Comparative analysis of tear film stability Automated non-invasive and fluorescein tear break-up time

被引:0
|
作者
Zeri, F. [1 ,2 ,3 ]
Rizzo, G. C. [1 ,2 ]
Ponzini, E. [1 ,2 ]
Borghesi, A. [1 ,2 ]
Tavazzi, S. [1 ,2 ]
机构
[1] Univ Milano Bicocca, Dipartimento Sci Mat, Milan, Italy
[2] Univ Milano Bicocca, Opt & Optometry Res Ctr, COMiB, Milan, Italy
[3] Aston Univ, Coll Hlth & Life Sci, Birmingham, England
关键词
D O I
10.1393/ncc/i2024-24336-0
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The tear film plays a crucial role in maintaining ocular surface physiology, with tear film stability being a key parameter. Tear break-up time (TBUT) is a common method for assessing tear film stability, involving the duration between a full blink and the initial disruption in the tear film. This study aimed to assess non-invasive break-up time (NIBUT) using an automatic approach and compare it with the traditional fluorescein break-up time (fBUT) method. Forty-three non- contact lens wearers were enrolled, and NIBUT data were collected using the Sirius+ instrument. fBUT was conducted using fluorescein sodium strips. Test-retest measurements were performed with 2 hours delay. NIBUT values were consistently longer than fBUT values (14.8 +/- 8.0 s vs. 8.7 +/- 5.2 s), aligning with existing literature. The results revealed good test-retest reliability for both methods; however, intraobserver repeatability was weak. A potential limitation was the non-randomized sequence of measurements, with fBUT consistently performed at the end due to its invasive nature. Variations in the coverage area of fBUT and NIBUT assessments, influenced by factors like the Placido disc dimension, and the lash shadows, may have contributed to shorter times with fBUT. Preliminary analyses focusing only on the corneal area covered by Sirius+ Placido rings supported this hypothesis. In summary, while NIBUT consistently showed longer values than fBUT, further investigations considering limitations and potential influencing factors are warranted for a comprehensive understanding of tear film stability assessment.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Comparison of non-invasive tear film break-up time assessed by keratography with conventional fluorescein tear film break-up time
    Berisha, Bujar
    Nepp, Johannes
    Rabensteiner, Dieter Franz
    Wagner, Georg
    Boldin, Ingrid
    Aminfar, Haleh
    Horwath-Winter, Jutta
    SPEKTRUM DER AUGENHEILKUNDE, 2022, 36 (06) : 139 - 144
  • [2] The non-invasive tear film break-up time in normal children
    Jones, Sophie M.
    Nischal, Ken K.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2013, 97 (09) : 1129 - 1133
  • [3] The utility of software-detected non-invasive tear break-up in comparison to fluorescein tear break-up measurements
    Pflugfelder, Stephen C.
    Kikukawa, Yasushi
    Tanaka, Shin
    Kosugi, Takuya
    FRONTIERS IN MEDICINE, 2024, 11
  • [4] Comparison of tear film break-up time measured by fluorescein staining and non-invasive measurement techniques
    Suzuki, Takashi
    Okajima, Yukinobu
    Itokawa, Takashi
    Hori, Yuichi
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [5] On the Automation of the Tear Film Non-Invasive Break-Up Test
    Carpente, A.
    Ramos, L.
    Barreira, N.
    Penedo, M. G.
    Pena-Verdeal, H.
    Giraldez, M. J.
    2014 IEEE 27TH INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS (CBMS), 2014, : 185 - 188
  • [6] Correlation of Non-invasive Tear Break-Up Time with Tear Osmolarity and Other Invasive Tear Function Tests
    Ozulken, Kemal
    Aydemir, Gozde Aksoy
    Tekin, Kemal
    Mumcuoglu, Tarkan
    SEMINARS IN OPHTHALMOLOGY, 2020, 35 (01) : 78 - 85
  • [7] The Distribution and Influence Factors of Non-Invasive Tear Film Break-Up Time in Children
    Zhao, Guo-Hong
    Wang, Jin-Da
    Liu, Mei-Rui
    Zhang, Li-Jun
    Sun, Yan
    Cao, Kai
    CLINICAL OPHTHALMOLOGY, 2024, 18 : 2697 - 2704
  • [8] Comparing automated and manual assessments of tear break-up time using different non-invasive devices and a fluorescein procedure
    Fabrizio Zeri
    Giulia Carlotta Rizzo
    Erika Ponzini
    Silvia Tavazzi
    Scientific Reports, 14
  • [9] Comparing automated and manual assessments of tear break-up time using different non-invasive devices and a fluorescein procedure
    Zeri, Fabrizio
    Rizzo, Giulia Carlotta
    Ponzini, Erika
    Tavazzi, Silvia
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [10] Thermographic evaluation of tear film break-up time to study tear film stability
    Su, Tai Yuan
    Ho, Wei Ting
    Chang, Shu Wen
    Chiang, Huihua Kenny
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2016, 99 : 36 - 40