Impact of built-in moisture on the design of hygrothermally safe cross-laminated timber external walls: A stochastic approach

被引:10
|
作者
Kukk, Villu [1 ,6 ]
Kers, Jaan [2 ]
Kalamees, Targo [1 ,5 ]
Wang, Lin [3 ]
Ge, Hua [4 ]
机构
[1] Tallinn Univ Technol, nZEB Res Grp, Tallinn, Estonia
[2] Tallinn Univ Technol, Lab Wood Technol, Tallinn, Estonia
[3] Inst Res Construct, Natl Res Council Canada, Tallinn, Estonia
[4] Concordia Univ, Dept Bldg Civil & Environm Engn, Tallinn, Estonia
[5] Tallinn Univ Technol, FinEst Ctr Smart Cities, FinEst Ctr, Tallinn, Estonia
[6] Ehitajate tee 5, EE-19086 Tallinn, Estonia
基金
欧盟地平线“2020”;
关键词
Cross-laminated timber; CLT; Moisture safety; Stochastic approach; Hygrothermal performance; Hygrothermal criteria; FIELD-MEASUREMENTS; PERFORMANCE; WOOD; DURABILITY; ASSEMBLIES; PREDICTION; DECAY;
D O I
10.1016/j.buildenv.2022.109736
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In terms of hygrothermal performance, solid wood panels composed of cross-laminated timber (CLT) are sen-sitive to moisture. However, to the best of our knowledge, no clear indications of critical initial moisture con-ditions for CLT envelopes regarding the dry-out of built-in moisture have been provided. Therefore, our main objective was to set critical limit values for CLT external wall design in terms of their initial moisture content (built-in moisture) and dry-out capacity (vapour resistance of wall layers) using a stochastic approach. The focus is on five types of CLT external walls that differ in their dry-out capacity. The key factors in the hygrothermally safe design of the CLT external envelope are sufficient dry-out capacity and control of the CLT initial moisture content level during the construction phase. The results of our stochastic analysis confirmed that a high initial moisture content in CLT causes a high mould growth risk when CLT is covered with vapour tight layers. Therefore, the limit values for critical initial moisture content of CLT and the water vapour resistance of the wall layers that ensure dry-out capacity of different external walls to prevent the risk of mould growth on the CLT surface in a cold and humid climate were determined. These limit values take into consideration the weather conditions during the construction phase and classes of material sensitivity to mould growth.
引用
收藏
页数:19
相关论文
共 15 条
  • [1] Hygrothermal performance of cross-laminated timber wall assemblies with built-in moisture: field measurements and simulations
    McClung, Ruth
    Ge, Hua
    Straube, John
    Wang, Jieying
    BUILDING AND ENVIRONMENT, 2014, 71 : 95 - 110
  • [2] Structural Analysis and Design of Sustainable Cross-Laminated Timber Foundation Walls
    Daneshvar, Hossein
    Fakhrzarei, Mahboobeh
    Imamura, Fernanda
    Chen, Yuxiang
    Deng, Lijun
    Chui, Ying Hei
    BUILDINGS, 2022, 12 (07)
  • [3] Hygrothermal performance of cross-laminated timber wall assemblies: A stochastic approach
    Wang, Lin
    Ge, Hua
    BUILDING AND ENVIRONMENT, 2016, 97 : 11 - 25
  • [4] Moisture and mould growth risk of cross-laminated timber basement walls: Laboratory and field investigation
    Imamura, Fernanda Bezerra Tomaduci
    Chen, Yuxiang
    Deng, Lijun
    Chui, Ying Hei
    CONSTRUCTION AND BUILDING MATERIALS, 2024, 428
  • [5] Reliability-based overstrength factors of cross-laminated timber shear walls for seismic design
    Aloisio, Angelo
    Fragiacomo, Massimo
    ENGINEERING STRUCTURES, 2021, 228
  • [6] The lateral load resistance of unclassified cross-laminated timber walls: Experimental tests and theoretical approach
    Wadi, H.
    Amziane, S.
    Taazount, M.
    ENGINEERING STRUCTURES, 2018, 166 : 402 - 412
  • [7] Designing highly insulated cross-laminated timber external walls in terms of hygrothermal performance: Field measurements and simulations
    Kukk, Villu
    Kaljula, Laura
    Kers, Jaan
    Kalamees, Targo
    BUILDING AND ENVIRONMENT, 2022, 212
  • [8] Moisture risk assessment of cross-laminated timber walls: Perspectives on climate conditions and water vapor resistance performance of building materials
    Chang, Seong Jin
    Wi, Seunghwan
    Kang, Seog Goo
    Kim, Sumin
    BUILDING AND ENVIRONMENT, 2020, 168
  • [9] Seismic strengthening of existing RC buildings with external cross-laminated timber (CLT) walls hosting an integrated energetic and architectural renovation
    Lorenzo Badini
    Stephan Ott
    Patrik Aondio
    Stefan Winter
    Bulletin of Earthquake Engineering, 2022, 20 : 5963 - 6006
  • [10] Seismic strengthening of existing RC buildings with external cross-laminated timber (CLT) walls hosting an integrated energetic and architectural renovation
    Badini, Lorenzo
    Ott, Stephan
    Aondio, Patrik
    Winter, Stefan
    BULLETIN OF EARTHQUAKE ENGINEERING, 2022, 20 (11) : 5963 - 6006