Temperature measurements of a wearable and wireless axillary sensor iThermonitor but not a bladder probe represents the core temperature during laparoscopic rectal surgery

被引:2
|
作者
Dai, Yanran [1 ]
Luo, Mengjia [1 ]
Liu, Feifei [1 ]
Feng, Xiangying [1 ]
Nie, Huang [2 ]
机构
[1] Air Force Med Univ, Xijing Hosp, Dept Gastrointestinal Surg, Xian, Peoples R China
[2] Air Force Med Univ, Xijing Hosp, Dept Anaesthesiol, Xian, Peoples R China
关键词
Core temperature; iThermonitor; Laparoscopic rectal surgery; CONCORDANCE CORRELATION-COEFFICIENT; BODY-TEMPERATURE; HYPOTHERMIA; NORMOTHERMIA; HYPERTHERMIA; REDUCE;
D O I
10.1007/s10877-022-00892-4
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective To investigate whether the temperature recorded by an iThermonitor has better concordance with the core temperature than the bladder temperature recorded by a Foley catheter sensor in laparoscopic rectal surgery. Methods Eighty-two adults undergoing laparoscopic rectal surgery were enrolled. Temperatures were continuously measured by a distal oesophageal probe (the reference core temperature), axillary iThermonitor and Foley catheter sensor (bladder temperature) in each patient during surgery. Pairs of axillary and core temperatures or pairs of bladder temperature and core temperatures were compared and summarized using linear regression and the repeated-measured Bland-Altman method during the whole surgical period and pneumoperitoneum period. Results There were 3303 pairs of temperature measurements during the whole surgical period. The mean difference between iThermonitor and oesophageal was 0.05 degrees C ; the limits of agreement were - 0.48 to 0.56 degrees C. The mean difference between the oesophagus and bladder was 0.28 degrees C; the limits of agreement were - 0.39 to 0.94 degrees C (P < 0.001, F-test vs. iThermonitor). Ninety -five% of all iThermonitor values were within 0.5 degrees C of oesophageal temperature, whereas the proportion for oesophageal and bladder differences within 0.5 degrees C was only 84% (95% confidence interval 80-88%). Lin's CCC for the iThermonitor and bladder measurements were 0.842 (95%CI: 0.831-0.851) and 0.688 (95%CI: 0.673-0.703) respectively. Similar results were found during the pneumoperitoneum period. Conclusions The temperature recorded by iThermonitor has better concordance with the core temperature than the bladder temperature recorded by Foley catheter sensor in laparoscopic rectal surgery.
引用
收藏
页码:303 / 309
页数:7
相关论文
共 22 条
  • [1] Temperature measurements of a wearable and wireless axillary sensor iThermonitor but not a bladder probe represents the core temperature during laparoscopic rectal surgery
    Yanran Dai
    Mengjia Luo
    Feifei Liu
    Xiangying Feng
    Huang Nie
    Journal of Clinical Monitoring and Computing, 2023, 37 : 303 - 309
  • [2] Axillary Temperature, as Recorded by the iThermonitor WT701, Well Represents Core Temperature in Adults Having Noncardiac Surgery
    Pei, Lijian
    Huang, Yuguang
    Mao, Guangmei
    Sessler, Daniel I.
    ANESTHESIA AND ANALGESIA, 2018, 126 (03): : 833 - 838
  • [3] Wearable Wireless Sensor for Estrus Detection in Cows by Conductivity and Temperature Measurements
    Andersson, L. Mattias
    Okada, Hironao
    Zhang, Yi
    Itoh, Toshihiro
    Miura, Ryotaro
    Yoshioka, Koji
    2015 IEEE SENSORS, 2015, : 225 - 228
  • [4] Comparison of Wireless Continuous Axillary and Core Temperature Measurement after Major Surgery
    Nathansen, Anders Blom
    Molgaard, Jesper
    Meyhoff, Christian Sylvest
    Aasvang, Eske Kvanner
    SENSORS, 2024, 24 (14)
  • [5] Core temperature changes during open and laparoscopic colorectal surgery
    Luck, AJ
    Moyes, D
    Maddern, GJ
    Hewett, PJ
    SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (05): : 480 - 483
  • [6] Core temperature changes during open and laparoscopic colorectal surgery
    A. J. Luck
    D. Moyes
    G. J. Maddern
    P. J. Hewett
    Surgical Endoscopy, 1999, 13 : 480 - 483
  • [7] MONITORING CORE TEMPERATURE DURING EXERCISE - INGESTIBLE SENSOR VS RECTAL THERMISTOR
    SPARLING, PB
    SNOW, TK
    MILLARDSTAFFORD, ML
    AVIATION SPACE AND ENVIRONMENTAL MEDICINE, 1993, 64 (08): : 760 - 763
  • [8] Measurement of core temperature during postoperative rewarming; a comparison of oesophageal, bladder, and rectal temperatures
    Brauer, A
    Weyland, W
    Fritz, U
    Schuhmann, MU
    Schmidt, JH
    Braun, U
    ANAESTHESIST, 1997, 46 (08): : 683 - 688
  • [9] The Accuracy of a Wireless Axillary Thermometer for Core Temperature Monitoring in Pediatric Patients Having Noncardiac Surgery: An Observational Study
    Ji, Yingtong
    Han, Ding
    Han, Lu
    Xie, Siyuan
    Pan, Shoudong
    JOURNAL OF PERIANESTHESIA NURSING, 2021, 36 (06) : 685 - 689
  • [10] Visceral fat, but not subcutaneous fat, is associated with lower core temperature during laparoscopic surgery
    Miyazaki, Ryohei
    Hoka, Sumio
    Yamaura, Ken
    PLOS ONE, 2019, 14 (06):