Comparative analysis of tear film stability Automated non-invasive and fluorescein tear break-up time

被引:0
|
作者
Zeri, F. [1 ,2 ,3 ]
Rizzo, G. C. [1 ,2 ]
Ponzini, E. [1 ,2 ]
Borghesi, A. [1 ,2 ]
Tavazzi, S. [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dipartimento Sci Mat, Milan, Italy
[2] Univ Milano Bicocca, Opt & Optometry Res Ctr, COMiB, Milan, Italy
[3] Aston Univ, Coll Hlth & Life Sci, Birmingham, England
关键词
D O I
10.1393/ncc/i2024-24336-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The tear film plays a crucial role in maintaining ocular surface physiology, with tear film stability being a key parameter. Tear break-up time (TBUT) is a common method for assessing tear film stability, involving the duration between a full blink and the initial disruption in the tear film. This study aimed to assess non-invasive break-up time (NIBUT) using an automatic approach and compare it with the traditional fluorescein break-up time (fBUT) method. Forty-three non- contact lens wearers were enrolled, and NIBUT data were collected using the Sirius+ instrument. fBUT was conducted using fluorescein sodium strips. Test-retest measurements were performed with 2 hours delay. NIBUT values were consistently longer than fBUT values (14.8 +/- 8.0 s vs. 8.7 +/- 5.2 s), aligning with existing literature. The results revealed good test-retest reliability for both methods; however, intraobserver repeatability was weak. A potential limitation was the non-randomized sequence of measurements, with fBUT consistently performed at the end due to its invasive nature. Variations in the coverage area of fBUT and NIBUT assessments, influenced by factors like the Placido disc dimension, and the lash shadows, may have contributed to shorter times with fBUT. Preliminary analyses focusing only on the corneal area covered by Sirius+ Placido rings supported this hypothesis. In summary, while NIBUT consistently showed longer values than fBUT, further investigations considering limitations and potential influencing factors are warranted for a comprehensive understanding of tear film stability assessment.
引用
收藏
页数:5
相关论文
共 50 条
  • [11] Manual interferometric device for routine non-invasive tear film break-up time assessment
    Pauk, Sania Vidas
    Petricek, Igor
    Tomic, Martina
    Bulum, Tomislav
    Jandrokovic, Sonja
    Kalauz, Miro
    Masnec, Sanja
    Jukic, Tomislav
    SEMINARS IN OPHTHALMOLOGY, 2021, 36 (03) : 94 - 102
  • [12] The Distribution and Influence Factors of Non-Invasive Tear Film Break-Up Time in Children [Letter]
    Rani, Anjali
    Yadav, Rakesh Kumar
    CLINICAL OPHTHALMOLOGY, 2025, 19 : 151 - 152
  • [13] Reliability of a New Non-invasive Tear Film Break-up Time Measurement Using a Keratograph
    Jeong, Seongyong
    Lee, Sang Bumm
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (09): : 1354 - 1360
  • [14] Ability of non-invasive tear break-up time to determine tear instability in contact lens wearers
    Muhafiz, Ersin
    Demir, Mehmet Sirac
    INTERNATIONAL OPHTHALMOLOGY, 2022, 42 (03) : 959 - 968
  • [15] Ability of non-invasive tear break-up time to determine tear instability in contact lens wearers
    Ersin Muhafiz
    Mehmet Siraç Demir
    International Ophthalmology, 2022, 42 : 959 - 968
  • [16] EFFECT OF TEAR SUBSTITUTES ON TEAR FILM BREAK-UP TIME
    LEMP, MA
    GOLDBERG, M
    RODDY, MR
    INVESTIGATIVE OPHTHALMOLOGY, 1975, 14 (03): : 255 - 258
  • [17] Tear film break-up time in rabbits
    Wei, Xiaojia E.
    Markoulli, Maria
    Zhao, Zhenjun
    Willcox, Mark D. P.
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2013, 96 (01) : 70 - 75
  • [18] Nichtinvasive Keratographen-Tränenfilmaufreißzeit im Vergleich zur Fluoreszein-TränenfilmaufreißzeitComparison of non-invasive tear film break-up time assessed by keratography with conventional fluorescein tear film break-up time
    Bujar Berisha
    Johannes Nepp
    Dieter Franz Rabensteiner
    Georg Wagner
    Ingrid Boldin
    Haleh Aminfar
    Jutta Horwath-Winter
    Spektrum der Augenheilkunde, 2022, 36 : 139 - 144
  • [19] Tear Film Dynamics and Imaging in Tear Break-up
    Braun, Richard J.
    Begley, Carolyn G.
    King-Smith, Peter Ewen
    Siddique, Javed
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [20] Diagnostic accuracy of non-invasive tear film break-up time assessed by the simple manual interferometric device
    Pauk, Sania Vidas
    Petricek, Igor
    Tomic, Martina
    Bulum, Tomislav
    Jandrokovic, Sonja
    Gulic, Maja Pauk
    Kalauz, Miro
    Gacina, Dina Lesin
    CONTACT LENS & ANTERIOR EYE, 2023, 46 (02):