MEASUREMENT OF AIRWAY WALL BLOOD-FLOW IN SHEEP BY LASER-DOPPLER FLOWMETRY - INTERPRETATION AND PROBLEMS

被引:12
|
作者
GODDEN, DJ
WAGNER, EM
PARE, PD
MITZNER, W
BAILE, EM
机构
[1] UNIV BRITISH COLUMBIA,ST PAULS HOSP,PULM RES LAB,1081 BURRARD ST,VANCOUVER V6Z 1Y6,BC,CANADA
[2] JOHNS HOPKINS UNIV,FRANCIS SCOTT KEY MED CTR,DEPT MED,DIV PULM MED,BALTIMORE,MD 21205
关键词
BRONCHIAL AND TRACHEAL BLOOD FLOW; BRONCHIAL ARTERY PERFUSION; BRONCHOSCOPY;
D O I
10.1152/jappl.1991.70.2.641
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
We have used laser-Doppler flowmetry (LDF), a technique that detects movement of erythrocytes, to measure tracheal and bronchial wall blood flow in anesthetized openchest sheep. LDF derives continuous measurements noninvasively, although fiber-optic bronchoscopy is necessary to introduce the LDF probe into the airways. The response of the LDF flow signals at four regions of the airway walls to varying bronchial arterial flow rates was examined in both live and dead sheep by cannulation and subsequent perfusion of the common bronchial artery at different flow rates by use of a roller pump. In the live sheep, variations in bronchial arterial blood flow resulted in variations in LDF signals in the principal bronchus and in lobar and segmental bronchi but not in the trachea. In the dead sheep, variations in bronchial arterial blood flow resulted in variations in LDF signals in all four regions. Within regions, the average response of the LDF signals to varying bronchial blood flow rates was approximately linear in both live and dead sheep, but considerable site-to-site variation in response was observed. In the live sheep, significant LDF signals were observed when the bronchial arterial flow was set to zero and when the bronchial artery was perfused with dextran solution, which would in theory be expected to produce no LDF signal. A small LDF signal was also detected under zero flow conditions in the dead sheep. These observations suggest that the LDF technique, in addition to detecting blood flow from the bronchial artery, also detects background noise and/or collateral circulation. The residual signal at zero flow and after death and the site-to-site variability represent major problems that preclude accurate measurement of changes in airway blood flow with this technique. These data suggest that in its present form LDF will not prove useful in the measurement of airway wall blood flow during bronchoscopy.
引用
收藏
页码:641 / 649
页数:9
相关论文
共 50 条
  • [1] CALIBRATION OF LASER-DOPPLER FLOWMETRY FOR MEASUREMENT OF GINGIVAL BLOOD-FLOW
    SASANO, T
    SHOJI, N
    KURIWADA, S
    SANJO, D
    JOURNAL OF PERIODONTAL RESEARCH, 1995, 30 (04) : 298 - 301
  • [2] LASER-DOPPLER FLOWMETRY AS A MEASUREMENT OF COLONIC MUCOSAL BLOOD-FLOW
    HOLTZMULLER, K
    DUNKLEBERG, J
    MAYDONOVITCH, CL
    WONG, RKH
    GASTROINTESTINAL ENDOSCOPY, 1989, 35 (02) : 181 - 181
  • [3] CHOROIDAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY
    RIVA, CE
    PETRIG, BL
    OPTICAL ENGINEERING, 1995, 34 (03) : 746 - 752
  • [4] THE CHARACTERISTICS OF LASER-DOPPLER FLOWMETRY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW
    FUKUDA, O
    ENDO, S
    KUWAYAMA, N
    HARADA, J
    TAKAKU, A
    NEUROSURGERY, 1995, 36 (02) : 358 - 364
  • [5] INTRAOPERATIVE MEASUREMENT OF CEREBRAL AND TUMOR BLOOD-FLOW WITH LASER-DOPPLER FLOWMETRY
    ARBIT, E
    DIRESTA, GR
    BEDFORD, RF
    SHAH, NK
    GALICICH, JH
    NEUROSURGERY, 1989, 24 (02) : 166 - 170
  • [6] LASER-DOPPLER FLOWMETRY FOR ESTIMATING LIVER BLOOD-FLOW
    ARVIDSSON, D
    SVENSSON, H
    HAGLUND, U
    AMERICAN JOURNAL OF PHYSIOLOGY, 1988, 254 (04): : G471 - G476
  • [7] THE CHARACTERISTICS OF LASER-DOPPLER FLOWMETRY FOR THE MEASUREMENT OF REGIONAL CEREBRAL BLOOD-FLOW - COMMENT
    BAKER, CJ
    SOLOMON, RA
    NEUROSURGERY, 1995, 36 (02) : 364 - 364
  • [8] VALIDATION OF LASER-DOPPLER FLOWMETRY IN MEASUREMENT OF SPINAL-CORD BLOOD-FLOW
    LINDSBERG, PJ
    ONEILL, JT
    PAAKKARI, IA
    HALLENBECK, JM
    FEUERSTEIN, G
    AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (02): : H674 - H680
  • [9] CONTINUOUS MEASUREMENT OF GASTRIC BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY DURING GASTROSCOPY
    CHRISTOFORIDIS, EC
    HOVENDAL, C
    BJERRING, P
    KRUSE, A
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1989, 24 (01) : 16 - 20
  • [10] EVALUATION OF LASER-DOPPLER FLOWMETRY AS A MEASURE OF TISSUE BLOOD-FLOW
    SMITS, GJ
    ROMAN, RJ
    LOMBARD, JH
    JOURNAL OF APPLIED PHYSIOLOGY, 1986, 61 (02) : 666 - 672