EXPERIMENTAL-DETERMINATION OF FRICTION CHARACTERISTICS AT THE TRABECULAR BONE POROUS-COATED METAL INTERFACE IN CEMENTLESS IMPLANTS

被引:199
|
作者
SHIRAZIADL, A [1 ]
DAMMAK, M [1 ]
PAIEMENT, G [1 ]
机构
[1] SACRE COEUR HOSP,MONTREAL H3C 3A7,PQ,CANADA
来源
关键词
D O I
10.1002/jbm.820270205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An apparatus was developed to measure load-displacement friction properties at the cancellous bone/porous-coated metal plate interface. Bone cubes were obtained from different proximal regions of four resurfaced cadaveric tibiae. Three different porous-surfaced metal plates (one fiber mesh and two bead) and a smooth-surfaced metal plate were used. In the presence of a constant normal contact pressure (0.10, 0.15, or 0.25 MPa), a variable tangential load up to the maximum resistance of the interface was applied and both relative normal and tangential displacements were recorded. Repetitive and fatigue loadings were also considered. Measured results show that the interface friction curve is highly nonlinear, exhibiting large relative tangential displacements in the range of 50-400 mum before the maximum load is reached. Relative displacements in the normal direction remain below 10 mum. The maximum resistance in friction is independent of the bone excision site, type of porous-surfaced metal plate, magnitude of normal load, placement of bone cubes on metal plates or vice versa, repetition of applied load, and conservation period of bone cubes in saline solution. The smooth-surfaced metal plate has significantly smaller friction resistance than porous-coated ones. The fatigue loading ot up to 4000 cycles at 1 Hz, in the presence of 0.25 MPa contact pressure, slightly decreases the interface friction coefficient. Finally, the initial secant stiffness of the interface at 75% of the maximum resistance load is found to be larger for the bone cubes from the lateral and medial regions and for the metal plate with smooth surface.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 47 条
  • [31] GLOBAL MECHANICAL-PROPERTIES OF TRABECULAR BONE - EXPERIMENTAL-DETERMINATION AND PREDICTION FROM A STRUCTURAL MODEL
    KLEVER, FJ
    KLUMPERT, R
    GROOTENBOER, HJ
    VANCAMPEN, DH
    PAULY, T
    JOURNAL OF BIOMECHANICS, 1985, 18 (07) : 522 - 522
  • [32] THE EFFECT OF PARTIAL COATING WITH HYDROXYAPATITE ON BONE REMODELING IN RELATION TO POROUS-COATED TITANIUM-ALLOY DENTAL IMPLANTS IN THE DOG
    PILLIAR, RM
    DEPORTER, DA
    WATSON, PA
    PHAROAH, M
    CHIPMAN, M
    VALIQUETTE, N
    CARTER, S
    DEGROOT, K
    JOURNAL OF DENTAL RESEARCH, 1991, 70 (10) : 1338 - 1345
  • [33] Cementless Porous-Coated Metaphyseal Sleeves Used for Bone Defects in Revision Total Knee Arthroplasty: Short- to Mid-Term Outcomes
    Shen, Junmin
    Zhang, Ti
    Zhang, Yanchao
    Dong, Yu
    Zhou, Yonggang
    Guo, Lingfei
    ORTHOPAEDIC SURGERY, 2023, 15 (02) : 488 - 495
  • [34] BONE INGROWTH ANALYSIS AND INTERFACE EVALUATION OF HYDROXYAPATITE-COATED VERSUS UNCOATED TITANIUM POROUS BONE IMPLANTS
    MORONI, A
    CAJA, VL
    SABATO, C
    EGGER, EL
    GOTTSAUNERWOLF, F
    CHAO, EYS
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (6-7) : 411 - 416
  • [35] BONE-MINERAL DENSITY AROUND FEMORAL STEMS - DXA MEASUREMENTS IN 22 POROUS-COATED IMPLANTS AFTER 5 YEARS
    PETERSEN, MB
    KOLTHOFF, N
    EIKEN, P
    ACTA ORTHOPAEDICA SCANDINAVICA, 1995, 66 (05): : 432 - 434
  • [36] Friction properties at the bone-metal interface: Comparison of four different porous metal surfaces
    Dammak, M
    ShiraziAdl, A
    Schwartz, M
    Gustavson, L
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1997, 35 (03): : 329 - 336
  • [37] EXPERIMENTAL-DETERMINATION OF THE ORTHOGONAL MECHANICAL-PROPERTIES AND DENSITY OF CANINE TRABECULAR BONE FROM LUMBAR VERTEBRAL BODIES
    TSAI, E
    GOLDSTEIN, SA
    CLINICAL RESEARCH, 1988, 36 (06): : A926 - A926
  • [38] THE EFFECTS OF THERAPEUTIC DOSES OF IRRADIATION ON EXPERIMENTAL BONE-GRAFT INCORPORATION OVER A POROUS-COATED SEGMENTAL DEFECT ENDOPROSTHESIS
    CHIN, HC
    FRASSICA, FJ
    MARKEL, MD
    FRASSICA, D
    SIM, FH
    CHAO, EYS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (289) : 254 - 266
  • [39] Comparison of bone-implant interface shear strength of hydroxyapatite- coated and alumina-coated metal implants
    Department of Orthopaedic Surgery, Faculty of Medicine, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812, Japan
    J. BIOMED. MATER. RES., 1 (19-24):
  • [40] X-ray diffraction of bone at the interface with hydroxyapatite-coated versus uncoated metal implants
    L SAVARINO
    S STEA
    D GRANCHI
    M. E DONATI
    M CERVELLATI
    A MORONI
    G PAGANETTO
    A PIZZOFERRATO
    Journal of Materials Science: Materials in Medicine, 1998, 9 : 109 - 115