Moisture and mould growth risk of cross-laminated timber basement walls: Laboratory and field investigation

被引:5
|
作者
Imamura, Fernanda Bezerra Tomaduci [1 ]
Chen, Yuxiang [1 ]
Deng, Lijun [1 ]
Chui, Ying Hei [1 ]
机构
[1] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 1H9, Canada
关键词
Basement; Cross-laminated timber (CLT); Moisture content; Mould growth;
D O I
10.1016/j.conbuildmat.2024.136150
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete is a commonly used material for constructing basements in low-rise buildings or residential houses in Canada, and as the use of cross-laminated timber (CLT) advances, the door to think of an alternative basement material to offset greenhouse gas emissions associated with reinforced concrete is open. However, the evaluation of CLT durability in below-grade environments, specifically concerning moisture and mould development, remains an unexplored field in research. Hence, this paper aims to analyze CLT's moisture response and mould growth risk in below-grade environments using field and laboratory experiments. A laboratory experiment was carried out to test a waterproofing membrane solution selected to compose the wall assembly in the field experiment. A large-scale experimental CLT basement was built at a cohesive soil site in Edmonton, Canada. The field experiment involved monitoring the relative humidity, temperature, and soil volumetric water content of the CLT panels, which measure 3 m by 6 m in plan and 2 m deep. Data was collected for an extended period from June 2022 to July 2023. The VVT model, developed by Hukka and Viitanen (1999) and updated by Viitanen et al., 2011 to estimate the mould growth level, was used to predict the risk of mould growth. The laboratory experiment showed that the waterproofing membrane is suitable for protection against moisture in a still-water setup. Field experiment results suggested that the primary moisture source was below the basement floor when the floor was finished inadequately. The moisture content of CLT walls was significantly increased by floor flooding and decreased by heating the basement interior. The acceptable mould index of three was surpassed during periods of abundant water below the basement floor due to flood events, showing that the CLT panels were at risk of mould growth development.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Seismic loss analysis of buildings with post-tensioned cross-laminated timber walls
    Wilson, Alex W.
    Phillips, Adam R.
    Motter, Christopher J.
    Lee, Ji Y.
    Dolan, J. Daniel
    EARTHQUAKE SPECTRA, 2021, 37 (01) : 324 - 345
  • [42] Experimental Testing of Rocking Cross-Laminated Timber Walls with Resilient Slip Friction Joints
    Hashemi, Ashkan
    Zarnani, Pouyan
    Masoudnia, Reza
    Quenneville, Pierre
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (01)
  • [43] Experimental investigation of cross-laminated timber deep beams with and without large openings
    van Gilst, Danielle L.
    Foster, Robert M.
    STRUCTURES, 2024, 67
  • [44] Investigation of the strength performance of anchoring connections for Japanese cedar cross-laminated timber
    Yeh, Min-Chyuan
    Lin, Yu-Li
    Wu, Zong-Syuan
    Chen, Bo-Ruei
    Taiwan Journal of Forest Science, 2020, 35 (01): : 37 - 60
  • [45] Lateral Performance of Cross-Laminated Timber Shear Walls Connected to Perpendicular Walls: Experimental Tests and Analytical Modeling
    D'Arenzo, Giuseppe
    Ruggeri, Elisabetta Maria
    Fossetti, Marinella
    JOURNAL OF STRUCTURAL ENGINEERING, 2024, 150 (08)
  • [46] Numerical Investigation of the Fire Resistance of Protected Cross-Laminated Timber Floor Panels
    Menis, Agnese
    Fragiacomo, Massimo
    Clemente, Isaia
    STRUCTURAL ENGINEERING INTERNATIONAL, 2012, 22 (04) : 523 - 532
  • [47] Experimental investigation on mechanical properties of Chinese fir composites as cross-laminated timber
    Kong, Fanxu
    Zhou, Bin
    An, Xin
    Wang, Feibin
    Wang, Shuo
    Ma, Panpan
    Que, Zeli
    INDUSTRIAL CROPS AND PRODUCTS, 2024, 213
  • [48] Field and Model Analysis of the Operational Energy Benefits of Cross-Laminated Timber Construction
    Salonvaara, Mikael
    Flechas, Gabriel Miguel
    Tabares-Velasco, Paulo Cesar
    MULTIPHYSICS AND MULTISCALE BUILDING PHYSICS, IBPC 2024, VOL 2, 2025, 553 : 512 - 517
  • [49] Wetting and drying performance of cross-laminated timber related to on-site moisture protections: Field measurements and hygrothermal simulations
    Wang, Lin
    Wang, Jieying
    Ge, Hua
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [50] Simplified Mechanistic Model for Seismic Response Prediction of Coupled Cross-Laminated Timber Rocking Walls
    Jin, Z.
    Pei, S.
    Blomgren, H.
    Powers, J.
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (02)