Comparison of Wireless Continuous Axillary and Core Temperature Measurement after Major Surgery

被引:0
|
作者
Nathansen, Anders Blom [1 ]
Molgaard, Jesper [1 ]
Meyhoff, Christian Sylvest [2 ,3 ]
Aasvang, Eske Kvanner [1 ,3 ]
机构
[1] Univ Copenhagen, Ctr Canc & Organ Dis, Dept Anesthesiol, Rigshosp, Blegdamsvej 9, DK-2200 Copenhagen, Denmark
[2] Univ Copenhagen, Bispebjerg Hosp, Dept Anesthesia & Intens Care, DK-2400 Copenhagen, Denmark
[3] Univ Copenhagen, Dept Clin Med, DK-2200 Copenhagen, Denmark
关键词
vital signs; fever; temperature; wireless monitoring; axillary; validation; INFECTION; OUTCOMES;
D O I
10.3390/s24144469
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: Temperature is considered one of the primary vital signs for detection of complications such as infections. Continuous wireless real-time axillary temperature monitoring is technologically feasible at the general ward, but no clinical validation studies exist. Methods: This study compared axillary temperature with a urinary bladder thermometer in 40 major abdominal postoperative patients. The primary outcome was changes in axillary temperature registrations. Secondary outcomes were mean bias between the urinary bladder and the axillary temperatures. Intermittent frontal and tympanic temperature recordings were also collected. Results: Forty patients were monitored for 50 min with an average core temperature of 36.8 degrees C. The mean bias was -1.0 degrees C (LoA -1.9 to -0) after 5 min, and -0.8 degrees C (LoA -1.6 to -0.1) after 10 min when comparing the axillary temperature with the urinary bladder temperature. After 20 min, the mean bias was -0.6 degrees C (LoA -1.3-0.1). During upper arm abduction, the axilla temperature was reduced to -1.6 degrees C (LoA -2.9 to -0.3) within 1 min. Temporal skin temperature measurement had a resulted in a mean bias of -0.1 degrees C (LOA -1.1 to -1.0) compared with central temperature. Compared with the mean tympanic temperature, it was -0.1 degrees C (LoA -0.9 to -1.0) lower than the urinay bladder temperature. Conclusions: Axillary temperature increased with time, reaching a mean bias of 1 degrees C between axillary and core temperature within 5 min. Opening the axillary resulted in rapidly lower temperature recordings. These findings may aid in use and designing corrections for continuous axillary temperature monitoring.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] A comparison of core and tympanic temperature measurement in the critically ill
    B Sanderson
    L Lim
    K Lei
    J Smith
    L Camporota
    R Beale
    Critical Care, 14 (Suppl 1):
  • [22] Temple Touch Pro continuous temperature measurement comparison with invasive temperature measurement techniques
    Sherman, A.
    Toives, V
    Ezri, T.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 36 - 36
  • [23] COMPARISON OF TEMPERATURE MEASUREMENT IN THE BLADDER, RECTUM AND PULMONARY ARTERY IN PATIENTS AFTER CARDIAC SURGERY
    Wollerich, H.
    Nijsten, M. W.
    Ismael, F.
    INTENSIVE CARE MEDICINE, 2010, 36 : S307 - S307
  • [24] COMPARISON OF BLADDER, ESOPHAGEAL AND PULMONARY-ARTERY TEMPERATURE-MEASUREMENT IN MAJOR ABDOMINAL-SURGERY
    RUSSELL, SH
    FREEMAN, JW
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 : 16 - 16
  • [25] Comparison of temporal artery, nasopharyngeal, and axillary temperature measurement during anesthesia in children
    Sahin, Sevtap Hekimoglu
    Duran, Ridvan
    Sut, Necdet
    Colak, Alkin
    Acunas, Betul
    Aksu, Burhan
    JOURNAL OF CLINICAL ANESTHESIA, 2012, 24 (08) : 647 - 651
  • [26] Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery
    Hao Liang
    Jing-Yan Wang
    Yan Liang
    Xin-Feng Shao
    Yan-Ling Ding
    Hui-Qun Jia
    Journal of Clinical Monitoring and Computing, 2024, 38 : 197 - 203
  • [27] Agreement of zero-heat-flux thermometry with the oesophageal and tympanic core temperature measurement in patient receiving major surgery
    Liang, Hao
    Wang, Jing-Yan
    Liang, Yan
    Shao, Xin-Feng
    Ding, Yan-Ling
    Jia, Hui-Qun
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2024, 38 (01) : 197 - 203
  • [28] Placement of temperature probe in bovine vagina for continuous measurement of core-body temperature
    C. N. Lee
    K. G. Gebremedhin
    A. Parkhurst
    P. E. Hillman
    International Journal of Biometeorology, 2015, 59 : 1201 - 1205
  • [29] Placement of temperature probe in bovine vagina for continuous measurement of core-body temperature
    Lee, C. N.
    Gebremedhin, K. G.
    Parkhurst, A.
    Hillman, P. E.
    INTERNATIONAL JOURNAL OF BIOMETEOROLOGY, 2015, 59 (09) : 1201 - 1205
  • [30] Comparison of continuous versus patient-controlled epidural analgesia with 0.2% ropivacaine after major abdominal surgery
    Standl, T
    Wilhelm, S
    Burmeister, MA
    Fuellekrug, B
    Hern, EP
    ANESTHESIOLOGY, 1999, 91 (3A) : U395 - U395