In silico study of the electronic portal imaging devices sensitivity to parotid glands shrinkage during radiotherapy for nasopharyngeal cases

被引:0
|
作者
Alzahrani H.M. [1 ]
机构
[1] Radiology Technology, College of Applied Medical Sciences, Taibah University, Medina
关键词
Anatomical changes; Dosimetry; EGSnrc; EPID; Monte Carlo simulation; Parotid gland shrinkage;
D O I
10.1007/s43994-023-00103-z
中图分类号
学科分类号
摘要
This computational investigation examines the capability of electronic portal imaging devices (EPIDs) in detecting anatomical changes during radiation therapy. A photon beam for 6 MV was simulated using compliant phase-space files via BEAMnrc (an EGSnrc user code). Initially, the dose calculation was carried out using DOSXYZnrc, an EGSnrc user code, on a water-based calibration phantom made of water. Phantoms, constructed utilizing patient computed tomography data, were subsequently used to simulate clinically relevant parotid gland (PG) shrinkage through image deformation using ImSimQA software. Two EPID geometries were implemented; a simple water slab, and a comprehensive multi-layer representation of the EPID (referred to as the 17-slab model). Using a 1%/1 mm gamma index the 17-slab geometry was sensitive to volume reductions in the PG ≥ − 26% from its original volume, while the water slab detected volume reduction of ≥ − 28.5%. In a clinical setting, replanning of head and neck patients is initiated when a reduction of 24–30% in PG volume is detected through cone-beam computed tomography. The sensitivity index, indicative of the signal to error ratio between the reference and evaluated images, showed an increase as the gland volume decreased for both models. Notably, the 17-slab model consistently more sensitive than the water slab. This computational study highlights the prospective use of EPIDs in monitoring and detecting clinically significant volume changes in the PG during radiation treatment. Advances in knowledge: While EPIDs are frequently employed for patient setup and alignment, this computational work constructed a virtual EPID to assess its detection abilities for the anatomical changes in the PG due to radiation exposure in head and neck cancer cases. © The Author(s) 2024.
引用
收藏
页码:279 / 289
页数:10
相关论文
共 38 条
  • [21] Feasibility study of patient positioning verification in electron beam radiotherapy with an electronic portal imaging device (EPID)
    Ramm, U.
    Koehn, J.
    Dominguez, R. Rodriguez
    Licher, J.
    Koch, N.
    Kara, E.
    Scherf, C.
    Roedel, C.
    Weiss, C.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (02): : 215 - 220
  • [22] Feasibility study of an electronic portal imaging based in vivo dose verification system for prostate stereotactic body radiotherapy
    Yedekci, Yagiz
    Biltekin, Fatih
    Ozyigit, Gokhan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 204 - 209
  • [23] Temporal Evolution of Parotid Volume and Parotid Apparent Diffusion Coefficient in Nasopharyngeal Carcinoma Patients Treated by Intensity-Modulated Radiotherapy Investigated by Magnetic Resonance Imaging: A Pilot Study
    Juan, Chun-Jung
    Cheng, Cheng-Chieh
    Chiu, Su-Chin
    Jen, Yee-Min
    Liu, Yi-Jui
    Chiu, Hui-Chu
    Kao, Hung-Wen
    Wang, Chih-Wei
    Chung, Hsiao-Wen
    Huang, Guo-Shu
    Hsu, Hsian-He
    PLOS ONE, 2015, 10 (08):
  • [24] Development of Artificial Intelligence as a Conversion Tool for Cine Electronic Portal Imaging Device Images to Radiotherapy Dosimetry: Preliminary Study
    Ramadhan M.M.
    Wibowo W.E.
    Pawiro S.A.
    Iranian Journal of Medical Physics, 2022, 19 (05): : 296 - 304
  • [25] The use of electronic portal imaging to verify patient position during intensity-modulated radiotherapy delivered by the dynamic MLC technique
    Fielding, AL
    Evans, PM
    Clark, CH
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (04): : 1225 - 1234
  • [26] Diffusion tensor imaging study on radiation-induced brain injury in nasopharyngeal carcinoma during and after radiotherapy
    Chen, Wangsheng
    Qiu, Shijun
    Li, Jianjun
    Hong, Lan
    Wang, Fen
    Xing, Zengbao
    Li, Changqing
    TUMORI, 2015, 101 (05) : 487 - 490
  • [27] Predicting Lung Tumor Shrinkage During Radiotherapy Seen in a Longitudinal MR Imaging Study Via a Deep Learning Algorithm
    Wang, C.
    Hu, Y.
    Rimner, A.
    Tyagi, N.
    Yorke, E.
    Mageras, G.
    Deasy, J.
    Zhang, P.
    MEDICAL PHYSICS, 2018, 45 (06) : E582 - E582
  • [28] Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study
    de Koste, John R. van Sornsen
    Cuijpers, Johan P.
    de Geest, Frank G. M.
    Lagerwaard, Frank J.
    Slotman, Ben J.
    Senan, Suresh
    RADIATION ONCOLOGY, 2007, 2 (1)
  • [29] Verifying 4D gated radiotherapy using time-integrated electronic portal imaging: a phantom and clinical study
    John R van Sörnsen de Koste
    Johan P Cuijpers
    Frank GM de Geest
    Frank J Lagerwaard
    Ben J Slotman
    Suresh Senan
    Radiation Oncology, 2
  • [30] Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer
    Erridge, SC
    Seppenwoolde, Y
    Muller, SH
    van Herk, M
    De Jaeger, K
    Belderbos, JSA
    Boersma, LJ
    Lebesque, JV
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (01) : 75 - 85