Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations

被引:81
|
作者
McClung, Ruth [1 ]
Ge, Hua [2 ]
Straube, John [3 ]
Wang, Jieying [4 ]
机构
[1] Morrison Hershfield, Vancouver, BC, Canada
[2] Concordia Univ, Montreal, PQ H3G 1M8, Canada
[3] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
[4] FPInnovations, Vancouver, BC V6T 1Z4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Cross-laminated timber (CLT) wall assemblies; Hygrothermal performance; Field test; Moisture content; Wood; Hygrothermal simulations;
D O I
10.1016/j.buildenv.2013.09.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Cross-laminated timber (CLT) panels have potential market in North America for building mid-rise or even taller structures due to their good structural and fire safety performance, light weight, and prefabricated nature. However, to ensure long-term durability when used in building enclosures, the hygrothermal performance of CLT wall assemblies needs to be evaluated in terms of wetting and drying potential. A test wall consisting of sixteen 0.6 m by 0.6 m CLT panels made of five different wood species (or species groups) and four different wall assemblies was constructed. The CLT panels were initially wetted with the moisture content (MC) in the surface layers approaching or exceeding 30%, and monitored for MCs and temperatures at different depths over one year in a building envelope test facility located in Waterloo, Ontario. The drying behaviour of these panels was analysed and the measured MCs over time were compared to simulation results using a commercial hygrothermal program. This field study showed that most of the CLT panels dried to below 26% within one month except for CLT walls with a low-permeance interior membrane, which indicated that none of the CLT walls would likely remain at a high MC level long enough to initiate decay under the conditions tested. The simulation results generally agree well with the field data at MCs below 26%. However, it was found that the hygrothermal simulation program tended to overestimate the MC in the centre of the panels by up to 5-10%, and simulated MCs at locations deep into the CLT panels were not as responsive to changes in ambient conditions, as the measurements indicated for assemblies with high exterior permeance. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 110
页数:16
相关论文
共 50 条
  • [1] Hygrothermal performance of cross-laminated timber wall assemblies: A stochastic approach
    Wang, Lin
    Ge, Hua
    BUILDING AND ENVIRONMENT, 2016, 97 : 11 - 25
  • [2] Wetting and drying performance of cross-laminated timber related to on-site moisture protections: Field measurements and hygrothermal simulations
    Wang, Lin
    Wang, Jieying
    Ge, Hua
    12TH NORDIC SYMPOSIUM ON BUILDING PHYSICS (NSB 2020), 2020, 172
  • [3] Designing highly insulated cross-laminated timber external walls in terms of hygrothermal performance: Field measurements and simulations
    Kukk, Villu
    Kaljula, Laura
    Kers, Jaan
    Kalamees, Targo
    BUILDING AND ENVIRONMENT, 2022, 212
  • [4] Impact of built-in moisture on the design of hygrothermally safe cross-laminated timber external walls: A stochastic approach
    Kukk, Villu
    Kers, Jaan
    Kalamees, Targo
    Wang, Lin
    Ge, Hua
    BUILDING AND ENVIRONMENT, 2022, 226
  • [5] Hygrothermal properties analysis of cross-laminated timber wall with internal and external insulation systems
    Cho, Hyun Mi
    Wi, Seunghwan
    Chang, Seong Jin
    Kim, Sumin
    JOURNAL OF CLEANER PRODUCTION, 2019, 231 (1353-1363) : 1353 - 1363
  • [6] Numerical analysis of hygrothermal properties and behavior of Korean based cross-laminated timber (CLT) wall system to deduce optimal assemblies
    Yoo, Jiwon
    Chang, Seong Jin
    Lee, Jongki
    Wi, Seunghwan
    Kim, Sumin
    JOURNAL OF CLEANER PRODUCTION, 2019, 213 : 1217 - 1227
  • [7] Hygrothermal characterization and modeling of cross-laminated timber in the building envelope
    Kordziel, Steven
    Glass, Samuel V.
    Boardman, Charles R.
    Munson, Robert A.
    Zelinka, Samuel L.
    Pei, Shiling
    Tabares-Velasco, Paulo Cesar
    BUILDING AND ENVIRONMENT, 2020, 177 (177)
  • [8] Thermal performance of cross-laminated timber (CLT) and cross-laminated bamboo and timber (CLBT) panels
    Shan, Bo
    Chen, Bozhang
    Wen, Jie
    Xiao, Yan
    ARCHITECTURAL ENGINEERING AND DESIGN MANAGEMENT, 2023, 19 (05) : 511 - 530
  • [9] Monitoring Moisture Performance of Cross-Laminated Timber Building Elements during Construction
    Schmidt, Evan
    Riggio, Mariapaola
    BUILDINGS, 2019, 9 (06)
  • [10] Model validation and 2-D hygrothermal simulations of wetting and drying behavior of cross-laminated timber
    Wang, Lin
    Ge, Hua
    Wang, Jieying
    JOURNAL OF BUILDING PHYSICS, 2023, 46 (06) : 737 - 761