Comparative analysis of tear film stability Automated non-invasive and fluorescein tear break-up time

被引:0
|
作者
Zeri, F. [1 ,2 ,3 ]
Rizzo, G. C. [1 ,2 ]
Ponzini, E. [1 ,2 ]
Borghesi, A. [1 ,2 ]
Tavazzi, S. [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dipartimento Sci Mat, Milan, Italy
[2] Univ Milano Bicocca, Opt & Optometry Res Ctr, COMiB, Milan, Italy
[3] Aston Univ, Coll Hlth & Life Sci, Birmingham, England
关键词
D O I
10.1393/ncc/i2024-24336-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The tear film plays a crucial role in maintaining ocular surface physiology, with tear film stability being a key parameter. Tear break-up time (TBUT) is a common method for assessing tear film stability, involving the duration between a full blink and the initial disruption in the tear film. This study aimed to assess non-invasive break-up time (NIBUT) using an automatic approach and compare it with the traditional fluorescein break-up time (fBUT) method. Forty-three non- contact lens wearers were enrolled, and NIBUT data were collected using the Sirius+ instrument. fBUT was conducted using fluorescein sodium strips. Test-retest measurements were performed with 2 hours delay. NIBUT values were consistently longer than fBUT values (14.8 +/- 8.0 s vs. 8.7 +/- 5.2 s), aligning with existing literature. The results revealed good test-retest reliability for both methods; however, intraobserver repeatability was weak. A potential limitation was the non-randomized sequence of measurements, with fBUT consistently performed at the end due to its invasive nature. Variations in the coverage area of fBUT and NIBUT assessments, influenced by factors like the Placido disc dimension, and the lash shadows, may have contributed to shorter times with fBUT. Preliminary analyses focusing only on the corneal area covered by Sirius+ Placido rings supported this hypothesis. In summary, while NIBUT consistently showed longer values than fBUT, further investigations considering limitations and potential influencing factors are warranted for a comprehensive understanding of tear film stability assessment.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] A novel method of evaluating the non-invasive tear film break-up time and progression of corneal opacification in dogs using imaging video
    Lee, Suk Jun
    Han, Myeong Gyun
    Yang, Su-Jung
    Choi, Yun-Soo
    Kim, Joon Young
    FRONTIERS IN VETERINARY SCIENCE, 2024, 11
  • [42] AGE, GENDER, AND TEAR BREAK-UP TIME
    CHO, P
    YAP, M
    OPTOMETRY AND VISION SCIENCE, 1993, 70 (10) : 828 - 831
  • [43] Effect of Loose Masks on Tear-film Break-up Time
    Lee, Jooheon
    Ahn, Minwon
    Choi, Jaewon
    Park, Minji
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2023, 64 (05): : 367 - 373
  • [44] TEAR FILM BREAK-UP TIME IN CONTACT-LENS WEARERS
    BHATIA, RPS
    SINGH, RK
    ANNALS OF OPHTHALMOLOGY, 1993, 25 (09): : 334 - 338
  • [45] SCHIRMER TEST AND BREAK-UP TIME OF TEAR FILM IN NORMAL SUBJECTS
    SHAPIRO, A
    MERIN, S
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1979, 88 (04) : 752 - 757
  • [46] Tear Film Flows Over the Whole Ocular Surface and in Tear Break-up
    Braun, Richard J.
    Li, Longfei
    Gewecke, Nicholas
    Begley, Carolyn G.
    King-Smith, Peter Ewen
    Siddique, Javed
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [47] THE INFLUENCE OF A CUTOFFS FILTER ON THE TEAR-FILM BREAK-UP TIME
    STODTMEISTER, R
    CHRIST, T
    GAUS, W
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1984, 184 (02) : 121 - 124
  • [48] Handheld Tear Film Lipid Layer Thickness and Non Invasive Tear Break Up Time Assessment Tool
    Petricek, Igor
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [49] MORPHOLOGICAL ASPECTS OF PRECORNEAL TEAR FILM BREAK-UP
    MERTZ, M
    KROBOTH, K
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1988, 193 (02) : 219 - 219
  • [50] Automatic assessment of tear film break-up dynamics
    Ramos, L.
    Barreira, N.
    Pena-Verdeal, H.
    Giraldez, M. J.
    INNOVATION IN MEDICINE AND HEALTHCARE 2014, 2014, 207 : 173 - 182