Comparison of Wireless Continuous Axillary and Core Temperature Measurement after Major Surgery

被引:0
|
作者
Nathansen, Anders Blom [1 ]
Molgaard, Jesper [1 ]
Meyhoff, Christian Sylvest [2 ,3 ]
Aasvang, Eske Kvanner [1 ,3 ]
机构
[1] Univ Copenhagen, Ctr Canc & Organ Dis, Dept Anesthesiol, Rigshosp, Blegdamsvej 9, DK-2200 Copenhagen, Denmark
[2] Univ Copenhagen, Bispebjerg Hosp, Dept Anesthesia & Intens Care, DK-2400 Copenhagen, Denmark
[3] Univ Copenhagen, Dept Clin Med, DK-2200 Copenhagen, Denmark
关键词
vital signs; fever; temperature; wireless monitoring; axillary; validation; INFECTION; OUTCOMES;
D O I
10.3390/s24144469
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Temperature is considered one of the primary vital signs for detection of complications such as infections. Continuous wireless real-time axillary temperature monitoring is technologically feasible at the general ward, but no clinical validation studies exist. Methods: This study compared axillary temperature with a urinary bladder thermometer in 40 major abdominal postoperative patients. The primary outcome was changes in axillary temperature registrations. Secondary outcomes were mean bias between the urinary bladder and the axillary temperatures. Intermittent frontal and tympanic temperature recordings were also collected. Results: Forty patients were monitored for 50 min with an average core temperature of 36.8 degrees C. The mean bias was -1.0 degrees C (LoA -1.9 to -0) after 5 min, and -0.8 degrees C (LoA -1.6 to -0.1) after 10 min when comparing the axillary temperature with the urinary bladder temperature. After 20 min, the mean bias was -0.6 degrees C (LoA -1.3-0.1). During upper arm abduction, the axilla temperature was reduced to -1.6 degrees C (LoA -2.9 to -0.3) within 1 min. Temporal skin temperature measurement had a resulted in a mean bias of -0.1 degrees C (LOA -1.1 to -1.0) compared with central temperature. Compared with the mean tympanic temperature, it was -0.1 degrees C (LoA -0.9 to -1.0) lower than the urinay bladder temperature. Conclusions: Axillary temperature increased with time, reaching a mean bias of 1 degrees C between axillary and core temperature within 5 min. Opening the axillary resulted in rapidly lower temperature recordings. These findings may aid in use and designing corrections for continuous axillary temperature monitoring.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] COMPARISON OF KETOROLAC AND MORPHINE FOR POSTOPERATIVE PAIN AFTER MAJOR SURGERY
    STOUTEN, EM
    ARMBRUSTER, S
    HOUMES, RJ
    PRAKASH, O
    ERDMANN, W
    LACHMANN, B
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1992, 36 (07) : 716 - 721
  • [42] Wireless, multimodal sensors for continuous measurement of pressure, temperature, and hydration of patients in wheelchair
    Seokjoo Cho
    Hyeonseok Han
    Hyunwoo Park
    Sung-Uk Lee
    Jae-Hwan Kim
    Sung Woo Jeon
    Mengqiu Wang
    Raudel Avila
    Zhaoqian Xi
    Kabseok Ko
    Minsu Park
    Jungyup Lee
    Myungwoo Choi
    Je-Sang Lee
    Weon Gi Min
    Byeong-Ju Lee
    Soyeong Lee
    Jungrak Choi
    Jimin Gu
    Jaeho Park
    Min Seong Kim
    Junseong Ahn
    Osman Gul
    Chankyu Han
    Gihun Lee
    Seunghwan Kim
    Kyuyoung Kim
    Jeonghyun Kim
    Chang-Mo Kang
    Jahyun Koo
    Sung Soo Kwak
    Sungbong Kim
    Dong Yun Choi
    Seokwoo Jeon
    Hyung Jin Sung
    Yong Bae Park
    Minkyu Je
    Young Tae Cho
    Yong Suk Oh
    Inkyu Park
    npj Flexible Electronics, 7
  • [43] A NONINVASIVE TRANSCUTANEOUS ALTERNATIVE TO RECTAL THERMOMETRY FOR CONTINUOUS MEASUREMENT OF CORE TEMPERATURE IN THE PIGLET
    DOLLBERG, S
    XI, YR
    DONNELLY, MM
    PEDIATRIC RESEARCH, 1993, 34 (04) : 512 - 517
  • [44] Non-invasive continuous core temperature measurement by zero heat flux
    Teunissen, L. P. J.
    Klewer, J.
    de Haan, A.
    de Koning, J. J.
    Daanen, H. A. M.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (05) : 559 - 570
  • [45] ACTIVITY DISK AND CAGE FOR CONTINUOUS MEASUREMENT OF RUNNING ACTIVITY AND CORE TEMPERATURE IN HAMSTERS
    BORER, KT
    DENNIS, R
    PHYSIOLOGY & BEHAVIOR, 1991, 50 (05) : 1057 - 1061
  • [46] A TRANSCUTANEOUS ALTERNATIVE TO RECTAL THERMOMETRY FOR CONTINUOUS MEASUREMENT OF CORE TEMPERATURE IN PRETERM INFANTS
    DOLLBERG, S
    ATHERTON, HD
    ALLEN, K
    HOATH, SB
    PEDIATRIC RESEARCH, 1994, 35 (04) : A222 - A222
  • [47] COMPARISON OF THE EFFECTS OF CONTINUOUS AND DISCONTINUOUS NASOGASTRIC FEEDING ON METABOLIC-RATE AND NITROGEN-BALANCE AFTER MAJOR SURGERY
    CAMPBELL, IT
    MORTON, RP
    COLE, JA
    RAINE, CH
    SHAPIRO, LM
    STELL, PM
    BRITISH JOURNAL OF ANAESTHESIA, 1983, 55 (11) : 1160 - 1160
  • [48] Routine use of continuous positive airway pressure after major abdominal surgery
    Hess, Dean R.
    Branson, Richard D.
    LANCET RESPIRATORY MEDICINE, 2021, 9 (11): : 1204 - 1205
  • [49] Continuous interscalene brachial plexus block at home after major shoulder surgery
    Nielsen, KC
    Steele, SM
    Klein, SM
    Pietrobon, RS
    Greengrass, RA
    ANESTHESIOLOGY, 2000, 93 (3A) : U124 - U124
  • [50] Combined continuous popliteal and femoral nerve block after major ankle surgery
    Blumenthal, S.
    Aguirre, J.
    Marquardt, M.
    Vienne, P.
    Borgeat, A.
    SWISS MEDICAL WEEKLY, 2007, 137 : 17S - 17S