Dosimetric characteristics of transparent bolus for external beam radiotherapy

被引:0
|
作者
Govindaraj K. [1 ,2 ]
Senthilkumar S. [2 ,3 ]
Jeevan Ram R.K. [4 ]
机构
[1] Department of Radiotherapy, Vadamalayan Integrated Cancer Centre, Madurai
[2] Research and Development Centre, Bharathiar University, Coimbatore
[3] Department of Radiotherapy, Madurai Medical College and Government Rajaji Hospital, Madurai
[4] Department of Medical Physics, Bharathidasan University, Tiruchirapalli
关键词
Bolus; Radiotherapy; Surface dose;
D O I
10.22038/ijmp.2019.37129.1470
中图分类号
学科分类号
摘要
Introduction: In radiotherapy, the bolus is often used while treating the tumor under the uneven surfaces of the patients for correcting the anatomical irregularities and increasing skin dose. Wet cotton and wet gauze are still used in developing countries, since the use of wet cotton and wet gauze has certain disadvantages, there is a need for transparent bolus which should be similar to a universally accepted bolus in terms of properties with a lower cost (50% less expensive). Material and Methods: The present study was conducted to investigate the characteristics of transparent bolus (Senflab) material, such as transmission factor, percentage depth dose (PDD), stability over time and high dose, homogeneity and transparency using 6 and 15 MV photons beam and 12, 15, and 18 MeV electrons beam. Moreover, the new bolus material was compared with those of the commercially available Superflab and RW3 slab. Results: The percentage difference in the transmission factor of Senflab was less than ±1.9%, compared with Superflab and RW3. For PDD, the percentage difference was ±2.88% and ±1.26% for photons and electron beams, respectively. The performance of bolus remained constant both physically and dosimetrically after higher dose exposure. The percentage standard deviation was 0.0002% for a period of one month, and 0.0003% for the homogeneity. The transparency of the bolus material was good enough to display the set radiation treatment field. Conclusion: This study shows the suitability of the new bolus for routine use in radiotherapy. © 2019, Mashhad University of Medical Sciences.
引用
收藏
页码:410 / 415
页数:5
相关论文
共 50 条
  • [21] Comparing the physical and dosimetric characteristics of cylindrical and beam shaper intraoperative radiotherapy applicators
    Baghani, Hamid Reza
    Heidarloo, Nematollah
    Aghamiri, Seyed Mahmoud Reza
    Mahdavi, Seyed Rabi
    RADIATION PHYSICS AND CHEMISTRY, 2019, 158 : 22 - 36
  • [22] Dosimetric impact of bladder volume on organs at risk during external beam radiotherapy of cervical cancer
    Mohamadian, Niloofar
    Nasseri, Shahrokh
    Hosseini, Sare
    Molaie, Fatemeh
    Zarifi, Shiva
    Eskandari, Azam
    Momennezhad, Mehdi
    RADIATION PROTECTION DOSIMETRY, 2023, 199 (13) : 1351 - 1356
  • [23] A dosimetric comparison of two external beam radiotherapy techniques: 3DCRT & Tomotherapy in APBI
    Rajan, R.
    Kunheri, B.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S926 - S928
  • [24] Physical and dosimetric characterization of thermoset shape memory bolus developed for radiotherapy
    Aoyama, Takahiro
    Uto, Koichiro
    Shimizu, Hidetoshi
    Ebara, Mitsuhiro
    Kitagawa, Tomoki
    Tachibana, Hiroyuki
    Suzuki, Kojiro
    Kodaira, Takeshi
    MEDICAL PHYSICS, 2020, 47 (12) : 6103 - 6112
  • [25] Dosimetric characteristics of active solid state detectors in a 60 MeV proton radiotherapy beam
    Sowa, Urszula
    Nowak, Tomasz
    Michalec, Barbara
    Mierzwinska, Gabriela
    Swakon, Jan
    Olko, Pawel
    NUKLEONIKA, 2012, 57 (04) : 491 - 495
  • [26] Comparing the dosimetric characteristics of the electron beam from dedicated intraoperative and conventional radiotherapy accelerators
    Baghani, Hamid Reza
    Aghamiri, Seyed Mahmoud Reza
    Mahdavi, Seyed Rabi
    Akbari, Mohammad Esmail
    Mirzaei, Hamid Reza
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 62 - 72
  • [27] Exploration of the optimal dosimetric parameters to predict late rectal toxicity in external beam radiotherapy for prostate cancer
    Dahmane, R.
    Carrier, J. F.
    Lacroix, F.
    Taussky, D.
    EJC SUPPLEMENTS, 2009, 7 (02): : 420 - 420
  • [28] Defining the potential for sexual structures-sparing for prostate cancer external beam radiotherapy: A dosimetric study
    Guevelou, Jennifer Le
    Houssayni, Ayad
    Largent, Axel
    Lafond, Caroline
    Acosta, Oscar
    Simon, Antoine
    de Crevoisier, Renaud
    CANCER RADIOTHERAPIE, 2024, 28 (08): : 686 - 692
  • [29] A study of the clinical, treatment planning and dosimetric feasibility of dose painting in external beam radiotherapy of prostate cancer
    Blake, Steve W.
    Stapleton, Alison
    Brown, Andrew
    Curtis, Sian
    Ash-Miles, Janice
    Dennis, Emma
    Masson, Susan
    Bowers, Dawn
    Hilman, Serena
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 15 : 66 - 71
  • [30] A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy
    Prabhakar, Ramachandran
    Cramb, Jim
    Kron, Tomas
    MEDICAL PHYSICS, 2011, 38 (12) : 6539 - 6552