Impact of dosimetric differences between CT and MRI derived target volumes for external beam cervical cancer radiotherapy

被引:7
|
作者
Batumalai, Vikneswary [1 ,2 ,3 ]
Burke, Siobhan [1 ]
Roach, Dale [2 ,3 ]
Lim, Karen [1 ,3 ]
Dinsdale, Glen [1 ]
Jameson, Michael [1 ,2 ,3 ,4 ]
Ochoa, Cesar [1 ]
Veera, Jacqueline [5 ]
Holloway, Lois [1 ,2 ,3 ,4 ,6 ]
Vinod, Shalini [1 ,2 ,3 ]
机构
[1] South Western Sydney Local Hlth Dist, Dept Radiat Oncol, Warwick Farm, NSW, Australia
[2] Ingham Inst Appl Med Res, Liverpool, NSW, Australia
[3] Univ New South Wales, South Western Clin Sch, Sydney, NSW, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[5] Peter MaCallum Canc Ctr, Melbourne, Vic, Australia
[6] Univ Sydney, Sch Phys, Inst Med Phys, Sydney, NSW, Australia
来源
BRITISH JOURNAL OF RADIOLOGY | 2020年 / 93卷 / 1114期
关键词
TREATMENT PLANNING SYSTEM; INTEROBSERVER VARIABILITY; RADIATION-THERAPY; DELINEATION; HEAD; QUALITY;
D O I
10.1259/bjr.20190564
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The use of MRI is becoming more prevalent in cervical cancer external beam radiotherapy (RT). The aim of this study was to investigate the impact of dosi-metric differences between CT and MRI-derived target volumes for cervical cancer external beam RT. Methods: An automated planning technique for volumetric modulated arc therapy was developed. Two auto-mated planning plans were generated for 18 cervical cancer patients where planning target volumes (PTV5) were generated based on CT or MRI data alone. Dose metrics for planning target volumes and organs at risk (OARs) were compared to analyse any differences based on imaging modality. Results: All treatment plans were clinically acceptable, Bladder doses (V40) were lower in MRI-based plans (p = 0.04, 53.6 +/- 17.2 % vs 60.3 +/- 13,1 % for MRI vs CT, respectively). The maximum dose for left iliac crest showed lower doses in CT-based plans (p = 0.02, 47,8 +/- 0.7Gy vs 47.4 +/- 0.4 Gy MRI vs CT, respectively). No significant differences were seen for other OARs. Conclusions: The dosimetric differences of CT- and MRIbased contouring variability for this study was small. CT remains the standard imaging modality for volume delineation for these patients. Advances in knowledge: This is the first study to evaluate the dosimetric implications of imaging modality on target and OAR doses in cervical cancer external beam RT.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Dosimetric impact of imaging modality (CT versus MRI) for cervical cancer radiotherapy
    Burke, S.
    Batumalai, V.
    Lim, K.
    Roach, D.
    Dinsdale, G.
    Mahoney, L.
    Jameson, M.
    Ochoa, C.
    Veera, J.
    Holloway, L.
    Vinod, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127
  • [2] Dosimetric impact of bladder volume on organs at risk during external beam radiotherapy of cervical cancer
    Mohamadian, Niloofar
    Nasseri, Shahrokh
    Hosseini, Sare
    Molaie, Fatemeh
    Zarifi, Shiva
    Eskandari, Azam
    Momennezhad, Mehdi
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (13) : 1351 - 1356
  • [3] The Changes of Target Volumes between External Beam Radiotherapy and Brachytherapy and between Each Fraction of MRI-Guided Brachytherapy for GYN Cancer
    Kim, Y.
    Sun, W.
    Bhatia, S. K.
    Jacobson, G. M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S414 - S414
  • [4] External beam radiotherapy target volumes for cervical cancer: A multi-institutional study assessing contouring variability on magnetic resonance imaging (MRI) and computer tomography (CT)
    Veera, J.
    Vinod, S. K.
    Holloway, L. C.
    Borok, N.
    Dimigen, M.
    Pogson, E.
    Lim, K.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S240 - S240
  • [5] The dosimetric impact of target volume delineation variation for cervical cancer radiotherapy
    Eminowicz, Gemma
    Rompokos, Vasilis
    Stacey, Christopher
    McCormack, Mary
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (03) : 493 - 499
  • [6] Fan beam CT-guided online adaptive external radiotherapy of uterine cervical cancer: a dosimetric evaluation
    Haibo Peng
    Jie Zhang
    Ningyue Xu
    Yangang Zhou
    Huigang Tan
    Tao Ren
    BMC Cancer, 23
  • [7] Fan beam CT-guided online adaptive external radiotherapy of uterine cervical cancer: a dosimetric evaluation
    Peng, Haibo
    Zhang, Jie
    Xu, Ningyue
    Zhou, Yangang
    Tan, Huigang
    Ren, Tao
    BMC CANCER, 2023, 23 (01)
  • [8] CT substitute derived from MRI for external beam prostate radiotherapy
    Dowling, J.
    Pichler, P.
    Sun, J.
    Rivest-Henault, D.
    Ghose, S.
    Martin, J.
    Wratten, C.
    Stanwell, P.
    Fripp, J.
    Greer, P.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S135 - S135
  • [9] The Potential Value of MRI in External-Beam Radiotherapy for Cervical Cancer
    Cree, A.
    Liysey, J.
    Barraclough, L.
    Dubec, M.
    Hambrock, T.
    Van Herk, M.
    Choudhury, A.
    McWilliam, A.
    CLINICAL ONCOLOGY, 2018, 30 (11) : 737 - 750
  • [10] The dosimetric consequences of delineation variation for cervical external beam radiotherapy
    Eminowicz, G.
    Rompokos, V.
    Stacey, C.
    McCormack, M.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S455 - S456