Dosimetric characteristics of transparent bolus for external beam radiotherapy

被引:0
|
作者
Govindaraj K. [1 ,2 ]
Senthilkumar S. [2 ,3 ]
Jeevan Ram R.K. [4 ]
机构
[1] Department of Radiotherapy, Vadamalayan Integrated Cancer Centre, Madurai
[2] Research and Development Centre, Bharathiar University, Coimbatore
[3] Department of Radiotherapy, Madurai Medical College and Government Rajaji Hospital, Madurai
[4] Department of Medical Physics, Bharathidasan University, Tiruchirapalli
关键词
Bolus; Radiotherapy; Surface dose;
D O I
10.22038/ijmp.2019.37129.1470
中图分类号
学科分类号
摘要
Introduction: In radiotherapy, the bolus is often used while treating the tumor under the uneven surfaces of the patients for correcting the anatomical irregularities and increasing skin dose. Wet cotton and wet gauze are still used in developing countries, since the use of wet cotton and wet gauze has certain disadvantages, there is a need for transparent bolus which should be similar to a universally accepted bolus in terms of properties with a lower cost (50% less expensive). Material and Methods: The present study was conducted to investigate the characteristics of transparent bolus (Senflab) material, such as transmission factor, percentage depth dose (PDD), stability over time and high dose, homogeneity and transparency using 6 and 15 MV photons beam and 12, 15, and 18 MeV electrons beam. Moreover, the new bolus material was compared with those of the commercially available Superflab and RW3 slab. Results: The percentage difference in the transmission factor of Senflab was less than ±1.9%, compared with Superflab and RW3. For PDD, the percentage difference was ±2.88% and ±1.26% for photons and electron beams, respectively. The performance of bolus remained constant both physically and dosimetrically after higher dose exposure. The percentage standard deviation was 0.0002% for a period of one month, and 0.0003% for the homogeneity. The transparency of the bolus material was good enough to display the set radiation treatment field. Conclusion: This study shows the suitability of the new bolus for routine use in radiotherapy. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:410 / 415
页数:5
相关论文
共 50 条
  • [41] High-dose-rate brachytherapy with external beam radiotherapy in the treatment of carcinoma of cervix: dosimetric and radiobiologic analysis
    Passi, Kamlesh
    Kehwar, Than S.
    Vashistha, Rajesh
    Singh, Bikramjit
    Jain, Veena
    Gupta, Sureshchandra J.
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2009, 8 (04) : 215 - 227
  • [42] CONTOUR AGREEMENT? ACCURACY? WHAT ABOUT A DOSIMETRIC PERSPECTIVE ON WHEN MILLIMETERS MATTER IN CERVIX EXTERNAL BEAM RADIOTHERAPY?
    Menon, Geetha
    Rose, Brenda
    Oliva, Patricia
    Huang, Fleur
    RADIOTHERAPY AND ONCOLOGY, 2023, 186 : S92 - S92
  • [43] Impact of dosimetric differences between CT and MRI derived target volumes for external beam cervical cancer radiotherapy
    Batumalai, Vikneswary
    Burke, Siobhan
    Roach, Dale
    Lim, Karen
    Dinsdale, Glen
    Jameson, Michael
    Ochoa, Cesar
    Veera, Jacqueline
    Holloway, Lois
    Vinod, Shalini
    BRITISH JOURNAL OF RADIOLOGY, 2020, 93 (1114):
  • [44] Dosimetric Characteristics of a PIN Diode for Radiotherapy Application
    Kumar, Rajesh
    Sharma, S. D.
    Philomina, A.
    Topkar, Anita
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2014, 13 (04) : 361 - 367
  • [45] In vivo dosimetry in external beam radiotherapy
    Mijnheer, Ben
    Beddar, Sam
    Izewska, Joanna
    Reft, Chester
    MEDICAL PHYSICS, 2013, 40 (07)
  • [46] EXTERNAL BEAM RADIOTHERAPY FOR THYROID CANCER
    HARMER, CL
    ANNALES DE RADIOLOGIE, 1977, 20 (08) : 791 - 800
  • [47] MRI for external beam radiotherapy guidance
    Lagendijk, J. J. W.
    Raaymakers, B. W.
    van Vulpen, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S65 - S65
  • [48] External beam radiotherapy for hepatocellular carcinoma
    Baker, Holly
    LANCET GASTROENTEROLOGY & HEPATOLOGY, 2018, 3 (06): : 380 - 380
  • [49] Automatization of dosimetric analysis and verification of external radiotherapy treatment plans
    Gutierrez Ruiz, Marina
    Astudillo, Rodrigo
    Gillard Barroso, Nicolas
    Suarez Alvarez, Noelia
    Camacho, Guillermo
    Reguilon, Ana
    Uzquiza, Javier
    Alonso, Jorge
    Gomez, Fernando
    Fabregat, Rosa
    Delgado, Paula
    Ruiz, Samuel
    Andres Vazquez, Jose
    Ignacio Raba, Juan
    Teresa Pacheco, Maria
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S4932 - S4935
  • [50] Combination of internal and external beam radiotherapy
    Giraudet, A. -L.
    CANCER RADIOTHERAPIE, 2023, 27 (08): : 754 - 758