EXPERIMENTAL-DETERMINATION OF FRICTION CHARACTERISTICS AT THE TRABECULAR BONE POROUS-COATED METAL INTERFACE IN CEMENTLESS IMPLANTS

被引:199
|
作者
SHIRAZIADL, A [1 ]
DAMMAK, M [1 ]
PAIEMENT, G [1 ]
机构
[1] SACRE COEUR HOSP,MONTREAL H3C 3A7,PQ,CANADA
来源
关键词
D O I
10.1002/jbm.820270205
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An apparatus was developed to measure load-displacement friction properties at the cancellous bone/porous-coated metal plate interface. Bone cubes were obtained from different proximal regions of four resurfaced cadaveric tibiae. Three different porous-surfaced metal plates (one fiber mesh and two bead) and a smooth-surfaced metal plate were used. In the presence of a constant normal contact pressure (0.10, 0.15, or 0.25 MPa), a variable tangential load up to the maximum resistance of the interface was applied and both relative normal and tangential displacements were recorded. Repetitive and fatigue loadings were also considered. Measured results show that the interface friction curve is highly nonlinear, exhibiting large relative tangential displacements in the range of 50-400 mum before the maximum load is reached. Relative displacements in the normal direction remain below 10 mum. The maximum resistance in friction is independent of the bone excision site, type of porous-surfaced metal plate, magnitude of normal load, placement of bone cubes on metal plates or vice versa, repetition of applied load, and conservation period of bone cubes in saline solution. The smooth-surfaced metal plate has significantly smaller friction resistance than porous-coated ones. The fatigue loading ot up to 4000 cycles at 1 Hz, in the presence of 0.25 MPa contact pressure, slightly decreases the interface friction coefficient. Finally, the initial secant stiffness of the interface at 75% of the maximum resistance load is found to be larger for the bone cubes from the lateral and medial regions and for the metal plate with smooth surface.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 47 条
  • [1] MINERAL APPOSITION RATES OF HUMAN CANCELLOUS BONE AT THE INTERFACE OF POROUS-COATED IMPLANTS
    BLOEBAUM, RD
    BACHUS, KN
    MOMBERGER, NG
    HOFMANN, AA
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1994, 28 (05): : 537 - 544
  • [2] Trabecular bone adaptation to variations in porous-coated implant topology
    Guldberg, RE
    Richards, M
    Caldwell, NJ
    Kuelske, CL
    Goldstein, SA
    JOURNAL OF BIOMECHANICS, 1997, 30 (02) : 147 - 153
  • [3] The effect of bone compaction on early fixation of porous-coated implants
    Green, JR
    Nemzek, JA
    Arnoczky, SP
    Johnson, LL
    Balas, MS
    JOURNAL OF ARTHROPLASTY, 1999, 14 (01): : 91 - 97
  • [4] Porous-Coated Cementless Acetabular Components Without Bulk Bone Graft in Revision Surgery
    Ito, Hiroshi
    Tanino, Hiromasa
    Yamanaka, Yasuhiro
    Sato, Tatsuya
    Minami, Akio
    Matsuno, Takeo
    JOURNAL OF ARTHROPLASTY, 2010, 25 (08): : 1307 - 1310
  • [5] ENHANCED STABILIZATION OF POROUS-COATED METAL IMPLANTS WITH TRICALCIUM PHOSPHATE GRANULES
    ESCHENROEDER, HC
    MCLAUGHLIN, RE
    REGER, SI
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (216) : 234 - 246
  • [6] Progression of human bone ingrowth into porous-coated implants - Rate of bone ingrowth in humans
    Hofmann, AA
    Bloebaum, RD
    Bachus, KN
    ACTA ORTHOPAEDICA SCANDINAVICA, 1997, 68 (02): : 161 - 166
  • [7] DEMINERALIZED BONE-MATRIX IN THE STABILIZATION OF POROUS-COATED IMPLANTS IN BONE DEFECTS IN RABBITS
    SHEN, WJ
    CHUNG, KC
    WANG, GJ
    BALIAN, G
    MCLAUGHLIN, RE
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1993, (293) : 346 - 352
  • [8] Bidirectional friction study of cancellous bone-porous coated metal interface
    Hashemi, A
    ShiraziAdl, A
    Dammak, M
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 33 (04): : 257 - 267
  • [9] Acid-etched microtexture for enhancement of bone growth into porous-coated implants
    Hacking, SA
    Harvey, EJ
    Tanzer, M
    Krygier, JJ
    Bobyn, JD
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (08): : 1182 - 1189
  • [10] Effect of noninvasive low intensity ultrasound on bone growth into porous-coated implants
    Tanzer, M
    Harvey, E
    Kay, A
    Morton, P
    Bobyn, JD
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1996, 14 (06) : 901 - 906