X-Ray Image Generation as a Method of Performance Prediction for Real-Time Inspection: a Case Study

被引:0
|
作者
Andriiashen, Vladyslav [1 ]
van Liere, Robert [1 ,2 ]
van Leeuwen, Tristan [1 ,3 ]
Batenburg, K. Joost [1 ,4 ]
机构
[1] Ctr Wiskunde Informat, Computat Imaging, Sci Pk 123, NL-1098 XG Amsterdam, Netherlands
[2] Tech Univ Eindhoven, Fac Wiskunde Informat, Groene Loper 5, NL-5612 AZ Eindhoven, Netherlands
[3] Univ Utrecht, Math Inst, Budapestlaan 6, NL-3584 CD Utrecht, Netherlands
[4] Leiden Univ, Leiden Inst Adv Comp Sci, Niels Bohrweg 1, NL-2333 CA Leiden, Netherlands
关键词
X-ray inspection; System Design; Dual-energy X-ray; Deep Convolutional neural networks; Probability of detection; NOISE; OPTIMIZATION; SIMULATION; CT;
D O I
10.1007/s10921-024-01091-8
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
X-ray imaging can be efficiently used for high-throughput in-line inspection of industrial products. However, designing a system that satisfies industrial requirements and achieves high accuracy is a challenging problem. The effect of many system settings is application-specific and difficult to predict in advance. Consequently, the system is often configured using empirical rules and visual observations. The performance of the resulting system is characterized by extensive experimental testing. We propose to use computational methods to substitute real measurements with generated images corresponding to the same experimental settings. With this approach, it is possible to observe the influence of experimental settings on a large amount of data and to make a prediction of the system performance faster than with conventional methods. We argue that a high accuracy of the image generator may be unnecessary for an accurate performance prediction. We propose a quantitative methodology to characterize the quality of the generation model using Probability of Detection curves. The proposed approach can be adapted to various applications and we demonstrate it on the poultry inspection problem. We show how a calibrated image generation model can be used to quantitatively evaluate the effect of the X-ray exposure time on the performance of the inspection system.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] THE USE OF MICROFOCUS X-RAY IN REAL-TIME APPLICATIONS
    RIDDER, H
    MATERIALS EVALUATION, 1981, 39 (10) : A17 - A17
  • [42] REAL-TIME X-RAY μ-IMAGING OF LIVING ORGANISMS
    Dammer, Jiri
    Holy, Tomas
    Jakubek, Jan
    Jakubek, Martin
    Pospisil, Stanislav
    Vavrik, Daniel
    Hanus, Robert
    Weyda, Frantisek
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2008, 4 : 640 - +
  • [43] A system of X-ray visualization in the real-time mode
    O. A. Bashutin
    Instruments and Experimental Techniques, 2015, 58 : 268 - 271
  • [44] Real-Time Data Processing for X-Ray Spectroscopy
    Adams, J. S.
    Bandler, S. R.
    Brown, L. E.
    Boyce, K. R.
    Chiao, M. P.
    Doriese, W. B.
    Eckart, M. E.
    Hilton, G. C.
    Kelley, R. L.
    Kilbourne, C. A.
    Porter, F. S.
    Rabin, M. W.
    Smith, S. J.
    Stewart, D. D.
    Ullom, J. N.
    LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 274 - +
  • [45] Real-time x-ray imaging with flat panels
    Gilblom, D
    Colbeth, R
    Batts, M
    Meyer, B
    PROCESS CONTROL AND SENSORS FOR MANUFACTURING, 1998, 3399 : 213 - 223
  • [46] A system of X-ray visualization in the real-time mode
    Bashutin, O. A.
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2015, 58 (02) : 268 - 271
  • [47] Development of real-time x-ray microtomography system
    Takano, H.
    Morikawa, M.
    Konishi, S.
    Azuma, H.
    Shimomura, S.
    Tsusaka, Y.
    Nakano, S.
    Kosaka, N.
    Yamamoto, K.
    Kagoshima, Y.
    11TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY (XRM2012), 2013, 463
  • [48] X-RAY REAL-TIME IMAGING FOR WELD INSPECTION - IIW 3RD PROGRESS REPORT
    HALMSHAW, R
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1987, 29 (06): : 426 - 428
  • [49] X-RAY REAL-TIME IMAGING FOR WELD INSPECTION - IIW 2ND PROGRESS REPORT
    不详
    BRITISH JOURNAL OF NON-DESTRUCTIVE TESTING, 1987, 29 (01): : 22 - 23
  • [50] X-ray real-time imaging (XRTI) for weld inspection: 3rd progress report
    Anon
    Welding in the World, Le Soudage Dans Le Monde, 1988, 26 (5-6): : 100 - 107