Comprehensive dosimetric commissioning of proton minibeam radiotherapy on a single gantry proton system

被引:0
|
作者
Lin, Yuting [1 ]
Li, Wangyao [1 ]
Wang, Aoxiang [1 ,2 ]
Johnson, Daniel [1 ]
Gan, Gregory N. [1 ]
Gao, Hao [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Radiat Oncol, Kansas City, KS 66103 USA
[2] Huazhong Univ Sci & Technol, Dept Biomed Engn, Wuhan, Peoples R China
来源
FRONTIERS IN ONCOLOGY | 2024年 / 14卷
关键词
proton therapy; spatially fractionated radiotherapy; proton mini-beam; small field dosimetry; film dosimetry; proton dosimetry; FRACTIONATED RADIATION-THERAPY;
D O I
10.3389/fonc.2024.1421869
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background Proton minibeam radiation therapy (pMBRT) can deliver spatially fractionated dose distributions with submillimeter resolution. These dose distributions exhibit significant heterogeneity in both depth and lateral directions. Accurate characterization of pMBRT doses requires dosimetry devices with high spatial resolution and a wide dynamic range. Furthermore, the dependency of dosimetric measurements on Linear Energy Transfer (LET), as observed in conventional proton therapy, is also present in pMBRT depth dose measurements.Purpose This work demonstrates the process of performing comprehensive dosimetric measurements to characterize the pMBRT collimator on a clinical single-gantry proton machine, utilizing commercially available dosimetry devices.Methods The minibeam collimator is designed to be mounted on the clinical nozzle as a beam-modifying accessory. Three collimators, each with a slit opening of 0.4 mm, are thoroughly evaluated. The center-to-center (c-t-c) distances of the slits for these collimators are 2.8 mm, 3.2 mm, and 4.0 mm, respectively. High spatial resolution dosimetry devices are essential for PMBRT dose characterizations. To meet this requirement, two-dimensional (2D) dose measurement devices, Gafchromic films, are used to measure lateral profiles at various depths. Films are also used for depth dose profile measurements in solid water. Additionally, high-resolution point dose detectors, microDiamond, and Razor diode detectors are employed for lateral profile measurements at various depths. Percent depth dose (PDD) measurements of pMBRT in solid water, with various proton energies, collimators, and air gaps, are performed using Gafchromic films. The film's LET dependency for proton beams is corrected to ensure accurate pMBRT PDD measurements. The Monte Carlo simulation tool TOPAS is utilized to compare and validate all experimental measurements.Results At depths where LET is not a concern, film dose measurements were consistent with microDiamond and Razor diode point measurements. The point detectors need to be orientated with the thin side aligned to the incoming beam. Comparison of the lateral dose profiles extracted from TOPAS simulations, films, microDiamond, and Razor diode detectors shows a passing rate exceeding 98% in 1D gamma analysis at 3% 0.1 mm criteria.However, when the microDiamond detector is orientated to face the pMBRT beam, its spatial resolution may not be sufficient to capture the peak and valley dose accurately. Nevertheless, an accuracy within 2% can still be achieved when comparing the average dose. The PDD measurements show that the peak valley dose ratio (PVDR) of pMBRT can be altered at different depths with different air gaps using the same collimator or different collimators of different c-t-c distances.Conclusion Our study demonstrates that comprehensive dose measurements for pMBRT can be conducted using standard clinical dose measurement devices. These measurements are indispensable for guiding and ensuring accurate dose reporting in pre-clinical studies using the pMBRT technique.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Proton minibeam radiation therapy (pMBRT) as a new radiotherapy approach
    Schmid, T. E.
    Hunger, A.
    Sammer, M.
    Zahnbrecher, E.
    Reindl, J.
    Ilicic, K.
    Walsh, D.
    Greubel, C.
    Schwarz, B.
    Wilkens, J. J.
    Dollinger, G.
    Combs, S. E.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2018, 194 : S97 - S97
  • [22] Recommendations for dosimetric commissioning of proton therapy for iris melanoma
    Duzenli, Cheryl
    Beaudry, Joel
    Lindsay, Clay
    Lee, Richard
    Penner, Crystal
    Strgar, Vince
    Hoehr, Cornelia
    MEDICAL PHYSICS, 2017, 44 (08) : 4375 - 4375
  • [23] Dosimetric commissioning of a TPS for a synchrotron-based proton PBS delivery system
    Kragl, G.
    Boehlen, T.
    Carlino, A.
    Grevillot, L.
    Palmans, H.
    Elia, A.
    Knaeusl, B.
    Osorio, J.
    Dreindl, R.
    Hopfgartner, J.
    Vatnitsky, S.
    Stock, M.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S838 - S838
  • [24] Preliminary Dosimetric Study of Proton Minibeam Radiation Therapy for the Treatment of Choroidal Melanoma
    Kim, Myeongsoo
    Kim, Sang Soo
    Kim, Haksoo
    Moon, Sung Ho
    Lim, Young Kyung
    Hwang, Ui-Jung
    Choi, Sang Hyoun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2020, 77 (05) : 447 - 451
  • [25] Preliminary Dosimetric Study of Proton Minibeam Radiation Therapy for the Treatment of Choroidal Melanoma
    Myeongsoo Kim
    Sang Soo Kim
    Haksoo Kim
    Sung Ho Moon
    Young Kyung Lim
    Ui-Jung Hwang
    Sang Hyoun Choi
    Journal of the Korean Physical Society, 2020, 77 : 447 - 451
  • [26] Reduced side effects by proton minibeam radiotherapy in a mouse ear model
    Schmid, T. E.
    Girst, S.
    Greubel, C.
    Reindl, J.
    Siebenwirth, C.
    Ilicic, K.
    Walsh, D. W. M.
    Dollinger, G.
    Wilkens, J.
    Multhoff, G.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S485 - S485
  • [27] Dosimetric uncertainty in prostate cancer proton radiotherapy
    Lin, Liyong
    Vargas, Carlos
    Hsi, Wen
    Indelicato, Daniel
    Slopsema, Roelf
    Li, Zuofeng
    Yeung, Daniel
    Horne, Dave
    Palta, Jatinder
    MEDICAL PHYSICS, 2008, 35 (11) : 4800 - 4807
  • [28] Reduced side effects by proton minibeam radiotherapy in a mouse ear model
    Schmid, T. E.
    Girst, S.
    Greubel, C.
    Reindl, J.
    Siebenwirth, C.
    Ilicic, K.
    Walsh, D. W. M.
    Dollinger, G.
    Wilkens, J.
    Multoff, G.
    Combs, S. E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S95 - S95
  • [29] Optimization of beam arrangements in proton minibeam radiotherapy by cell survival simulations
    Sammer, Matthias
    Greubel, Christoph
    Girst, Stefanie
    Dollinger, Guenther
    MEDICAL PHYSICS, 2017, 44 (11) : 6096 - 6104
  • [30] Commissioning of the On-Board Cone-Beam CT System Equipped On the Rotating Gantry of a Proton Therapy System
    Takao, S.
    Shimizu, S.
    Miyamoto, N.
    Matsuura, T.
    Toramatsu, C.
    Nihongi, H.
    Yamada, T.
    Matsuda, K.
    Sasaki, T.
    Nagamine, Y.
    Baba, R.
    Umekawa, T.
    Umegaki, K.
    Shirato, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 386 - 387