COMPARISON OF INFRARED AND HELIUM-NEON LASERS IN THE MEASUREMENT OF BLOOD-FLOW IN HUMAN SKIN BY THE LASER-DOPPLER TECHNIQUE

被引:0
|
作者
COULSON, ML [1 ]
HAYES, NA [1 ]
FOREMAN, JC [1 ]
机构
[1] UNIV LONDON UNIV COLL,DEPT PHARMACOL,GOWER ST,LONDON WC1E 6BT,ENGLAND
来源
SKIN PHARMACOLOGY | 1992年 / 5卷 / 02期
关键词
LASER-DOPPLER; BLOOD FLOW; HUMAN SKIN; HISTAMINE;
D O I
暂无
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Histamine-induced changes in blood flow in normal human skin were assessed by laser-Doppler velocimetry using 2 lasers of different wavelengths: 780 nm infrared and 633 nm helium-neon. The visible flare response in skin was also measured by planimetry. Laser-Doppler velocimetry was shown to detect both the magnitude of the change in blood flow caused by histamine and also the extent of the changes in the skin. Both parameters were related to the dose of histamine, which ranged between 25 and 750 pmol/site. There was good correlation between the magnitude of the histamine-induced blood flow change and the extent of the response. The flare induced by histamine and measured by planimetry was similar in extent to the blood flow change, recorded by laser-Doppler velocimetry. No difference in either the magnitude or the extent of blood flow changes in response to histamine, as measured by laser-Doppler velocimetry, were found when lasers of different wavelengths were used.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [31] INFLUENCE OF MENTAL STRESS ON PERIPHERAL SKIN BLOOD-FLOW AS DETERMINED BY LASER-DOPPLER FLOWMETER
    GOBEL, S
    CURIO, I
    SCHACHINGER, H
    RUDDEL, H
    VERHALTENSTHERAPIE, 1995, 5 : A66 - A66
  • [32] BLOOD-FLOW IN THE HUMAN ACHILLES-TENDON ASSESSED BY LASER-DOPPLER FLOWMETRY
    ASTROM, M
    WESTLIN, N
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (02) : 246 - 252
  • [33] HUMAN GASTRIC-MUCOSAL BLOOD-FLOW BY ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    GANA, TJ
    SOENEN, GM
    KOO, J
    GASTROINTESTINAL ENDOSCOPY, 1989, 35 (02) : 152 - 153
  • [34] EVALUATION OF THE MEASUREMENT OF GASTRIC-MUCOSAL BLOOD-FLOW BY LASER-DOPPLER VELOCIMETRY IN RATS
    SAITA, H
    MURAKAMI, M
    SEKI, M
    MIYAKE, T
    GASTROENTEROLOGY, 1984, 86 (05) : 1228 - 1228
  • [35] MEASUREMENT OF AIRWAY WALL BLOOD-FLOW IN SHEEP BY LASER-DOPPLER FLOWMETRY - INTERPRETATION AND PROBLEMS
    GODDEN, DJ
    WAGNER, EM
    PARE, PD
    MITZNER, W
    BAILE, EM
    JOURNAL OF APPLIED PHYSIOLOGY, 1991, 70 (02) : 641 - 649
  • [36] LASER DOPPLER MEASUREMENT OF SKIN BLOOD-FLOW IN NEWBORN-INFANTS
    STROMBERG, B
    RIESENFELD, T
    SEDIN, G
    PEDIATRIC RESEARCH, 1985, 19 (10) : 1128 - 1128
  • [37] LASER DOPPLER MEASUREMENT OF SKIN BLOOD-FLOW IN NEWBORN-INFANTS
    STROMBERG, B
    RIESENFELD, T
    SEDIN, G
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1984, 3 (3-4): : 434 - 434
  • [38] LOCAL CHOROIDAL BLOOD-FLOW IN THE CAT BY LASER-DOPPLER FLOWMETRY
    RIVA, CE
    CRANSTOUN, SD
    MANN, RM
    BARNES, GE
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (02) : 608 - 618
  • [39] EVALUATION OF LASER-DOPPLER FLOWMETRY AS A MEASURE OF TISSUE BLOOD-FLOW
    SMITS, GJ
    ROMAN, RJ
    LOMBARD, JH
    JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) : 666 - 672
  • [40] BLOOD-FLOW OF MORPHEA PLAQUES AS MEASURED BY LASER-DOPPLER FLOWMETRY
    SERUP, J
    KRISTENSEN, JK
    ARCHIVES OF DERMATOLOGICAL RESEARCH, 1984, 276 (05) : 322 - 325