Comparison of Wireless Continuous Axillary and Core Temperature Measurement after Major Surgery

被引:0
|
作者
Nathansen, Anders Blom [1 ]
Molgaard, Jesper [1 ]
Meyhoff, Christian Sylvest [2 ,3 ]
Aasvang, Eske Kvanner [1 ,3 ]
机构
[1] Univ Copenhagen, Ctr Canc & Organ Dis, Dept Anesthesiol, Rigshosp, Blegdamsvej 9, DK-2200 Copenhagen, Denmark
[2] Univ Copenhagen, Bispebjerg Hosp, Dept Anesthesia & Intens Care, DK-2400 Copenhagen, Denmark
[3] Univ Copenhagen, Dept Clin Med, DK-2200 Copenhagen, Denmark
关键词
vital signs; fever; temperature; wireless monitoring; axillary; validation; INFECTION; OUTCOMES;
D O I
10.3390/s24144469
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Temperature is considered one of the primary vital signs for detection of complications such as infections. Continuous wireless real-time axillary temperature monitoring is technologically feasible at the general ward, but no clinical validation studies exist. Methods: This study compared axillary temperature with a urinary bladder thermometer in 40 major abdominal postoperative patients. The primary outcome was changes in axillary temperature registrations. Secondary outcomes were mean bias between the urinary bladder and the axillary temperatures. Intermittent frontal and tympanic temperature recordings were also collected. Results: Forty patients were monitored for 50 min with an average core temperature of 36.8 degrees C. The mean bias was -1.0 degrees C (LoA -1.9 to -0) after 5 min, and -0.8 degrees C (LoA -1.6 to -0.1) after 10 min when comparing the axillary temperature with the urinary bladder temperature. After 20 min, the mean bias was -0.6 degrees C (LoA -1.3-0.1). During upper arm abduction, the axilla temperature was reduced to -1.6 degrees C (LoA -2.9 to -0.3) within 1 min. Temporal skin temperature measurement had a resulted in a mean bias of -0.1 degrees C (LOA -1.1 to -1.0) compared with central temperature. Compared with the mean tympanic temperature, it was -0.1 degrees C (LoA -0.9 to -1.0) lower than the urinay bladder temperature. Conclusions: Axillary temperature increased with time, reaching a mean bias of 1 degrees C between axillary and core temperature within 5 min. Opening the axillary resulted in rapidly lower temperature recordings. These findings may aid in use and designing corrections for continuous axillary temperature monitoring.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Disturbed core body temperature rhythm after major surgery
    Gögenur I.
    Eversbusch A.
    Achiam M.
    Sølving P.
    Rosenberg J.
    Sleep and Biological Rhythms, 2004, 2 (3) : 226 - 228
  • [2] Agreement between standard and continuous wireless vital sign measurements after major abdominal surgery: a clinical comparison study
    Haahr-Raunkjaer, Camilla
    Skovbye, Magnus
    Rasmussen, Soren M.
    Elvekjaer, Mikkel
    Sorensen, Helge B. D.
    Meyhoff, Christian S.
    Aasvang, Eske K.
    PHYSIOLOGICAL MEASUREMENT, 2022, 43 (11)
  • [3] COMPARISON OF EAR-BASED, BLADDER, ORAL, AND AXILLARY METHODS FOR CORE TEMPERATURE-MEASUREMENT
    ERICKSON, RS
    KIRKLIN, SK
    CRITICAL CARE MEDICINE, 1993, 21 (10) : 1528 - 1534
  • [4] Temperature measurements of a wearable and wireless axillary sensor iThermonitor but not a bladder probe represents the core temperature during laparoscopic rectal surgery
    Dai, Yanran
    Luo, Mengjia
    Liu, Feifei
    Feng, Xiangying
    Nie, Huang
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2023, 37 (01) : 303 - 309
  • [5] Temperature measurements of a wearable and wireless axillary sensor iThermonitor but not a bladder probe represents the core temperature during laparoscopic rectal surgery
    Yanran Dai
    Mengjia Luo
    Feifei Liu
    Xiangying Feng
    Huang Nie
    Journal of Clinical Monitoring and Computing, 2023, 37 : 303 - 309
  • [6] Disturbances in melatonin, cortisol and core body temperature rhythms after major surgery
    Gogenur, Ismail
    Ocak, Ubbat
    Altunpinar, Omer
    Middleton, Benita
    Skene, Debra J.
    Rosenberg, Jacob
    WORLD JOURNAL OF SURGERY, 2007, 31 (02) : 290 - 298
  • [7] Disturbances in Melatonin, Cortisol and Core Body Temperature Rhythms after Major Surgery
    Ismail Gögenur
    Ubbat Ocak
    Ömer Altunpinar
    Benita Middleton
    Debra J. Skene
    Jacob Rosenberg
    World Journal of Surgery, 2007, 31 : 290 - 298
  • [8] The Accuracy of a Wireless Axillary Thermometer for Core Temperature Monitoring in Pediatric Patients Having Noncardiac Surgery: An Observational Study
    Ji, Yingtong
    Han, Ding
    Han, Lu
    Xie, Siyuan
    Pan, Shoudong
    JOURNAL OF PERIANESTHESIA NURSING, 2021, 36 (06) : 685 - 689
  • [9] Wireless System for Continuous Monitoring of Core Body Temperature
    Haines, Will
    Momenroodaki, Parisa
    Berry, Eric
    Fromandi, Michael
    Popovic, Zoya
    2017 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM (IMS), 2017, : 537 - 539
  • [10] Comparison of axillary, tympanic membrane and rectal temperature measurement in cats
    Smith, Victoria A.
    Lamb, Valerie
    McBrearty, Alix R.
    JOURNAL OF FELINE MEDICINE AND SURGERY, 2015, 17 (12) : 1028 - 1034