Moisture and mould growth risk of cross-laminated timber basement walls: Laboratory and field investigation

被引:5
|
作者
Imamura, Fernanda Bezerra Tomaduci [1 ]
Chen, Yuxiang [1 ]
Deng, Lijun [1 ]
Chui, Ying Hei [1 ]
机构
[1] Univ Alberta, Dept Civil & Environm Engn, Edmonton, AB T6G 1H9, Canada
关键词
Basement; Cross-laminated timber (CLT); Moisture content; Mould growth;
D O I
10.1016/j.conbuildmat.2024.136150
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Reinforced concrete is a commonly used material for constructing basements in low-rise buildings or residential houses in Canada, and as the use of cross-laminated timber (CLT) advances, the door to think of an alternative basement material to offset greenhouse gas emissions associated with reinforced concrete is open. However, the evaluation of CLT durability in below-grade environments, specifically concerning moisture and mould development, remains an unexplored field in research. Hence, this paper aims to analyze CLT's moisture response and mould growth risk in below-grade environments using field and laboratory experiments. A laboratory experiment was carried out to test a waterproofing membrane solution selected to compose the wall assembly in the field experiment. A large-scale experimental CLT basement was built at a cohesive soil site in Edmonton, Canada. The field experiment involved monitoring the relative humidity, temperature, and soil volumetric water content of the CLT panels, which measure 3 m by 6 m in plan and 2 m deep. Data was collected for an extended period from June 2022 to July 2023. The VVT model, developed by Hukka and Viitanen (1999) and updated by Viitanen et al., 2011 to estimate the mould growth level, was used to predict the risk of mould growth. The laboratory experiment showed that the waterproofing membrane is suitable for protection against moisture in a still-water setup. Field experiment results suggested that the primary moisture source was below the basement floor when the floor was finished inadequately. The moisture content of CLT walls was significantly increased by floor flooding and decreased by heating the basement interior. The acceptable mould index of three was surpassed during periods of abundant water below the basement floor due to flood events, showing that the CLT panels were at risk of mould growth development.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Cyclic load capacity and deformation mode of cross-laminated timber shear walls
    He, Minjuan
    Wang, Xijun
    Li, Zheng
    Tumu Gongcheng Xuebao/China Civil Engineering Journal, 2020, 53 (09): : 60 - 67
  • [22] Resistance of Cross-Laminated Timber Shear Walls for Platform-Type Construction
    Shahnewaz, Md
    Popovski, Marjan
    Tannert, Thomas
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (12)
  • [23] Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations
    McClung, Ruth
    Ge, Hua
    Straube, John
    Wang, Jieying
    BUILDING AND ENVIRONMENT, 2014, 71 : 95 - 110
  • [24] Yield mechanisms of base shear connections for cross-laminated timber shear walls
    Daneshvar, Hossein
    Niederwestberg, Jan
    Letarte, Jean-Philippe
    Chui, Ying Hei
    CONSTRUCTION AND BUILDING MATERIALS, 2022, 335
  • [25] Experimentally based q-factor estimation of cross-laminated timber walls
    Pozza, Luca
    Scotta, Roberto
    Trutalli, Davide
    Polastri, Andrea
    Smith, Ian
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2016, 169 (07) : 492 - 507
  • [26] The Influence of the Opening Size on the Shear Performance of the Cross-laminated Timber (CLT) Walls
    Zhang, Daiyuan
    Shen, Liming
    Zhu, Xudong
    Zhang, Sujun
    Gong, Meng
    BIORESOURCES, 2021, 16 (04) : 7070 - 7084
  • [27] Numerical study on the elastic buckling of cross-laminated timber walls subject to compression
    Carlos Pina, Juan
    Saavedra Flores, Erick I.
    Saavedra, Karin
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 199 (82-91) : 82 - 91
  • [28] Approximate R-Factor for Cross-Laminated Timber Walls in Multistory Buildings
    Pei, Shiling
    van de Lindt, John W.
    Popovski, Marjan
    JOURNAL OF ARCHITECTURAL ENGINEERING, 2013, 19 (04) : 245 - 255
  • [29] Novel Hold-Down Solutions for Cross-Laminated Timber Shear Walls
    Tannert, Thomas
    STRUCTURES CONGRESS 2022, 2022, : 232 - 238
  • [30] Modeling techniques for post-tensioned cross-laminated timber rocking walls
    Wilson, Alex W.
    Motter, Christopher J.
    Phillips, Adam R.
    Dolan, J. Daniel
    ENGINEERING STRUCTURES, 2019, 195 : 299 - 308