Comparative analysis of tear film stability Automated non-invasive and fluorescein tear break-up time

被引:0
|
作者
Zeri, F. [1 ,2 ,3 ]
Rizzo, G. C. [1 ,2 ]
Ponzini, E. [1 ,2 ]
Borghesi, A. [1 ,2 ]
Tavazzi, S. [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dipartimento Sci Mat, Milan, Italy
[2] Univ Milano Bicocca, Opt & Optometry Res Ctr, COMiB, Milan, Italy
[3] Aston Univ, Coll Hlth & Life Sci, Birmingham, England
关键词
D O I
10.1393/ncc/i2024-24336-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The tear film plays a crucial role in maintaining ocular surface physiology, with tear film stability being a key parameter. Tear break-up time (TBUT) is a common method for assessing tear film stability, involving the duration between a full blink and the initial disruption in the tear film. This study aimed to assess non-invasive break-up time (NIBUT) using an automatic approach and compare it with the traditional fluorescein break-up time (fBUT) method. Forty-three non- contact lens wearers were enrolled, and NIBUT data were collected using the Sirius+ instrument. fBUT was conducted using fluorescein sodium strips. Test-retest measurements were performed with 2 hours delay. NIBUT values were consistently longer than fBUT values (14.8 +/- 8.0 s vs. 8.7 +/- 5.2 s), aligning with existing literature. The results revealed good test-retest reliability for both methods; however, intraobserver repeatability was weak. A potential limitation was the non-randomized sequence of measurements, with fBUT consistently performed at the end due to its invasive nature. Variations in the coverage area of fBUT and NIBUT assessments, influenced by factors like the Placido disc dimension, and the lash shadows, may have contributed to shorter times with fBUT. Preliminary analyses focusing only on the corneal area covered by Sirius+ Placido rings supported this hypothesis. In summary, while NIBUT consistently showed longer values than fBUT, further investigations considering limitations and potential influencing factors are warranted for a comprehensive understanding of tear film stability assessment.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] RELIABILITY OF THE TEAR BREAK-UP TIME TECHNIQUE OF ASSESSING TEAR STABILITY AND THE LOCATIONS OF THE TEAR BREAK-UP IN HONG-KONG CHINESE
    CHO, P
    BROWN, B
    CHAN, I
    CONWAY, R
    YAP, M
    OPTOMETRY AND VISION SCIENCE, 1992, 69 (11) : 879 - 885
  • [22] Tear break-up time for tear film evaluation: Are moistening solutions interchangeable?
    Seres, Carme
    Quevedo, Lluisa
    Cardona, Genis
    Blanch, Estella
    Auge, Montserrat
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (04): : 272 - 276
  • [23] Evaluation of tear film interference patterns and measures of tear break-up time
    Nichols, JJ
    Nichols, KK
    Puent, B
    Saracino, M
    Mitchell, GL
    OPTOMETRY AND VISION SCIENCE, 2002, 79 (06) : 363 - 369
  • [24] Effects of wearing swimming goggles on non-invasive tear break-up time in a laboratory setting
    Vera, Jesus
    Redondo, Beatriz
    Molina, Ruben
    Jimenez, Raimundo
    JOURNAL OF OPTOMETRY, 2022, 15 (02) : 154 - 159
  • [25] Face Mask and Tear Film Stability: A Pilot Study of the Objective Measurement of Tear Break-Up Time
    Mohamed-Noriega, Karim
    Charles-Cantu, David E.
    Mohamed-Noriega, Jibran
    Velasco-Sepulveda, Braulio H.
    Morales-Wong, Fernando
    Villarreal-Mendez, Gerardo
    Mohamed-Hamsho, Jesus
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (24)
  • [26] A new modified fluorescein strip: Its repeatability and usefulness in tear film break-up time analysis
    Pult, H.
    Riede-Pult, B. H.
    CONTACT LENS & ANTERIOR EYE, 2012, 35 (01): : 35 - 38
  • [27] Tear film stability in dry eye syndrome: Time and break-up patterns
    Gallo, Vanessa
    D'Ancona, Fabrizio
    Panzeri, Alessia
    Nucci, Paolo
    Villani, Edoardo
    ACTA OPHTHALMOLOGICA, 2022, 100
  • [28] THE RELATION BETWEEN INVASIVE AND NONINVASIVE TEAR BREAK-UP TIME
    CHO, P
    DOUTHWAITE, W
    OPTOMETRY AND VISION SCIENCE, 1995, 72 (01) : 17 - 22
  • [29] Relation between invasive and noninvasive tear break-up time
    Cho, Pauline
    Douthwaite, William
    Optometry and Vision Science, 1995, 72 (01):
  • [30] NONINVASIVE TEAR FILM BREAK-UP TIME - SENSITIVITY AND SPECIFICITY
    MENGHER, LS
    PANDHER, KS
    BRON, AJ
    ACTA OPHTHALMOLOGICA, 1986, 64 (04): : 441 - 444