EXPERIMENTAL-DETERMINATION OF FRICTION CHARACTERISTICS AT THE TRABECULAR BONE POROUS-COATED METAL INTERFACE IN CEMENTLESS IMPLANTS

被引:199
|
作者
SHIRAZIADL, A [1 ]
DAMMAK, M [1 ]
PAIEMENT, G [1 ]
机构
[1] SACRE COEUR HOSP,MONTREAL H3C 3A7,PQ,CANADA
来源
关键词
D O I
10.1002/jbm.820270205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An apparatus was developed to measure load-displacement friction properties at the cancellous bone/porous-coated metal plate interface. Bone cubes were obtained from different proximal regions of four resurfaced cadaveric tibiae. Three different porous-surfaced metal plates (one fiber mesh and two bead) and a smooth-surfaced metal plate were used. In the presence of a constant normal contact pressure (0.10, 0.15, or 0.25 MPa), a variable tangential load up to the maximum resistance of the interface was applied and both relative normal and tangential displacements were recorded. Repetitive and fatigue loadings were also considered. Measured results show that the interface friction curve is highly nonlinear, exhibiting large relative tangential displacements in the range of 50-400 mum before the maximum load is reached. Relative displacements in the normal direction remain below 10 mum. The maximum resistance in friction is independent of the bone excision site, type of porous-surfaced metal plate, magnitude of normal load, placement of bone cubes on metal plates or vice versa, repetition of applied load, and conservation period of bone cubes in saline solution. The smooth-surfaced metal plate has significantly smaller friction resistance than porous-coated ones. The fatigue loading ot up to 4000 cycles at 1 Hz, in the presence of 0.25 MPa contact pressure, slightly decreases the interface friction coefficient. Finally, the initial secant stiffness of the interface at 75% of the maximum resistance load is found to be larger for the bone cubes from the lateral and medial regions and for the metal plate with smooth surface.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 47 条
  • [41] X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants
    Savarino, L
    Stea, S
    Granchi, D
    Donati, ME
    Cervellati, M
    Moroni, A
    Paganetto, G
    Pizzoferrato, A
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1998, 9 (02) : 109 - 115
  • [42] INTERFACE MECHANICS AND HISTOMORPHOMETRIC ANALYSIS OF HYDROXYAPATITE-COATED AND POROUS GLASS-CERAMIC IMPLANTS IN CANINE BONE
    NIMB, L
    JENSEN, JS
    GOTFREDSEN, K
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (12): : 1477 - 1482
  • [43] COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF HYDROXYAPATITE-COATED AND ALUMINA-COATED METAL IMPLANTS
    INADOME, T
    HAYASHI, K
    NAKASHIMA, Y
    TSUMURA, H
    SUGIOKA, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (01): : 19 - 24
  • [44] Examination of the bone-metal interface of titanium implants coated by the microwave plasma chemical vapor deposition method
    Rupprecht, S
    Bloch, A
    Rosiwal, S
    Neukam, FW
    Wiltfang, J
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2002, 17 (06) : 778 - 785
  • [45] Experimental Research on Friction Characteristics of DLC Coated Cylinder Block/Valve Plate Interface in Aerospace Integrated Motor Pumps
    Lyu Dingchong
    Fu Jian
    Ci Ke
    Zhao Jiangao
    Zhao Shoujun
    2023 ASIA-PACIFIC INTERNATIONAL SYMPOSIUM ON AEROSPACE TECHNOLOGY, VOL II, APISAT 2023, 2024, 1051 : 1141 - 1156
  • [46] POROUS-COATED UNCEMENTED COMPONENTS IN EXPERIMENTAL TOTAL HIP-ARTHROPLASTY IN DOGS - EFFECT OF PLASMA-SPRAYED CALCIUM-PHOSPHATE COATINGS ON BONE INGROWTH
    JASTY, M
    RUBASH, HE
    PAIEMENT, GD
    BRAGDON, CR
    PARR, J
    HARRIS, WH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1992, (280) : 300 - 309
  • [47] Porous titanium-coated polyetheretherketone implants exhibit an improved bone-implant interface: an in vitro and in vivo biochemical, biomechanical, and histological study
    Cheng, Boyle C.
    Koduri, Sravanthi
    Wing, Charles A.
    Woolery, Natalie
    Cook, Daniel J.
    Spiro, Robert C.
    MEDICAL DEVICES-EVIDENCE AND RESEARCH, 2018, 11 : 391 - 402