yang, M.
    Guo, F.
    Tang, M.
    Zhou, L.
    Liu, M.
    Yin, F. F.
    Chen, M.
    Yang, Z.
    MEDICAL PHYSICS, 2024, 51 (10) : 7724 - 7725
  • [37] On the trail of CBCT-guided adaptive rectal boost radiotherapy, does daily delineation require a radiation oncologist?
    Pierrard, Julien
    Dechambre, David
    Massih, Christel Abdel
    Cvilic, Sophie
    Roma, Ana Da Silva Chambel
    Henderickx, Pascale
    Heylen, Sofie
    Longton, Eleonore
    Mony, Romain
    Tenabene, Mohamed Amine
    Tison, Thais
    Vandermeulen, Ad
    Vander Veken, Loic
    Etume, Aniko Wale
    Yeo, Anne-Emmanuella
    Van Ooteghem, Genevieve
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 32
  • [38] Kilo-Voltage Imaging Doses to Organs-at-Risk in CBCT-guided Breast Radiation Therapy
    Deng, J.
    Chen, Z.
    Knisely, J.
    Nath, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S233 - S234
  • [39] AI-based online adaptive CBCT-guided radiotherapy for bladder cancer using SIB and fiducial markers
    Azzarouali, S.
    Goudschaal, K.
    den Boer, D.
    Visser, J.
    Hulshof, M.
    Bel, A.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S196 - S197
  • [40] Stopping Power Map Estimation From Cone-Beam CT Using Deep Learning for CBCT-Guided Adaptive Radiation Therapy
    Harms, J.
    Lei, Y.
    Wang, T.
    Ghavidel, B.
    Stokes, W.
    Liu, T.
    Curran, W.
    Zhou, J.
    McDonald, M.
    Yang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E476 - E476